Permit Number: D08-0025
Parcel: 10309071D

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - CORE REVIEW

Permit Number - D08-0025
Review Name: RESUBMITTAL - CDRC - CORE REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/03/2009 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/18/2009 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. The native plant preservation plan must be drawn on an aerial photograph taken within a maximum of three years of submittal, at a minimum scale of 1"=60'. Revise sheet N-1 plan to include aerial photo base. DS 2-15.3.4.A.

2. The common name and botanical (latin) name of both genus and species must be included on the Native Plant Preservation Plan plant inventory on sheet N-1 per DS 2-15.B.1. Specify the palo verde species in the list.

3. Indicate the location of a temporary holding nursery to be used for salvaged plants on site. DS 2-15.3.4.A.5

4. Show a method and schedule for providing irrigation to salvaged plants in a temporary holding nursery area per DS 2-15.3.4.B.4.

5. The last line (plant number 30) of the plant inventory list on sheet N-1 is cut off at the bottom of the page and is illegible. Revise to show all information clearly.

6. Add the CDRC case number (D08-0025) along with any other applicable case numbers to all sheets of the landscape plan and native plant preservation plan. DS 2-07.2.1
03/19/2009 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 19, 2009


Tim O'Neill
O'Neill Engineering, LLC
2001 West Camelback Road
Phoenix, Arizona 85015

Subject: D08-0025 Goodmans Interior Structures- Warehouse Addition Development Plan

Dear Tim:

Your submittal of March 4, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and two sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Development Plan (Landscape, DSD)

2 Copies Revised Landscape Plan (Landscape, DSD)

2 Copies Revised NPPO Plan (Landscape, DSD)





Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager