Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D09-0039
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/15/2010 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/19/2010 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Taco Bell Development Package (3rd Review) D09-0039 TRANSMITTAL DATE: April 19, 2010 DUE DATE: April 29, 2010 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section conditionally approves the development package for this project, subject to approval of final plat S10-014. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ D09-0039 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package. |
| 04/23/2010 | JASON GREEN | ENGINEERING | REVIEW | Approv-Cond | To Dave Roberts for additional review of handicap access and sidewalk design to ensure construction feasibility. 4/21/10. |
| 04/23/2010 | JASON GREEN | ENGINEERING | REVIEW | Approv-Cond | DATE: April 23, 2010 SUBJECT: Taco Bell Development Plan Package- 3rd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 1720 W Speedway Blvd, T14S R13E Sec03, Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: D09-0039 SUMMARY: Engineering Division of Planning Development Services Department has received the revised development plan package, Hydrologic/Hydraulic Report (Stanley Engineering & Drainage, Inc., 04DEC09 revised 16FEB10) and Stormwater Pollution Prevention Plan (Stanley Engineering & Drainage, Inc., 03DEC09 revised 16FEB10). Engineering Division recommends approval of the development plan package at this time conditioned upon the following item: " Approval of Activity S10-014, Final Plat reconfiguration. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning and Development Services |
| 04/26/2010 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES April 26, 2010 Al Cappello/Michelle Sawko Looker & Cappello Architects, Inc. 2070 E. Southern Avenue Tempe, Arizona 85282 Subject: D09-0039 Taco Bell @ Albertsons El Rio Plaza Development Package Dear Al and Michelle: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Zoning and Engineering, please submit the following documents for sign-off. 1 Rolled blue line COMPLETE SET of the Development Package, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. 1 Rolled blue line set of the Development Package. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional black line copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your plans to the CDRC office for sign-off approval. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4917. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/ Via fax: (480) 968-6571 |