Review Details: DEVELOPMENT PLAN
Permit Number - D08-0037
Review Name: DEVELOPMENT PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/11/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/13/2008 | DAVID MANN | COT NON-DSD | FIRE | Approved | |
| 08/15/2008 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | ADOT has NO COMMENT on this project -------------------------------------------------------- Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments. |
| 08/18/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | SHEET 2 OF 3 1. At Keynote 3, change the dot 207 reference to 2006 IBC/ICC 117.1 scetion 405s and 406. 2. At the 90 sidewalk 90 degree turn, change the keyed note to note 3. 3. Provide a Detectable Warning strip at the bottom of the ramp on the East side of the building where the concrete walkway ends. SHEET 3 of 3 4. At detail E, provide a "Van Accessible" sign mounted to pole. 5. Detail "A": a. Dimension wideths of all concrete walkway, acceessible routes, 5'? b. All ramps shown with slopes of 1:12 with a rise more than 6" must have handrails on both sides of ramp. ICC 117.1, Section 405.8. c. The corner ramp landing at the NE corner of the building must have a minimum of 5'x5' square. |
| 08/19/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Lot 34 Brown/Rita Ranch D08-0037 Development Plan (1st Review) TRANSMITTAL DATE: August 20, 2008 DUE DATE: September 09, 2008 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is August 11, 2009. 2. Double the size of the CDRC stamp shown on the plan on all sheets. 3. D.S. 2-05.2.2.B.2 Place the development plan number D08-0037 in the lower right hand corner of the plan. 4. D.S. 2-05.2.3.B The is a sixty (60) foot gas easement that crosses the south end of this parcel, show the easement on the plan along with the recording docket and page. 5. D.S. 2-05.2.4.D.3 Provide a dimension from the proposed landscape island curbing, located on the east side of the western entrance parking area access lane (PAAL), to the proposed sidewalk along the north side of the proposed building. 6. D.S. 2-05.2.4.P Due to the handrail called out under Keynote 42 the handicapped vehicle parking space is required to be ten (10) foot wide, see D.S. 3-05.2.1.3 When the side(s) of a parking space abuts any vertical barrier over six (6) inches in height, other than a vertical support for a carport, the required width for the space is ten (10) feet to provide extra width to allow passengers to enter and exit the vehicle on the side where the barrier exists. Zoning recommends that you make the handicapped vehicle parking space eleven (11) foot wide with a five (5) foot wide access aisle, see ICC/ANSI A117.1-2003 Section 502.2. 7. D.S. 2-05.2.4.P The dimension for the wheel stop shown on the parking space detail is not shown correctly. See D.S. 3-05.2.3.C.2 and D.S. 3-05.0 Figure 5. 8. D.S. 2-05.2.4.P Per D.S. 3-05.2.3.C.1 A vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent vehicles from driving onto unimproved portions of the site. This said some type of barrier is required at the southeast end of the building where the pavement ends. 9. D.S. 2-05.2.4.Q Show the five foot access aisle on the bicycle detail, see D.S. 2-09.5.2. 10. D.S. 2-05.2.4.Q Identify the main entrance to the building so that the requirements of D.S. 2-09.4.1 can be verified. 11. D.S. 2-05.2.4.V If applicable show the location and type of postal service to be provided. 12. D.S. 2-05.2.4.V If applicable show the location and type of proposed signs (wall, free-standing, pedestal) on the plan. 13. The provided landscape plans do not match the provided development plan. There are numerous area where plants area shown in areas on the landscape plan where sidewalks, bicycle parking etc. are shown on the development plan. 14. It appears that the proposed 10,000 S.F. Food Service building is proposed to be built over a property line, which is not allowed. Demonstrate on the plan how the proposed building can be built on the plan without a lot split/lot combo being done. 15. Ensure that all changes to the development plan are reflected on the landscape plans. 16. Additional comments may be forth coming depending on how each comment has been addressed. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\cdrc\developmentplan\D08-0037dp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat/development plan and additional requested documents. |
| 08/25/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | 1. Add the CDRC development plan case number (D08-0037) along with any other related case numbers in the lower right hand corner of each sheet of the development plan, landscape plan and native plant preservation plan. 2. The bicycle parking is shown is a different location on the landscape plan from that shown on the development plan. Revise all elements of the plans to be correct and consistent. 3. The grading limits near the west property line of the site are shown in different locations on the native plant preservation plan and the development plan near the west side of the site. Revise all elements of all plans to be correct and consistent. |
| 08/25/2008 | CDRC1 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approved | CASE: D08-0037, LOT 34 BROWN / RITA RANCH: DEVELOPMENT PLAN COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS Vehicle Trip Generation: Daily: 28 PM Peak: 5 Please call if you have questions or need additional information. ------------------------------------------- KoSok Chae, Ph.D. 177 N. Church Ave., Suite 405 Tucson, AZ 85701 520-792-1093 x487 [tel] 520-620-6981 [fax] www.PAGnet.org |
| 09/05/2008 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | Laith Alshami, Engineering and Floodplain Review, 09/05/2008, TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: Lot 34 Brown/Rita Ranch D08-0037, T15S, R15E, SECTION 27 RECEIVED: Development Plan, Drainage Report and Landscape Plan on August 12, 2008 The subject submittal has been reviewed and it can not be approved at this time. Address the following comments before review can continue. Prepare a detailed response that explains the revisions that were made and references the exact location in the Drainage Report and on the Development Plan where the revisions were made: Drainage Report: 1. According to Brown/Rita Ranch Subdivision Final Plat General Notes 7-10, this development requires onsite detention/retention. Furthermore, the subdivision does not appear to be directly connected to Rita Ranch Regional Detention Basin through the existing drainage channel network, which means the lot drainage does not directly discharge into the said channels and consequently, detention can not be waived. Redo the drainage report and address provision of onsite detention/retention. 2. Provide all design calculations for any required drainage structures (i.e. scuppers, erosion control structures, channels, detention/retention basins, etc.). 3. Provide detention/retention basin maintenance checklist. 4. Address water harvesting requirements for this development. Development Plan: 1. The Drainage Report requires significant revisions that a complete Development Plan review can not be accomplished at this time. A cursory review has been conducted at this time. A full review will be conducted once the drainage report addresses the provision of detention/retention and additional comments might be offered at that time. 2. Complete the D (yr)-______ subdivision case number as required by D.S. 2-05.2.2.B.2. 3. Provide a brief legal description for the parcel in the Title Block D.S. 2-05.2.1.G.2. 4. Show, on the plan, the basis of bearing and the tie between one of the parcel corners to the basis of bearing (D.S. 2-05.2.3.A). 5. Show, on the plan, the basis of elevation. 6. Provide additional existing contour line elevations to clarify how the parcel slopes D.S. 2-05.2.3.E. 7. Provide all existing storm drainage facilities on and adjacent to the site, if applicable, D.S. 2-05.2.3.F. 8. Provide water harvesting areas and demonstrate how the drainage will be conveyed from the building roof and paved areas to the proposed water harvesting areas to maximize water harvesting (D.S. 2-05.2.4.H.2). 9. Show all proposed drainage structures including the number of proposed sidewalk scuppers, roof drains and roof drainage arrows, detention/retention areas, erosion control structures, etc. as required by (D.S. 2-05.2.4.H.3). 10. Indicate all proposed ground elevations at different points to provide reference to future grading and site drainage (D.S. 2-05.2.4.H.4). 11. According to D.S. 2-08.4.1.E. and D.S. 2-08.5.1.E.. 10-year flow has to be completely conveyed under sidewalks when the runoff crosses any sidewalk/walkway. Additionally, show the roof drainage proposed sidewalk scuppers where applicable. Please be advised that the 10-year flow requirement does not apply to roof drainage. Roof drainage has to be discharged in its entirety to avoid prolonged ponding on the roof that might cause the roof to collapse. Show the roof drainage direction and revise the Development Plan accordingly. 12. Provide maintenance access ramps for the proposed detention/retention basin. 13. All proposed work in the public right of way will require a right of way excavation permit or a Private Improvement Agreement. Contact Thad Harvison of Transportation Department Permit and Codes at 791-5100 for additional information. 14. Revise the Development Plan according to the Drainage Report revisions. 15. Additional information and details might be required with the Grading Plan and the PIA plans Landscape Plan: 1. Demonstrate compliance with water harvesting requirements. 2. Ensure that proposed landscaping does not conflict with the detention/retention basin inlet, outlet and maintenance access ramp. 3. Ensure that the proposed landscaping does not conflict with the sight visibility triangle. RESUBMITTAL REQUIRED: Revised Development Plan, Landscape Plan and Drainage Report |
| 09/05/2008 | TIM ROWE | PIMA COUNTY | WASTEWATER | Approved | September 3, 2008 To: JEFF STANLEY STANLEY ENGINEERING & DRAINAGE, INC. Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ___________________________ From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County Departments of Wastewater Management and Environment Quality Subject: LOT 34 - BROWN/RITA RANCH Dev. Plan - 1st Submittal D08-037 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan as submitted. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above-mentioned comments, please contact me. |
| 09/08/2008 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | DATE: September 08, 2008 TO: DSD_CDRC@ tucsonaz.gov FROM: Glenn Hicks Parks and Recreation 791-4873 ext. 215 Glenn.Hicks@tucsonaz.gov SUBJECT: D08-0037 Lot 34 Brown/Rita Ranch: Development Plan Review(8-12-08) Staff has no comments. |
| 09/08/2008 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D08-0037 Brown/Rita Ranch ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other CROSS REFERENCE: S99-049 NEIGHBORHOOD PLAN: Esmond Station GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 9/9/08 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment (XXXX) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies with Plan Policies ( ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: drcorral 791-4505 DATE: 9/02/08 |
| 09/09/2008 | ANDY VERA | ENV SVCS | REVIEW | Denied | 1. Sheet 1, increase curb return radius to allow collection vehicle to manuever on and off development without jumping curb or running over sidewalk. Recommend 25 ft radii. Collection vehicle requires a 36 ft inside and 50 ft outside turning radius. 2. Single solid waste enclosure shown would be better served if positioned 10 degrees more clockwise to allow adequate approach and maneuverability. However, recommend adding one single enclosure or designing one double wide enclosure to accomodate for refuse and recycle. 3. Sheet 3, masonry enclosure detail - Provide a post at the face of CMU on each side of the enclosure and mount gates to post to prevent damage to enclosure wall. 4. Fully dimension enclosure and call out side wall protectors /bollards so front side bollard is 2 ft to center of fron gates and rear side bollard is 4 ft to center of front side bollard. Please provide corrections on resubmittal. If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov |
| 09/10/2008 | FERNE RODRIGUEZ | COT NON-DSD | REAL ESTATE | Approved | No comment |
| 09/11/2008 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approv-Cond | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: D08-0037 LOT 34 BROWN/RITA RANCH/DEVELOPMENT PLAN DATE: 9/09/08 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: APPROVED PENDING: 1.) Label project number on all sheets. 2.) Include "Recorded in Pima County Maps & Plats Bk…." to legal description in title block. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 09/11/2008 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Passed | |
| 09/12/2008 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | |
| 09/15/2008 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#1202152 September 12, 2008 Stanley Engineering & Drainage Attn: Jeff Stanley PO Box 1888 Tucson, AZ 85702 To Jeff Stanley : SUBJECT: Lot 34 Brown/ Rita Ranch D08-0037 Tucson Electric Power Company has reviewed and approved the development plan submitted September 3, 2008. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. See TEP facilities map for proposed J2 sleeve and conduit installed in the field. The customer is responsible for the new trenching to relocate them as well as the relocation cost. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Ms. Mary Boice New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8732 Please call the area Designer Warren McElyea at (520) 918-8268, should you have any questions. Sincerely, Henrietta Noriega Office Specialist Design/Build hn Enclosures cc: City of Tucson, (Email only) W. McElyea, Tucson Electric Power |
| 09/15/2008 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 09/16/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 16, 2008 Jeff Stanley Stanley Engineering & Drainage, Inc. PO Box 1888 Tucson, Arizona 85702 Subject: D08-0037 Lot 34 Brown/Rite Ranch Development Plan Dear Jeff: Your submittal of August 12, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 6 Copies Revised Development Plan (ADA, Zoning, Landscape, Engineering, ESD, DSD) 4 Copies Revised Landscape Plan (Zoning, Landscape, Engineering, DSD) 2 Copies Revised NPPO Plan (Landscape, DSD) 2 Copies Revised Drainage Report (Engineering, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 792-0318 dp-resubmittal |