Permit Number: D08-0039
Parcel: 141113790

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D08-0039
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/22/2011 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/23/2011 MARTIN BROWN COT NON-DSD FIRE Approved
03/31/2011 STEVE SHIELDS ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Planning Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: 8174 Camino de Cafe
D08-0039
Development Plan (Revision)

TRANSMITTAL DATE: March 31, 2011

DUE DATE: April 5, 2011

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\cdrc\developmentplan\D08-0039dp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
04/01/2011 JOE LINVILLE LANDSCAPE REVIEW Approved
04/04/2011 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Engineering and Floodplain Review, 04/04/2011,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Lot 16 Brown/Rita Ranch
D08-0039, T15S, R15E, SECTION 27

RECEIVED: Revised Development Plan, Landscape Plan and Drainage Report on March 22, 2011

The subject submittal has been reviewed. The Drainage Report is acceptable for Development Plan purposes and it is hereby approved. Additional drainage information may be required during site grading. The Development Plan is recommended for approval pertaining to Engineering and Floodplain Review.
04/05/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES


April 5, 2011

D. Floyd Thumm
Physical Resource Engineering, Inc.
P.O. Box 36985
Tucson, Arizona 85740

Subject: D08-0039 LOT 16 BROWN RITA RANCH Development Plan

Dear Floyd:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Zoning HC*, please submit the following documents for sign-off.

1 Rolled blue line COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews.

1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan.

* Zoning HC reviewer Ron Brown graciously has changed his review from a "Denial" to "Conditional Approved" on the condition that prior to bringing in the rolled set for stamping, that you meet with him over the counter to go over the comments. He can be reached at 837-4908.

Additional black line copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. The printing company will deliver the original rolled blue line to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

Plans will not be signed and released until the CDRC office has been notified by PC Addressing that all fees for this plan have been paid. The CDRC office will need this confirmation in writing

PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html.
BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION.

Should you have any questions, please call me at 837-4893.
Sincerely,


John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 690-1769
04/05/2011 RONALD BROWN ZONING HC REVIEW Approv-Cond A CONDITIONAL APPROVAL HAS BEEN GIVEN PROVIDE THE APPLICANT REVIEW THE COMMENTS WITH RON BROWN AND MAKE FINAL ADJUSTMENTS FOR FINAL APPROVAL.

1. OK
2. The marked crossing does not work:
a. Relocate the detectable warning to the west end of the accessible parking aisle, just prior to entering the PAAL.
CHANGE THE LOCATED AS DIRECTED
b. OK
3. Show the location of the accessible parking signage on the site plan and all enlarged details.
DETAIL 3/4 SHOWS THE SIGNAGE MOUNTED TO A POLE BUT IT IS NOTED TO BE MOUNTED TO BUILDING. PLEASE RECONCILE.
4. Revise detail 3 as per comments 1 and 2 above.
PLEASE RECONCILE DETAIL TO COMMENTS.
5. OK
6. OK
7. Additional comments may be forth coming depending on how each comment above has been addressed. Please address all comments in writing.
REFERENCE RESUBMITTAL COMMENTS IN ALL CAPS.
END OF REVIEW