Permit Number: D08-0045
Parcel: 14041075A

Review Status: Completed

Review Details: DEVELOPMENT PLAN

Permit Number - D08-0045
Review Name: DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/25/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/30/2008 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
10/02/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. Revise street landscape border calculation for the border along Bonney Avenue to be correct. The required and provided coverage calculation is incorrect. Also, the number of canopy trees required and provided in this street landscape border is incorrect. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border or fraction therof per LUC 3.7.2.4. With 101 linear feet of street landscape border along Bonney Avenue, a total of 4 canopy trees are required. Revise calculation. However, the drawing need not be revised as the additional parking lot tree adjacent to this street landscape border may be counted towards meeting the 4th canopy tree requirement so no additional trees will be required.

2. In the landscape legend indicate the names (both proper and common) of the existing shrubs to remain in place. Some
types of shrubs are not suitable within the sight visibility triangle per DS 2-06.3.8.G

3. The Native Plant Preservation Application for Exception is approved.
10/02/2008 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved ADOT has NO COMMENT on this project.

--------------------------------------------------------


Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
10/02/2008 PETER MCLAUGHLIN ZONING REVIEW Denied 1. The minimum required text size is 12 point (0.12") per DS 2-05.2.1.C. Revise all lettering within the location maps on development plan sheets 1, 2 and 3 which does not meet this minimum criteria.

2. Place the CDRC development plan case number (D08-0045) in the lower right hand corner of all sheets of the development plan and landscape plan per DS 2-05.2.2.B.2.
10/02/2008 FERNE RODRIGUEZ OTHER AGENCIES PIMA ASSN OF GOVTS Approved CASE: D08-0045 UNIVERSAL AVIONICS PARKING LOT: DEVELOPMENT PLAN

COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS





Vehicle Trip Generation: Daily: NOT AVAILABLE











Please call if you have questions or need additional information.





-------------------------------------------

KoSok Chae, Ph.D.



177 N. Church Ave., Suite 405

Tucson, AZ 85701



520-792-1093 x487 [tel]

520-620-6981 [fax]

www.PAGnet.org
10/03/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
10/06/2008 DAVID MANN COT NON-DSD FIRE Approved
10/08/2008 TIM ROWE PIMA COUNTY WASTEWATER Denied October 7, 2008

To: CHUCK SCHUITEMAN
GROMATZKY DUPREE & ASSOCIATES SOUTHWEST, LLC

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

___________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: UNIVERSAL AVIONICS
Dev. Plan - 1st Submittal
D08-045


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

Are no new sewers proposed? If so then include the following General Note:

THE ON-SITE SEWERS ARE EXISTING AND PRIVATE. NO NEW SEWERS ARE PROPOSED.

Show the existing public and private sewer lines. Include the construction plan #/pipe size and IMS #’s for the existing public sewer. Also include the rim and invert elevations for the existing public manholes.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above-mentioned comments, please contact me.
10/10/2008 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: October 10, 2008

TO: DSD_CDRC@ tucsonaz.gov

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov


SUBJECT: D08-0045 Universal Avionics: Development Plan(9-25-08)



Staff has no comments.
10/20/2008 LOREN MAKUS ENGINEERING REVIEW Denied October 20, 2008
D08-0045
Universal Avionics Parking Lot

The Engineering Division cannot approve this development plan at this
Provide details for sediment trapping for incoming streams. Provide settling chambers or some other method for preventing accumulation of sediment which could adversely impact the long-term effectiveness of the system.

Clearly identify and describe maintenance access to the chambers and provide detailed descriptions for cleaning and maintenance procedures for the chambers.

Loren Makus, EIT
Loren.makus@tucsonaz.gov
10/22/2008 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D08-0045 Universal Avionics Parking Lot 10/22/08

( ) Tentative Plat
(XXXX) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other -

CROSS REFERENCE:

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 10/23/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
(XXXX) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies with Plan Policies
( ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: drcorral 791-4505 DATE: 10/03/08
10/22/2008 ANDY VERA ENV SVCS REVIEW Approved Parking lot expansion will have no effect to the existing solid waste disposal requirements/conditions.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
10/22/2008 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
10/23/2008 ED ABRIGO PIMA COUNTY ASSESSOR Passed
10/23/2008 ROBERT YOUNG PIMA COUNTY PIMA CTY - DEV REVIEW Passed
10/28/2008 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR# 204003 October 22, 2008



Gromatzky Dupree & Assoc. SW LLC
Attn: Chuck Schuiteman, AIA
250 S Craycroft Rd #200
Tucson, Arizona 85711

Dear Chuck Schuiteman:

SUBJECT: Universal Avionics Parking Lot
D08-0045

Tucson Electric Power Company (TEP) has reviewed the plan submitted October 7, 2008. TEP is unable to approve the plan at this time. There are existing electrical facilities within the boundaries of this project. In order for TEP to approve the plan the facilities and easements must be depicted on the plans.

Enclosed is a copy of a TEP facility map showing the approximate location of the existing facilities. The (3) phase transformer UVA-1 is shown incorrectly on the map, the location is different than shown on the site plan. All costs associated with the relocation of the facilities in conflict will be billable to the developer.

Please resubmit two revised bluelines to City of Tucson Development Services Department for TEP’s review. You may contact the area Designer, Warren McElyea at 918-8268 should you have any technical questions.

Sincerely,



Henrietta Noriega
Office Specialist

hn
Enclosure
cc: City of Tucson (by e-mail)
W. McElyea, Tucson Electric Power
10/28/2008 FERNE RODRIGUEZ COT NON-DSD REAL ESTATE Approved no comment
10/28/2008 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

JENNIFER STEPHENS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL
SUBJECT: D08-0045 UNIVERSAL AVIONICS PARKING LOT/DEVELOPMENT PLAN
DATE: 10/22/08



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Label project number on all sheets.
Delete address from Title Block on all sheets.
Correct legal description for project in Title Block on all sheets.
Delete Location Map from sheet 2 and 3.
Add North Arrow to Sheet 2 (adjacent to scale information).
Spell out suffixes for all streets on all corresponding sheets.
Correct surrounding lot (south of project) from Lot 38 to Lot 37 and add Lot 38 in correct location on all corresponding sheets.
Add surrounding Lot 64 in correct location on all corresponding sheets.
10/31/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 31, 2008

Chuck Schuiteman, AIA
Gromatzky Dupree & Associates Southwest LLC
250 South Craycroft Road, Suite 200
Tucson, Arizona 85711

Subject: D08-0045 Universal Avionics Development Plan

Dear Chuck:

Your submittal of September 25, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and 7 sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

7 Copies Revised Development Plan (Landscape, Zoning, Wastewater, Engineering, Addressing, TEP, DSD)

4 Copies Revised Landscape Plan (Landscape, Zoning, Engineering, DSD)






Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 881-4390
dp-resubmittal