Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D08-0053
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/21/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 01/22/2009 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 01/29/2009 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | 1) Add the CDRC case number and any related case numbers to the landscape and native plant preservation plans. DS 2-07.2.1.B The Development Plan includes C9-08-08 and D99-0052 as reference cases. Include these on the landscape plan if they are indeed related. 2) OCSD approval of the water harvesting plan is required. |
| 02/02/2009 | STEVE SHIELDS | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Towne Place Suites Development Plan (2nd Review) D08-0053 TRANSMITTAL DATE: February 2, 2009 DUE DATE: February 19, 2009 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/Developmentplan/ D08-0053-2nd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: |
| 02/05/2009 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Approved | February 03, 2009 To: THOMAS SAYLER-BROWN SBBL ARCHITECTURE & PLANNING Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Chandubhai C. Patel, P.E., Civil Eng. Manager Development Review Division ( Wastewater) Subject: TOWNEPLACE SUITES HOTEL Dev. Plan – 2nd Submittal D08-053 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (RWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The PDEQ and the PCRWRD hereby approve the above referenced submittal of the Development Plan as received by us on January 21, 2008. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in any activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Copy: Project File |
| 02/06/2009 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: February 6, 2009 SUBJECT: Towne Place Suites Development Plan- 2nd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 384 S Williams Blvd, T145S R14E Sec14 Ward 6 REVIEWERS: Jason Green, CFM ACTIVITY: D08-0053 SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed Development Plan and Drainage Report (Greg Carlson Engineering, Inc., 20NOV08 revised 16JAN09). Engineering Division recommends approval of the Development Plan at this time. DEVELOPMENT PLAN: 1) Complied. 2) Complied. 3) Complied. 4) Complied. 5) Complied. 6) Complied. 7) Complied. 8) Complied. 9) Complied. 10) Complied. 11) Complied. 12) Complied. 13) Complied. 14) Complied. 15) Complied. 16) Complied. 17) Complied. 18) Complied. 19) Complied. 20) Complied. 21) Complied. 22) Complied. 23) Complied. 24) Complied. 25) Complied. 26) Complied. 27) Complied. 28) Complied DRAINAGE STATEMENT: 29) Complied. 30) Complied. 31) Complied. 32) Complied. 33) Complied. GRADING PLAN: 34) Restated: DS Sec.11-01.2.1: A grading permit is required for this project. A grading plan and a grading permit application will be required after Development Plan approval and prior to any construction activity. 35) Restated: Please ensure that any future grading plan will be consistent with the Development Plan, Drainage Report, and Geotechnical Report. Grading standards may be accessed at: http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf 36) Restated: Arizona Pollutant Discharge Elimination System (AZPDES) is applicable to this project. Stormwater Pollution Prevention Plans (SWPPP) and text addressing stormwater controls for all areas affected by construction activities related to this development will be required. For further information, visit www.adeq.state.az.us/environ/water/permits/stormwater.html. GENERAL COMMENTS: Please provide the Development Plan Mylar for review through the CDRC office. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 02/09/2009 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D08-0053 Towne Place Suites 02/06/09 ( ) Tentative Plat (X) Development Plan (X) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other CROSS REFERENCE: Williams Addition PAD, C9-08-08 NEIGHBORHOOD PLAN: Williams Addition PAD GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: 2/19/09 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached (X) No Additional Comments - Complies With Planning Comments Submitted on:12/30/08 REVIEWER: MSP 791-4505 DATE: 02/06/09 |
| 02/10/2009 | INPL | COT NON-DSD | OCSD | Approved | |
| 02/12/2009 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: D08-0053 TOWNE PLACE SUITES/REVISED DEVELOPMENT PLAN DATE: 2/11/09 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 02/13/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES February 13, 2009 Thomas or Carolyn SBBL Architecture & Planning 1001 North Alvernon Way, #105 Tucson, Arizona 85711 Subject: D08-0053 Towne Place Suites Development Plan Dear Thomas: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line comments, please submit the following documents for sign-off. 1 Rolled blueline COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. AND 1 Rolled blueline set of the Development Plan. AND 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. The extra rolled blueline set that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the rolled bluelines to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 620-0535 dpapproved |