Permit Number: D08-0033
Parcel: 13609019D

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D08-0033
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/17/2010 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/18/2010 MATT FLICK ENGINEERING REVIEW Approved PDSD Engineering has no objection or adverse comment regarding approval of the Development Plan (D08-0033).

PDSD Engineering has no objection or adverse comment regarding approval of the grading plan and SWPPP (T08BU01203).

Previously, PDSD Engineering had no objection or adverse comment regarding approval of the Scenic Corridor Zone overlay submittal (T08SA00244), rezoning (C9-08-10) of this site to C-2, and the revised drainage report.



Matt Flick, P.E.
Project Manager
Planning & Development Services
City of Tucson

Phone: (520) 837-4931
Fax: (520) 791-4340

Please visit our web site: www.tucsonaz.gov/dsd
02/18/2010 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved CDRC Review
Planning and Development Services Dept., Land Use Plan Review
D08-0033, Tucson Water Eastside Service Center, 3rd submittal
Comments Due: 3/17/10
Comments Submitted: 2/17/10

Items reviewed: Development Plan, Landscape Plan
Relevant Items: C9-08-10, Annexation Conditions

Comments:

The plans are approved. No resubmittal is required.



Reviewed by: J. Hershenhorn, 2/17/10


F:\Shardir\UPDfiles\Development Review\CASE_REVIEW\CDRC\2010 Cases\D08-0033b.doc
03/05/2010 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Tucson Water Eastside Service
Development Package (2nd Review)
D08-0033

TRANSMITTAL DATE: March 5, 2010

DUE DATE: March 17, 2010

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section conditionally approves the development package for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development package to verify that those changes do not affect any zoning requirements.

2. This comment was not addressed. Provide the following dimensions and information on the detail. Detail 15 Sheet 18 needs to addresses
a. D.S. 2-09.5.1.A seventy-two (72) inch length per bicycle parking space (Figure 9).
b. D.S. 2-09.5.1.B thirty-six (36) inch will be provide between a bicycle parking space and a perpendicular wall or other obstruction measured from the end of the bicycle rack to the perpendicular wall. A minimum of thirty (30) inches will be provided between a bicycle parking space and a parallel wall or other obstruction as measured from the side of the bicycle rack to the parallel wall (Figure 9).
c. D.S. 2-09.5.2 A five (5) foot wide access aisle measured form the front of rear of the seventy-two (72) inch long parking spaces will be provided.
d. Specify how lighting will be provided for the bicycle parking area, i.e. site lighting, exterior building lighting.
e. D.S. 2-01.3.9.G.5.d Provide an off-street bicycle parking detail; including materials for lighting, paving, and security; fully dimensioned layout; location; specific type of rack and the number of bicycles it supports; and the location and type of directional signage if required.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

Sshield1 on DS1/planning/New Development Package/ D08-0033

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and additional requested documents.
03/08/2010 RONALD BROWN ZONING HC REVIEW Denied As per previous comment number 5:

"Where the accessible route is designed to cross the East side of the loading dock (reference 13/D4), because this is a fork lift crossing area, please provide a marked crossing complete with detectable warnings as required by ADAAG, Sections 3.5 and 4.29.5."

Please provide a 3' deep x 4' wide detetcable warning strip on the top landing of the stairs just prior to stepping out onto the dock area, provide 4" wide painted diagonal stripes across the East side of the dock from the stair landing to the landing of the east side ramp, 4' wide. Then provide a 3' deep by 4' wide detectable warning strip at the edge of the ramp landing adjacent to the edge of the dock. This constitutes a marked crossing.

END OF COMMENTS
03/16/2010 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES


March 16, 2010

Kim Fernandez
ABA-Architects PC
1001 N. Alvernon Way
Tucson, Arizona 85711

Subject: D08-0033 Tucson Water East Side Service Center Development Package

Dear Kim:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Zoning, and Zoning HC, please submit the following documents for sign-off.

1 Rolled blue line COMPLETE SET of the Development Package, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews.

1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan.

Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your plans to the CDRC office for sign-off approval.

PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION.

Should you have any questions, please call me at 837-4917.

Sincerely,





John Williams
Planning Technician

All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/

Via fax: (520) 881-7505
03/16/2010 FRODRIG2 ENV SVCS REVIEW Approved Due Date Case Number Project Address
March 17, 2010 D08-0033 TUCSON WATER EASTSIDE SERVICE
Comments: APPROVED RESUBMITTAL DEVELOPMENT PLAN

Environmental Services Department
Development Plan Review
Reviewer: Tony Teran
Office Phone (520) 837-3706
E-mail: Tony.Teran @tucsonaz.gov