Permit Number: D09-0002
Parcel: 141012130

Review Status: Completed

Review Details: DEVELOPMENT PLAN

Permit Number - D09-0002
Review Name: DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2009 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/30/2009 DAVID MANN COT NON-DSD FIRE Denied The building must be fire sprinklered. See IFC 903.2.7.
02/05/2009 TIM ROWE PIMA COUNTY WASTEWATER Denied February 4, 2009

To: JEFF STANLEY
STANLEY ENGINEERING

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

______________________________________________
From: Tom Porter, Sr. CEA (520-740-6719), representing the Pima County Departments of Wastewater Management and Environment Quality

Subject: BALLET RINCON STUDIO
Dev. Plan - 1st Submittal
D09-002


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

Sheet 1: Add a General Note that states:

THIS PROJECT WILL HAVE ______ EXISTING AND______ PROPOSED WASTEWATER FIXTURE UNIT EQUIVALENTS PER TABLE 13.20.045(E)(1) IN PIMA COUNTY CODE 13.20.045(E).

And fill in the blanks with the appropriate values.

Sheet 1: Remove General Wastewater Note #4 and insert the following General Note:

THE ON-SITE SANITARY SEWERS WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS, AND IN ACCORDANCE WITH AN APPROVED OPERATION AND MAINTENANCE PLAN, IF REQUIRED. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

Sheet 1: If the sewer already exists then disregard the above note and revise the following:

Revise Wastewater General Note #4 to read as follows:

THE ON-SITE SEWERS ARE EXISTING AND PRIVATE. NO NEW SEWERS ARE PROPOSED.

Show the existing 4” HCS as extending to the building and eliminate Keynote #5.

Sheet 1: In the Legend add a symbol for existing sewer line and manholes verses proposed.

Sheet 1: 1 If new sewer is proposed then add a Permitting Note that states:

A PROJECT CONSTRUCTION PERMIT MUST BE SECURED FROM PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT BEFORE BEGINNING ANY WORK ON THIS PROJECT.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above-mentioned comments, please contact me.
02/09/2009 FERNE RODRIGUEZ OTHER AGENCIES PIMA ASSN OF GOVTS Approved CASE: D09-0002 BALLET RINCON STUDIO: DEVELOPMENT PLAN

COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS





Vehicle Trip Generation: Daily: 75 PM Peak: 39











Please call if you have questions or need additional information.





-------------------------------------------

KoSok Chae, Ph.D.



177 N. Church Ave., Suite 405

Tucson, AZ 85701



520-792-1093 x487 [tel]

520-620-6981 [fax]

www.PAGnet.org
02/10/2009 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: February 10, 2009
CDRC/Zoning Manager

SUBJECT: Ballet Rincon Studio, 10544 E. Seven Generations Way
Development Plan D09-0002 (First Review)
T15S, R15E, Section 01

RESUBMITTAL REQUIRED: Development Plan.

The Development Plan (DP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Development Plan:

1. Please include a response letter to the comments along with the corrected copies of the DP.
2. Please provide property description per D.S. 2-02.2.1.3.
3. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
4. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
5. Complete Development plan number (D09-0002) on all sheets per D.S. 2-02.2.1.29.
6. It appears that the 6' PUE extends 5' North beyond the P.T. than as shown. Revise drawing as required.


If you have any questions, I can be reached at 837-4932 or Paul.Machado@ci.tucsonaz.govs
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/10544 E. Seven Generations Way DP
02/12/2009 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
02/12/2009 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. Add the CDRC Development Plan case number (D09-0002) and any other related case numbers to the lower right hand corner of all sheets of the plan.

2. Revise plan to show the existing street landscape border located within the right-of-way in Seven Generations Way along with the existing wedge curb and radius to reflect the actual streetscape condition.

3. The Native Plant Preservation Application for Exception is approved as submitted.
02/18/2009 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#207878 February 17, 2009


Stanley Engineering & Drainage
Attn: Jeffrey Stanley
PO Box 1888
Tucson, AZ 85702

To Mr Stanley :

SUBJECT: Ballet Rincon Studio
D09-0002


Tucson Electric Power Company has reviewed and approved the development plan submitted February 10, 2009 It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. All relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Rich Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-918-8726

Please call the area Designer Nancy DiMaria at (520) 918-8267, should you have any questions.


Sincerely,



Henrietta Noriega
Office Specialist
Design/Build
hn
Enclosures
cc: City of Tucson, (Email only)
N. DiMaria Tucson Electric Power
02/23/2009 JOSE ORTIZ COT NON-DSD TRAFFIC Denied February 19, 2009
ACTIVITY NUMBER: D09-0002
PROJECT NAME: Ballet Rincon
PROJECT ADDRESS: 10544 E Seven Generations Wy
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the Development Plan; therefore a revised Development Plan is required for re-submittal.

The following items must be revised or added to the development plan.

1. Include a response letter with the next submittal that states how all comments have been addressed.

2. Illustrate the location of the existing pavement and any proposed modifications to the existing pavemen.

3. Show and label the sight visibility table (SVT) (DS 2-03.2.4.M). The proposed structure cannot conflict with the SVT


If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov
02/24/2009 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
D09-002
10544 East Seven Generations Way
Dance Studio & Residence
Civano I Lot 99 (141-01-2130)


TRANSMITTAL: February 24, 2009


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1) This review is subject to Development Standards No.2-05, the Land Use Code and PAD 12, Civano I, Neighborhood Center District.

2) A maximum of one (1) year is allowed from the date of application to obtain approval of a development plan (LUC Section 5.3.8.2). The one-year expiration date for this development plan is January 27, 2010.

3) The primary use(s) must be identified on the plan. The dance studio would be an instructional school and the office would be part of that use if it is for the dance studio (LUC Section 6.3.4.6.C). You have three uses listed on the development plan; office, dance studio and personal service. This would be applicable for three different businesses. Please clarify the intended use or uses on the plan. The correct use group for an instruction school is the "Civic Use Group" (DS 2-05.2.2.B.3). (See Civano I, PAD 12; F-3.3.1, Neighborhood Center District.) The instructional school use matches the parking calculations provided on this plan. Please revise the uses and the use group.

4) Provide the corner sections on the location map (DS 2-05.2.1.D.3).

5) Provide a reduced scale map of the entire Civano PAD on the first sheet (DS 2-05.2.1.F).

6) Identify the number of residential units (DS 2-05.2.2.B.4). It this instance, identify it as a single-family residence (SFR).

7) The "C9-91-14" is a correct rezoning case number, so do not take it out of the list (DS 2-05.2.2.B.7).

8) Provide the name of the public alley ROW "Firebush Lane" on the development plan. Also delineate the curb and sidewalk information with dimensions on the plan (DS 2-05.2.3.C).

9) Show the on-site pedestrian circulation (DS 2-05.2.4.K). See LUC Section 3.2.8 and DS 2-08. Pedestrian circulation must provide access to all public access areas, such as bicycle parking, trash facilities and other common uses, and all public streets that abut the site (2-08.3.1). The pedestrian circulation path must be an accessible route (DS 2-08.3.1)

10) Provide the dimensions for the building and the location of the building, relative to the property lines, along with the building's heights, on the plan (DS 2-04.2.4.N).

11) Clearly identify the residential parking, the garage and driveway on the development plan (DS 2-05.2.4.P).

12) "Show, on the drawing, off-street bicycle paring locations, including materials for lighting and paving, type of security, dimension, specific type of rack and number of bicycles it supports, and the location and type of directional signage. When adjacent to pedestrian paths, indicate the width of clearance available for the pedestrian area. For specifics, refer to Development Standard 2-09.0" (DS 2-05.4.Q).

13) Provide a fully dimensioned bicycle parking layout plan on the development plan (DS 2-05.2.4.Q). This is typically done with a detail. See Bicycle Parking and Security Measures (DS 2-09.5. all).

14) It appears that the pedestrian access and the bicycle parking may be overlapping. These two things must be keep separate (DS 2-09.3.2). "Bicycle parking must not obstruct the approved pedestrian access" DS 2-09.4.1).

15) Class 2 bicycle parking must be within fifty (50) feet of the main building entrance(s) along the front side of the building (DS 2-09.4.1 & Figure 8).

16) Class 2 bicycle parking must be clearly visible for the main entrance, adjacent sidewalks and drives (DS 2-09.4.4).

17) Provide dimensioned floor plans, elevations and sections of the proposed structure. Clearly delineate between the residential and commercial space (DS2-05.2.2.B.3).

18) "Indicate location and type of postal service"… (DS2-05.2.4.V).

19) "Indicate the locations and types of proposes signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational (sic) requirements can be met" (DS2-05.2.4.W).

20) Please be aware that further comments may be forthcoming relative to additional information provided with subsequent submittals.
02/24/2009 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING AND DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D09-0002 Ballet Rincon Studio 2/24/09

() Tentative Plat
(X) Development Plan
() Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
() Other

CROSS REFERENCE: S97-035, C9-91-14

NEIGHBORHOOD PLAN: Civano PAD

GATEWAY/SCENIC ROUTE: N/A

COMMENTS DUE BY: February 27, 2009

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
(ü) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
(ü) Resubmittal Required:
() Tentative Plat
(X) Development Plan
() Landscape Plan
( X ) Update Neighborhood Center District Parking Inventory

REVIEWER: JBeall 791-4505 DATE: February 24, 2009



Comments

1. Please clarify the primary land uses of the site, i.e. as a dance studio would come under Civic Use Group.

2. Please show that the residential use requires 2 parking spaces, but with 50% reduction only 1 space needed.

3. Please provide name of the public alleyway on site plan.

4. Please correct the Loading Zone calculation information to read "greater than 2500 SF ".

5. Provide dimensions and elevations of the building and relationship to property lines on the site plan. Where is the main entrance of the house/dance studio? Office?

6. Please provide a bicycle parking layout as all required bicycle parking should be conveniently located to the main building entrance, and with pedestrian access to the main entrance.
02/25/2009 RONALD BROWN ZONING HC SITE REVIEW Denied 1. These plans do not contain sufficient detail for a complete and proper Accessible Review.
2. Please complete the site details as required by Zoning and resubmit.
02/25/2009 FERNE RODRIGUEZ COT NON-DSD REAL ESTATE Approved No comment
02/25/2009 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved ADOT has NO COMMENT on this project.

--------------------------------------------------------


Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
03/02/2009 ED ABRIGO PIMA COUNTY ASSESSOR Passed
03/02/2009 ROBERT YOUNG PIMA COUNTY PIMA CTY - DEV REVIEW Passed
03/03/2009 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: March 02, 2009

TO: DSD_CDRC@ tucsonaz.gov

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov


SUBJECT: D09-0002 Ballet Rincon Studio: Development Plan(1/29/09)


Staff has no comments.
03/04/2009 ANDY VERA ENV SVCS REVIEW Approv-Cond 1. Identify onsite container storage area that is screened from public view.

Adequate street frontage access for curbside refuse/recycle collection service for this facility type.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
03/23/2009 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

JENNIFER STEPHENS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL
SUBJECT: D09-0002 BALLET RINCON STUDIO/DEVELOPMENT PLAN
DATE: 3/09/09



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Label project number on each sheet.
Correct legal description in Title Block to read “located in Civano 1, Lot 99 (Bk 50, Pg 56) of Pima County Maps & Plats and being a portion of section…G& SRM, Pima County, Tucson, Arizona.”
Label section corners on Location Map.
03/24/2009 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 24, 2009

Jeffrey A. Stanley
Stanley Engineering & Drainage, Inc.
P.O. Box 1888
Tucson, Arizona 85702

Subject: D09-0002 Ballet Rincon Studio Development Plan

Dear Jeff:

Your submittal of January 29, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and 11 sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

11 Copies Revised Development Plan (Fire, Wastewater, Engineering, Landscape, Traffic, DUPD, Zoning, ADA, ESD, Addressing, DSD)

5 Copies Revised Landscape Plan (Engineering, Landscape, DUPD, Zoning, DSD)

3 Copies Dimensioned Building Elevations & Floor plans (DUPD, Zoning, DSD)


Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager



All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 792-0318
dp-resubmittal