Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D08-0034
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/25/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
10/01/2008 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Approved | October 1, 2008 To: TANYA GRAHN PRESIDIO ENGINEERING Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ___________________________ From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County Departments of Wastewater Management and Environment Quality Subject: DOLLAR TREE STORE (LOTS 5 & 6 OF RETAIL CENTER VALENCIA/NEXUS LOTS 1-6) Dev. Plan – 2nd Submittal D08-034 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan as submitted. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above-mentioned comments, please contact me. |
10/03/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 2 OCTOBER 2008 D08-0034/DOLLAR TREE STORE - RESUBMITTAL REVIEWED BY RON BROWN ACCESSIBLE REVIEW - RESUBMITTAL 2006 IBC/ICC 117.1 DENIED 1. AT NW CORNER, MARKED CROSSING TO SAFEWAY, PROVIDE DETECTABLE WARNING AT SOUTH CURB RAMP, SHOW NEW CURB RAMP WITH DETECTABLE WARNING AT NORTH END OF CROSSING. RESUBMITTAL COMMENT: a. AS PER 2006 IBC/ICC-ANSI 117.1, SECTION 406.13.1, THE DETECTABLE WARNING STRIPS NEED BE ONLY 2' DEEP. REVISE ACCORDINGLY. b. THE EXISTING CURB RAMP AT SAFEWAY MUST COMPLY WITH CURRENT ACCESSIBILITY CODE, 2006 IBC/ICC-ANSI 117.1, SECTION 406. PLEASE SHOW LARGE SCALE DETAIL INCLUDING RAMP, DIMENSIONS, SLOPES (SPOT GRADES), DETECTABLE WARNINGS, ACCESSIBLE ROUTE AND MARKED CROSSING. THE EXISTING DRAWING AND DETAILING FOR THIS AREA IS NEITHER CLEAR NOR COMPLETE. 2. SHOW LOCATION OF ACCESSIBLE SIGNAGE ON SITE PLAN AND PROVIDE SIGNAGE DETAIL WITH "VAN ACCESSIBLE" SIGN ADDED. RESUBMITTAL COMMENT: OK 3. OK 4. NEW COMMENTS: a. DETAILS 5: DETECTABLE WARNINGS ARE NOT REQUIRED AT AN ACCESSIBLE PARKING AISLE. THIS IS AN OWNER OPTION AND IF ELECTED TO DO SO, IT NEED BE ONLY 2' DEEP. ADDITIONALLY, COT STANDARD DETAIL 207 IS ONLY FOR RIGHT OF WAY REQUIREMENTS. ALL ACCESSIBILITY COMPLIANCE WITHIN THE PROPERTY BOUNDARIES IS GOVERNED BY 2206 IBC/ICC-ANSI 117.1. CORRECT ALL DETAILS AND NOTES b. DETAIL 6: DETECTABLE WARNINGS NEED BE ONLY 2' DEEP. ADDITIONALLY, COT STANDARD DETAIL 207 IS ONLY FOR RIGHT OF WAY REQUIREMENTS. ALL ACCESSIBILITY COMPLIANCE WITHIN THE PROPERTY BOUNDARIES IS GOVERNED BY 2206 IBC/ICC-ANSI 117.1. CORRECT ALL DETAILS AND NOTES END OF REVIEW |
10/06/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | 1. A 6-foot high masonry screen wall is required to screen the loading zone from the R-1 zoned property to the south. Revise the wall along the south property line to be 6 feet high in this area. Label the wall height and the locations of transition from a height of 5 feet to a height of 6 feet on the landscape plan drawing. LUC Table 3.7.2-I |
10/09/2008 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
10/17/2008 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: D08-0034 Dollar Tree Store Development Plan TRANSMITTAL: 10/17/2008 DUE DATE: 10/23/08 COMMENTS: 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 07/14/09. 2. DS 2-05.2.2.3 In general note #1 list the subject to sections after the use as follows: "subject to: Sec. 3.5.9.2.C. and Sec. 2.5.3.6." 3. DS 2-05.2.4.A Provide the lot line, distance and bearing for the property line between lots 5 and 6 on the plan. 4. Please provide a dimensioned detail for class 1 and class 2 bicycle parking spaces within the indicated 6 X 14 area indicated on the plan. Review DS 2-09 for distances between bicycle racks. Minimum clearance at the side of a class two bicycle rack is 30". See DS 2-09 Figure 9. Clearly indicate where in the 6 X 14 area each of the class one bicycle lockers are located. The type of class two bicycle rack indicated is not an approved type of rack. Review DS 2-09 Figure 2 and 3 for acceptable type of class two bicycle racks. Revise detail. 5. Provide a note on the plan which states: "A vehicular and pedestrian cross access agreement has been recorded in docket 11298 page 910." If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\developmentplan\D08-0034dp.doc |
10/22/2008 | ANDY VERA | ENV SVCS | REVIEW | Denied | 1. Sheet 2, DP - The west side of double enclosure does not provide the required minimum 14 ft x 40 ft clear approach in front of the enclosure nor is their adequate manueverability without conflicting or jumping curb island to the immediate north in order for collection vehicle to position itself perpendicular to enclosure. DS 6-01.4.1.C Recommend modification of curb island to correct the conflict and approach issues. 2. Sheet 4, Dumpster enclosure detail - Enclosure requires a minimum of two side wall protectors (bollards) within the inside of each side wall and a 10 ft x 10 ft minimum clear between the rear and side wall protectors and the front gate/s for a single container area. Fully dimension enclsoure inside and out and include bollards spacing. DS 6-01.4.1.B & 6-01.4.2..C.2. Front side bollards should be dimensioned 2 ft from front of enclosure/gates and the rear side bollard 4 ft from front side bollard. 3. Gate post should be positioned at the face of the CMU wall not inside. Please provide corrections on resubmittal. If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov |
10/28/2008 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: D08-0034 DOLLAR TREE STORE/REVISED DEVELOPMENT PLAN DATE: 10/23/08 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Per comment letter dated 8/07/08: Delete administrative address information on sheet 1. (I have spoken with Patricia Gehlen regarding this. Please feel free to call her if you have any questions). |
10/30/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES October 30, 2008 Tanya Grahn Presidio Engineering 4582 North 1st Avenue Tucson, Arizona 85718 Subject: D08-0034 Dollar Tree Store Development Plan Dear Tanya: Your submittal of September 25, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 6 Copies Revised Development Plan (ADA, Landscape, Zoning, ESD, Addressing, DSD) 3 Copies Revised Landscape Plan (Landscape, Zoning, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 795-6747 dp-resubmittal |