Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D09-0027
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/17/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/01/2009 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Denied | November 25, 2009 To: ANTHONY HERRERA EPS GROUP, INC Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ___________________________ From: Tom Porter, Sr. CEA (520-740-6719), representing the Pima County Departments of Regional Wastewater Reclamation Department and Environment Quality Subject: McDONALD'S Dev. Plan –2nd Submittal D09-027 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Sheet 2: Show the existing BCS(w/pipe size) on plan serving the proposed building. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the third(3rd) submittal. A check for the review fee of this submittal in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above-mentioned comments, please contact me. |
| 12/01/2009 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 2ND FL TUCSON, AZ 85701-1207 AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: D09-0027 MCDONALD’S/REVISED DEVELOPMENT PLAN DATE: 12/01/09 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 12/09/2009 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
| 12/09/2009 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Denied | We have reviewed the Resubmitted Development Plans for the McDonald's Restaurant and the following comments are provided: 1. ADOT does not approve the new curb returns at the existing two driveways as shown on the plans. In order to provide curb returns at this location, one driveway shall be closed. Therefore, ADOT will accept curb returns at the north driveway if the south driveway is removed. The developer may relocate the north driveway to a new location. 2. Do the proposed geometric changes in ADOT right-of-way alter the existing drainage? If they do not, please state so. Also, the site shall not be graded to drain into ADOT right-of-way. 3. All work in ADOT right-of-way shall be to ADOT standards and specifications. Please, revise the KEYNOTES on Sheet 2 of 4 accordingly. 4. The proposed 6 ft. wide concrete sidewalk in ADOT right-of-way shall be constructed in conformance with ADOT Standard Drawing C-05.20. 5. Within ADOT right-of-way, we require 7" vertical curb and gutter, Type D, per ADOT Standard Drawing C-05.10. 6. Provide a Detail showing the ADA compliant sidewalk ramps at the proposed curb returns (north driveway). Provide modified sidewalk ramps per ADOT Standard Drawing C-05.30, Type B. 7. Resubmittal of the Development Plan is required. 8. Off-site Improvement Plans shall be provided to ADOT for our review, comment and approval. Thank you for the opportunity to comment on the Development Plan. Maria Deal Southern Regional Traffic Engineering ADOT 1221 S. 2nd Ave. Tucson, AZ 85713 Phone #: 520-388-4235 ________________________________ Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments. 2009 |
| 12/16/2009 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: D09-0027 McDonalds 4495 N. Oracle Rd. Development Plan TRANSMITTAL: 12/16/2009 DUE DATE: 12/17/09 COMMENTS: 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 07/13/10. 2. This comment has not been addressed completely. DS 2-05.2.4.D.3 The PAAL and landscape border along the east side of the property is partially located within the future right of way. A future development plan will be required to be provided showing how the site will still meet the code requirements once the widening occurs. See LUC Sec. 2.8.3.5.F. A copy of the required MS&R covenant can be obtained here at DSD. Recording docket and information for the covenant is required to be placed on the future site plan. 3. DS 2-05.2.4.K Per DS 2-08.3.1 A pedestrian circulation path is required to connect to the trash enclosure. FYI: The pedestrian circulation path to the trash enclosure cannot cross through the stacking spaces for the drive through per DS 3-05.2.1.C.2.a. 4. DS 2-05.2.4.W The indicated existing pole sign is overhanging the PAAL. Clearly indicate the required 15' clearance from the lowest portion of the sign to the asphalt. Provide a dimensioned detail of the existing sign clearly indicating clearance. It appears that the pole sign will be require to be relocated on the future site plan. As indicated on the plan it is overhanging into the future right of way. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\developmentplan\D09-0027-2dp.doc |
| 12/16/2009 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1. The street landscape border at Oracle is required to be located based on the MS&R right-of-way line. Landscape borders proposed in right-of-way or MS&R areas must be approved by the City Engineer or designee and comply with the City Engineer's requirements on construction, irrigation, location, and plant type. Provide verification, in writing, of any approvals obtained. Contact Gary Wittwer, DOT Landscape Architect for specific requirements. 2. Revise the plans as necessary to comply with the requirements of the MS&R Zone. LUC 2.8.3.5 No portion of the MS&R right-of-way area that is publicly owned will be used toward complying with Land Use Code (LUC) requirements, unless specifically stipulated per LUC 2.8.3.5.A 3. A 30" continuous screen along the development side of the street landscape border must be provided per LUC Table 3.7.2-I. Label the type/materials (i.e. vegetative or masonry), height and location of screening on the landscape plan. Screening elements must located per LUC 3.7.3.2.C. |
| 12/17/2009 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Denied | DATE: December 17, 2009 TO: Patricia Gehlen; CDRC Manager FOR: Anthony Herrera, PE, EPS Group Engineering SUBJECT: Development Plan Engineering Review Resubmittal PROJECT: McDonald's Restaurant renovation Development Plan LOCATION: 4495 N Oracle Rd, Ward 3 FEMA PANEL: 1636K X-unshaded REVIEWER: Elizabeth Leibold, PE ACTIVITY NUMBER: D09-0027 SUMMARY: The revised Development Plan package including development plan, drainage report, easement documentation, landscape documents, and response letter was submitted and reviewed. Planning & Development Services Department Engineering Division does not recommend approval of the Development Plan at this time. DEVELOPMENT PLAN COMMENTS: 1) DS Sec.2-05.2.3.B, 2-05.2.4.G: Provide authorization for south offsite improvements. Show where within easement documentation that the easement provides for construction / improvements. This comment must be addressed prior to Engineering Development Plan approval or conditional approval. 2) For the proposed restaurant parking area, assure that scuppers are labeled for the locations where the roof drainage exits onto the adjacent sidewalk. 3) DS Sec.3-01.5.3: Assure that the dimensions for both existing and proposed SVT's are correctly labeled. Revise sight visibility triangle locations on Development Plan sheet 2 using the SVT table per this section, using 12-ft setback for sidewalk area. Resubmittal is required. Submit response letter, copies of the cross access easement documentation, authorization to do offsite improvements, revised landscape sheet / revised Development Plan and response letter. The next submittal should address all the above items. If you have questions or would like to set up a meeting, call me at 837-4934. Elizabeth Leibold, PE Civil Engineer Engineering Division Planning & Development Services Department |
| 12/21/2009 | ANDY VERA | ENV SVCS | REVIEW | Denied | 1. Gate opening for double wide enclosure will requuire a minimum 22 ft. 2. The minimum clear container service area must be 10 ft x 10 ft between the side and rear bollards and the front gates for each, or 20 ft x 10 ft as shown. DS 6-01.4.1.B. 3. Each container area will require a minimum of three rear bollards with the outside bollards spaced 2 ft from side wall and the proceeding two bollards spaced 4 ft apart to demonstrate adequate wall protection. Side wall protection as shown is good. DS 6-01.4.2.C.2 4. Will require a minimum 14 ft x 40 ft clear approach in front of each container area. DS 6-01..4.1.C. Please provide corrections on resubmittal. If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov |
| 12/24/2009 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 12/28/2009 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES December 28, 2009 Anthony Herrera EPS Group, Inc. 17 West Wetmore, Suite 302 Tucson, Arizona 85705 Subject: D09-0027 McDonalds Development Plan Dear Anthony: Your submittal of July 14, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 7 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 7 Copies Revised Development Plan (Wastewater, AZ DOT, Landscape, Zoning, Engineering, ESD, PDSD) 4 Copies Revised Landscape Plan (Landscape, Zoning, Engineering, PDSD) 2 Copies Cross Access Parking Documentation (Engineering, PDSD) Should you have any questions, please call me at 837-4919. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 408-1403 |