Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D08-0038
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2009 | FERNE RODRIGUEZ | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#202775 December 31, 2008 Physical Resource Engineering Attn: Dennis Donovan P.O. Box 36985 Tucson, Arizona 85740 Dear Mr. Donovan : SUBJECT: Rita Ranch/ Lot 19 Brown D08-0038 Tucson Electric Power Company has reviewed and approved the development plan submitted December 15, 2008. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Ms. Mary Boice New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8732 Should you have any technical questions, please call the area Designer Warren McElyea at (520) 918-8268. Sincerely, Elizabeth Miranda Office Support Specialist Design/Build lm Enclosures cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email) W. McElyea, Tucson Electric Power |
| 01/06/2009 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approv-Cond | Laith Alshami, Engineering and Floodplain Review, 01/06/2009, TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: Lot 19, Brown/Rita Ranch D08-0039, T15S, R15E, SECTION 27 RECEIVED: Development Plan, Landscape Plan and Drainage Report on December 15, 2008 The subject submittal has been reviewed. The Drainage Report is acceptable for Development Plan purposes and it is herby approved. Additional drainage related information may be required with the grading plan submittal. The Landscape Plan is acceptable pertaining to Engineering and Floodplain Review. The Development Plan is recommended for conditional approval, pertaining to Engineering and Floodplain Review, subject to providing the following information on the Development Plan Mylar: 1. Although this parcel is part of a recorded plat, the subject Development Plan is a stand alone document that should include all required information. The Basis of Bearing and the tie between the basis of bearing and one of the subject parcel corners shall be clearly shown and called out, as required by D.S. 2-05.2.3.A. RESUBMITTAL REQUIRED: Development Plan Mylar |
| 01/12/2009 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Denied | January 07, 2009 To: Dennis Donovan, P.E. Physical Resources Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Chandubhai C. Patel, P.E., Civil Eng. Manager Development Review Division ( Wastewater) Subject: Lot 19, Brown/Rita Ranch Dev. Plan – 2nd Submittal D08-038 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Sheet 3: You are showing a proposed HCS upto the property line. This HCS should be shown connecting to the Public Sewer or an existing stubout. Identify the line between the property line and the Public Sewer and label it as existing or proposed HCS. If it is a proposed one, then use the same line type as used for the HCS from the Bldg. Sheet 3: Show the invert elevation of the HCS at its connection point with the Public Sewer. Sheet 3: Provide a Clean Out where the proposed HCS makes a turn at the property line. Sheet 3: Label the existing Public Sewer in Caminoa De Café with its Pima county plan number. Sheet 3: Show existing MHs, on the existing Public Sewer, on the u/s and d/s sides of the point of connection of the HCS with the Public Sewer, and provide the rim and invert elevations for these MHs. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. The next submittal of this project will be the third submittal. A check for the review fee of this submittal in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If you have any questions regarding the above-mentioned comments, please contact me. |
| 01/12/2009 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 01/21/2009 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: D08-0038 LOT 19 BROWN/RITA RANCH/REVISED DEVELOPMENT PLAN DATE: 1/20/09 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. 1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 01/22/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES January 22, 2009 Dennis L. Donovan PRE P.O. Box 36985 Tucson, Arizona 85740 Subject: D08-0038 Lot 19 Brown/Rita Ranch Development Plan Dear Dennis: Your submittal of September 5, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and 2 sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 2 Copies Revised Development Plan (Wastewater, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 690-1769 dp-resubmittal |
| 12/12/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/15/2008 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 12/17/2008 | STEVE SHIELDS | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: 8198 Camino de Cafe D08-0038 Development Plan (2nd Review) TRANSMITTAL DATE: December 17, 2008 DUE DATE: January 13, 2009 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\cdrc\developmentplan\D08-0038-2nd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: |
| 12/17/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved |