Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D10-0017
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/03/2010 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/04/2010 | RONALD BROWN | ADA | REVIEW | Passed | Not a COT owned or operated property |
| 08/04/2010 | JIM EGAN | COT NON-DSD | FIRE | Denied | Fire Department approved lock box required on both gates. Additional fire hydrant required. Refer to International Fire Code (and local amendments), section 508.5.1 and 508.5.2 for requirements. Also, there was no attachments regarding hazardous material storage. Please provide. |
| 08/11/2010 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Denied | August 10, 2010 To: PAUL NZOMO CORONADO ENGINEERING & DEVELOPMENT, INC Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ____________________________________________ From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department Subject: ADDITION TO TUCSON PRECISION PRODUCTS Dev. Plan – 2nd Submittal D10-0017 The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use: Obtain a letter from the PCRWRD’s Development Liaison Unit, written within the past year, stating that treatment and conveyance system capacity for the project is available in the downstream public sewerage system and provide a copy of that letter to this office. The required form to request such a letter may be found at: http://www.pima.gov/wwm/developer.htm#permits The development plan for this project cannot be approved until a copy of this letter has been received by this office. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the third(3rd) submittal. A check for the review fee of this submittal in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. This comment letter has been reviewed and accepted for substantial conformance to Pima County Code Title 13 by: ___________________________ Chad Amateau, P.E., Civil Engineer PCRWRD, Planning Services Section, Development Liaison Unit cc: Chad Amateau, PE Kristin Greene, PE, DLU Manager DLU Project folder |
| 08/19/2010 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 08/23/2010 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Tucson Precision Products Development Plan (1st Review) D10-0017 TRANSMITTAL DATE: August 23, 2010 DUE DATE: August 31, 2010 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section conditionally approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 2. D.S. 2-05.2.4.P The parking spaces calculation is not correct. 102 plus 23 equals 125 provided. There are 124 spaces shown on the plan and parking calculation, please clarify. Zoning acknowledges that the minimum number of required vehicle parking spaces is provide, revised the calculation to reflect what is shown on the plan. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ D10-0017 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan. |
| 08/26/2010 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
| 08/27/2010 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Any required storm water detention/retention basins shall be landscaped to enhance the natural configuration of the basin. Design criteria are set forth in Development Standard 10-01.0. LUC 3.7.4.3.A. Revise the plans to include basin landscaping. The basin should include a minimum of twemty trees per acre in addition to any existing native vegetation or weeds. 2) The approved plans for the site, as well as the LUC require a 5' high masonry wall along the east property boundary. CD9-83-34Q, LUC Table 3.7.2-I Revise the plans to include the wall. 3) The plans indicate an existing brittle bush hedge within the drainage easement. Existing drainage and basin improvements will be inspected for compliance with the landscape requirememnts as part of the C of O series of inspections. 4) Add the CDRC case number to the landscape plans. |
| 09/01/2010 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES September 1, 2010 Paul Nzomo Coronado Engineering 4007 E. Paradise Falls Dr. Tucson, Arizona 85712 Subject: D10-0017 Tucson Precision Products Development Plan Dear Paul: Your submittal of May 27, 2010 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 5 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 5 Copies Revised Development Plan (Fire, Wastewater, Landscape, Zoning, PDSD) 3 Copies Revised Landscape Plan (Landscape, Zoning, PDSD) 1 Check Made out to "Pima County Treasurer" for $39.00 Should you have any questions, please call me at 837-4917. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 722-5394 |
| 09/01/2010 | PGEHLEN1 | ENV SVCS | REVIEW | Passed |