Permit Review Detail
Review Status: Completed
Review Details: REVISION - DEV PLAN
Permit Number - D08-0050
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/17/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 11/17/2009 | RONALD BROWN | ADA | REVIEW | Passed | Not a COT owned/operated property |
| 11/24/2009 | RONALD BROWN | ZONING HC | REVIEW | Denied | 1. The Southern end of the most Easterly marked crossing must have a detectable warning at the North end of the accessible parking aisle. 2. Please provide a large scale detail of all the different types of ramps showing dimensions, slopes, marked crossings as connected, detectable warnings, flared sides or turn back curbs as required. Insure compliance with ICC (ANSI) 117.1 Sections 405 and 406 as applicable. 3. Please provide a detectable warning strip on the most Westerly end of the marked crossing connecting building 1 to building 2. 4. The accessible parking shown at building 2 needs a ramp. 5. On the site plan, please identify the location of the required "Van Accessible" parking spaces. 6. Clarify on drawings the accessible route and that all running slopes are not more than 5% and all cross slopes are not more than 2%. 7. Clarify that all accessible parking spaces have slopes in all direction of no more than 2%. At the most Southerly accessible parking space in front of building 2, a slope is indicated as 2.97%. This doeas not meet code requirement of 2% max slope. END OF REVIEW |
| 12/02/2009 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: D08-0050 - R Radiology LTD. Lot 22 Midvale Development Plan - Revision TRANSMITTAL: 12/02/2009 DUE DATE: 12/04/09 COMMENTS: 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 11/17/10. 2. DS 2-05.2.2.B.6 A DSMR has been applied for this site. If the DSMR is approved for this project, please add the DSMR case number, what the DSMR is for, date of approval and any conditions of approval on the development plan (DP). 3. A handicap ramp is missing at the handicap parking access aisle located near the southeast corner of building #2 If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\developmentplan\D08-0050-Rdp.doc |
| 12/03/2009 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 12/04/2009 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES December 8, 2009 Joe Zeman Leadstar, LLC 6303 E Tanque Verde Rd. # 101 Tucson, Arizona 85715 Subject: D08-0050 Radiology LTD Development Plan Dear Joe: Your submittal of November 17, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 3 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Development Plan (HC Site, Zoning, PDSD) Should you have any questions, please call me at 837-4919. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 547-0195 |
| 12/04/2009 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved |