Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: D09-0014
Parcel: 136100930

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D09-0014
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/12/2010 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/19/2010 FERNE RODRIGUEZ COT NON-DSD REAL ESTATE Approved >>> Jim Stoyanoff 03/19/2010 10:13 AM >>>
No comment, zoning condition #7 fulfilled.
03/26/2010 RONALD BROWN ZONING HC REVIEW Denied SHEET C3.0
1. The dectetable warnings are located in the wrong place on the sidewalk ramps (2 places) in the middle of the accessible route leading to Houghton Road. These ramps lead down to a marked flush area of the parking lot for people with carts to access the accessible aisle. The detectable warnings must be located just on the edge of the accessible asile prior to entering the marked asphaltic paving asile with the required 2' deep oriented to the direction of travel. We would prefer you not have these elements at all as they are a false warning for vision impared persons that think they are in an marked crossing leading to a safe area when in fact, they are being dumped into the traffic aisle with no further direction provided.
2. Insure that the two marked crossings leading to the existing CVS Pharmacy have the proper ramps and detectable warnings on at the CVS side to comply with providing a complete marked crossing.
3. Insure that the marked crossing to the main store entrance is identified with a different striping than that of the rest of the stripped hazardous area show. Maybe paint the stripes at a diagonal.
SHEET C6.1
4. The detectable warning strip shown on the sidewalk ramp leading down to the area between the accessible parking spaces is not required. this is a safe zone with no traffic.
5. The accessible signage shown on sheet C6.3 is in conflict with the accessible signage shown on sheet C6.2. Please coordinate.
END OF REVIEW
04/01/2010 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved PLANNING & DEVELOPMENT SERVICES COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D09-0014 Walmart Houghton-Golf Links 4/1/10

( ) Tentative Plat
(X) Development Plan
(X) Landscape Plan
(X) Other - Dimensioned elevations/ color renderings

CROSS REFERENCE: C9-89-13

NEIGHBORHOOD PLAN: South Pantano

GATEWAY/SCENIC ROUTE: Scenic

COMMENTS DUE BY: 4/12/10

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:
(XXXX) No Resubmittal Required - Complies With Planning Comments Submitted on: 12/24/09
04/06/2010 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Approved March 31, 2010

To: DANIEL SKEEHAN
KIMLEY-HORN AND ASSOCIATES, INC.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

____________________________________________
From: Tom Porter, Sr. CEA (520-740-6719), representing the Pima County Departments of Regional Wastewater Reclamation Department and Environment Quality

Subject: WAL-MART SUPERCENTER (STORE #5799-00)
Dev. Plan – 3rd Submittal
D09-014


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The Pima County Department of Environmental Quality and Regional Wastewater Reclamation Department hereby approve the above referenced submittal of the development plan as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.
04/08/2010 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: D09-0014
Walmart - Store No. 5799-00 (Retail - General Merchandise Use)
Development Plan - (Houghton / Golf Links)

TRANSMITTAL DATE: April 8, 2010

DUE DATE: April 12, 2010

COMMENTS: Conditional Approval, see comments below.

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is May 10, 2010.

2. Please revise the note that refers to the loading size as follows. Depressed Loading Docks 6 @ 12' x 130'

3. This development plan is conditionally approved pending approval of the Scenic Corridor application. See comments in Permits Plus related to the Scenic Corridor Review. Revise drawing as required.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\developmentplan\D090014dpb.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan
04/09/2010 LOREN MAKUS ENGINEERING REVIEW Approved April 9, 2010
D09-0014
Development Plan - Third Review
Reviewed by Loren Makus, EIT

The engineering division recommends approval of the development plan for this project.
A complete grading permit submittal will be required for this project. The grading permit must include a complete Stormwater Pollution Prevention plan meeting the requirements of the ADEQ construction permit.
04/09/2010 JOE LINVILLE LANDSCAPE REVIEW Approved
04/16/2010 JOSE ORTIZ COT NON-DSD TRAFFIC Approv-Cond A meeting with TEP is required to establish if an easement can be secured for the required right turn lane for the southern access drive off of Houghton Road. The right turn lane will not impact the development plan and if permitted by TEP the improvements can be reflected on the PIA (Private Improvement Agreement) plan.
04/16/2010 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES


April 16, 2010

Dan Skeehan, P.E.
Kimley-Horn and Associates, Inc.
2210 E. Fort Lowell Road, # 200
Tucson, Arizona 85719

Subject: D09-0014 Wal-Mart - Houghton/Golf Links Development Plan

Dear Dan:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Zoning HC, Zoning, & Traffic, please submit the following documents for sign-off.

1 Rolled blue line COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews.

1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan.

Additional black line copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. The printing company will deliver the original rolled blue line to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html.
BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION.

Should you have any questions, please call me at 837-4917.

Sincerely,







John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (602) 678-3464