Permit Review Detail
Review Status: Completed
Review Details: DEVELOPMENT PLAN
Permit Number - D10-0020
Review Name: DEVELOPMENT PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2010 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/04/2010 | RONALD BROWN | ADA | REVIEW | Passed | |
| 06/09/2010 | FERNE RODRIGUEZ | COT NON-DSD | TUCSON POLICE DEPARTMENT | Approved | I have no issues with this request at this time. ** The placement of the playground is not in front of parking spaces so the safety factor is not an issue for out of control vehicles pulling into parking spaces.** CSO Becky Noel #37968 Tucson Police Dept 837-7428 |
| 06/10/2010 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: June 10, 2010 SUBJECT: Academy Del Sol Development Plan- Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 6740 S Santa Clara Ave, T15S R13E Sec14, Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: D10-0020 SUMMARY: Engineering Division of Planning Development Services Department has received and reviewed the proposed development plan, Sheet C1.0. Engineering Division does not recommend approval of the development plan at this time. The following items need to be addressed: DEVELOPMENT PLAN: 1) DS Sec.2-05.2.1.D: A small, project-location map shall be drawn on the first sheet of the development plan, preferably in the upper right corner. The map should cover approximately one (1) square mile, be drawn at a minimum scale of 3" = 1 mile, and provide the following information. a. Show the subject property approximately centered within the one (1) square mile area. b. Identify conditions within the square mile area, such as major streets and watercourses (El Vado Wash). c. Section, township, and range; section corners; north arrow; and the scale will be labeled. 2) DS Sec.2-05.2.1.G: Revise the title block information to provide a brief legal description of the property. Revise the reference to "Site Plan" on both the title block and scale label to reference a "Development Plan." 3) DS Sec.2-05.2.1.K: The development plan number (D10-0020) must be added to the lower right hand corner of the plan. 4) DS Sec.2-05.2.2.A.1: Revise the Owner Information Section to include the telephone number of the primary property owner of the site. 5) DS Sec.2-05.2.2.C.1.a: Provide the following note on the development plan; "The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall." 6) DS Sec.2-05.2.2.C.1.b: Provide the following note on the development plan; "Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this development plan." 7) DS Sec.2-05.2.2.C.2.a: Provide the following note on the development plan to read; "The subject parcel is affected by the City of Tucson Floodplain Regulations per the mapped FEMA Zone AE Special Flood Hazard Area as shown on the Flood Insurance Rate Map (FIRM), Community-Panel No. 040076 C 2238K, effective date February 8, 1999 revised LOMR dated 24JUL00." 8) DS Sec.2-05.2.2.C.2.b: Provide the following note on the development plan to read; "A floodplain use permit will be required for any future work proposed within the mapped FEMA Zone AE 100-year floodplain limits of the regulatory wash as shown on the Development Plan." 9) DS Sec.2-05.2.2.E: Provide the following note on the development plan; "Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public." 10) DS Sec.2-05.2.3.C: Revise the development plan to provide or correct the following information for the existing public right-of-way. a. All existing roadways need to be labeled as "Public" not private. b. Remove the reference to the "MS&R" on all existing roadways. c. Dimension the width of existing paving, curbs, curb cuts and sidewalks. 11) DS Sec.2-05.2.3.F: Revise the development plan to clearly label the Improvement Plan # reference for the existing drainage facilities under Santa Clara Ave. 12) DS Sec.2-05.2.3.I: Revise the development plan to label and dimension the 100-year Zone AE floodplain limits, water surface elevation (WSEL) and Q100 discharge value of the regulatory El Vado Wash. The development plan will require a civil engineering stamp to certify the location of the FEMA floodplain and WSEL cross sections. 13) DS Sec.2-05.2.4.K: Refer to comments from Ron Brown, RA Structural Plans Examiner for all handicap accessibility comments that may be associated with this project. 14) DS Sec.2-05.2.4.R: Revise the development plan to label and dimension the existing Sight Visibility Triangles (near and far side) for all PAAL access points and roadway intersections. Refer to DS Sec.3-01.5.1 for SVT procedures and criteria. GENERAL COMMENTS: Please provide a revised development plan that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the development plan and review. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 06/15/2010 | JOHN BEALL | COT NON-DSD | URBAN PLANNING & DESIGN | Denied | CDRC Review Planning and Development Services Dept., Community Planning Review D10-0020, Academy del Sol, 1st submittal Comments Due: 6/18/10 Comments Submitted: 6/11/10 Items reviewed: Development Plan SE-09-11; PDP and ZE Decision Letter Comments: 1. Please list the Special Exception (SE) conditions on the Development Plan. 2. Condition #9 limits the number of students to 100. The parking calculations indicate there will be 120 students. Please clarify on the plans that only 100 students are permitted. Reviewed by: J. Hershenhorn, 6/11/10 F:\Shardir\UPDfiles\Development Review\CASE_REVIEW\CDRC\2010 Cases\D10-0020.doc |
| 06/16/2010 | RONALD BROWN | ZONING HC | REVIEW | Denied | General Statement: After a second analysis of the project, it is found that there is not a change of occupancy, education is education. The following comments are based upon the modifications made that are required to comply with the 2006 IBC. 1. Please provide a large scale detail of the newly proposed accessible loading zoneshowing all critical accessible code compliance requirements: dimensions, a 5' wide access aisle adjacent to a 20'x 8' parking space as per ICC (ANSI 117.1) Section 503 , ramps, access to accessible route, surface slope conditions and etc. a. Please delete all references (note 8) to COT DOT Std Detail 207. This is for COT use only for right of way construction. All accessible requirements are as per the 2006 IBC, Chapter 11 and ICC (ANSI 117.1). 2. As requirerd by Zoning, please provide an accessible route and ramps to building 3. All ramps are to comply with Section 405. 3. For all new concrete sidewalk construction please show accessible route slope requirements as per ICC (ANAI 117.1) Section 403.3. END OF REVIEW |
| 06/17/2010 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: D10-0020 Academy Del Sol Development Plan TRANSMITTAL: 06/17/2010 DUE DATE: 06/18/2010 COMMENTS: 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 06/03/11. 2. DS 2-01.2.4 A title block shall be provided in the lower right quadrant of each sheet. 3. DS 2-01.2.5 A three (3) inch by five (5) inch space shall be reserved in the lower right quadrant of each sheet for an approval stamp. 4. DS 2-01.2.6 A small, project-location map shall be provided in the upper right corner of the cover sheet 5. DS 2-01.2.7 The north arrow, contour interval, and scale as applicable to each sheet should be placed together in the upper right corner of each sheet. 6. DS 2-01.3.1 The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided. 7. DS 2-01.3.2 The title block shall include the following information. A. The proposed name of the project or if there is no name, the proposed tenant's name. B. A brief legal description C. The administrative street address. D. Page number and number of pages. 8. DS 2-01.3.3 Relevant case numbers (development package document-D10-0020 and special exception -SE-09-11 case numbers) shall be provided adjacent to the title block on each sheet. 9. DS 2-01.3.4 The project-location map shall cover approximately one (1) square mile, be drawn at a minimum scale of 3" = 1 mile, and provide the following information. A. Show the subject property approximately centered within the one (1) square mile area. B. Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property. C. Section, township, and range; section corners; north arrow; and the scale will be labeled. 10. DS 2-01.3.7 General Notes. The following general notes are required. Additional notes specific to each plan are required where applicable. A. Zoning and Land Use Notes. 1. Identify the existing and proposed use of the property as classified per the Land Use Code. List all Land Use Code sections each proposed use is subject to. a. Religious Use "12" b. Educational Use: Elementary and Secondary Schools "11" 2. List special exceptions, zoning variances, zoning and development standard modifications, overlay zones, and other reviews that are applicable to the project. a. List the special exception by case number, in lower right corner of each sheet. As a general note provide the case number, date of approval, what was approved, and the conditions of approval. Provide a separate letter clearly indicating how conditions of approval for the special exception have been meet. 3. This project has two uses with different FAR requirements. Provide FAR calculations for both uses. 4. Provide lot coverage percentages for both uses. 11. DS 2-01.3.8.B All easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. 12. DS 2-01.3.8.H.2 Show existing sight visibility triangles 13. DS 2-01.3.8.H.1 Clearly indicate the direction of travel for the PAAL exiting onto Calle Aragon closest to Santa Clara. 14. DS 2-01.3.8.H.5.a The number of allowed students per the special exception condition #9 is 100. Revise note, parking calculations, and bicycle parking calculations. 15. DS 2-01.3.8.H.5.c The indicated loading zone appears to be located in a gravel area which is not an approved location.. The educational use may require up to two loading zones that meets the requirements of LUC. Clearly indicate the use of buildings #2 and #3. If building #3 is used for educational use a loading zone will be required for both buildings #4 and #3. 16. DS 2-01.3.8.H.d Please provide a plan view detail of the proposed class 2 bicycle parking spaces. Single rack spaces placed in a row will allow a minimum of seventy -two (72) inch length per bicycle parking space and a minimum of thirty (30) inches between outer spaces of racks. A five (5) foot wide access aisle measured from the front or rear of the seventy-two (72) inch long parking space will be provided beside each row. Lighting will be provided such that all facilities are thoroughly illuminated and visible from adjacent sidewalks, parking lots, or buildings, during working hours. The surface of the facility can be surfaced the same as for motor vehicle parking or with a minimum of one (1) inch thickness of one-fourth (1/4) inch aggregate material. DS 2-09.5.1, DS2-09.5.2, DS 2-09.5.4, & DS 2-09.6.2 Provide a detail of the proposed type of class two bicycle rack. 17. DS 2-01.3.8.R If building #3 is to be for the educational use an accessible pedestrian circulation path connecting to all buildings will be required. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\developmentplan\D10-0020dp.doc |
| 06/22/2010 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Submit the approved site/landscape plan or a revised landscape plan. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. For more specific information, refer to Development Standard 2-07.0. DS 2-01.3.X Show compliance with landscaping and screening requirements on the development plan by identifying locations, material descriptions, and dimensions (of landscape borders and planters). |
| 06/23/2010 | FERNE RODRIGUEZ | COT NON-DSD | TUCSON AIRPORT AUTHORITY | Denied | >>> "Jordan Feld" <jfeld@tucsonairport.org> 06/23/2010 7:34 AM >>> Thanks for heads up Patricia; per our previous comment letter on the special exception (which appears to have been codified with the ZE's decision transmittal dated 7/30/09 - condition #7), the developer is required to record the disclosure prior to permitting. I have not received a copy of the recordation from the developer. Please make sure our concerns are incorporated into your review. Thanks again! Jordan D. Feld, CM, AICP Director of Planning Tucson Airport Authority 7005 S. Plumer Ave. Tucson, AZ 85756 jfeld@tucsonairport.org www.tucsonairport.org (520) 573-5115 office (520) 573-8006 fax |
| 06/24/2010 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES June 24, 2010 Philip Carhuff Krebs Carhuff Architects 3149 East Prince Road, #151 Tucson, Arizona 85716 Subject: D10-0020 Academy Del Sol Development Package Dear Phil: Your submittal of June 4, 2010 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and 7 sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 7 Copies Revised Development Package (Engineering, Planning, ADA, Zoning, Landscape, TAA, PDSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 577-4599 |