Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D08-0022
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/02/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/06/2008 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 08/25/2008 | CDRC1 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approved | CASE: D08-0022, HOME DEPOT HOUGHTON: RESUBMITTAL- CDRC- DEV PLAN COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS Vehicle Trip Generation: Daily: 4,222 PM Peak: 347 Please call if you have questions or need additional information. ------------------------------------------- KoSok Chae, Ph.D. 177 N. Church Ave., Suite 405 Tucson, AZ 85701 520-792-1093 x487 [tel] 520-620-6981 [fax] www.PAGnet.org |
| 08/28/2008 | HEATHER THRALL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department, Plans Coordination Office FROM: Heather Thrall, Senior Planner PROJECT: D08-0020 Home Depot (at the Houghton Town Center) New Home Improvement Large Retail Establishment Development Plan, 2nd Review TRANSMITTAL DATE: August 28, 2008 DUE DATE: August 29, 2008 COMMENTS: 1. Per DS 2-05.2.4.K, regarding pedestrian circulation (accessibility separate review) A) per LUC 3.5.9.7.A.5 - sidewalks shall be provided along the full length of any building where it adjoins a parking lot at least eight (8) feet wide and unobstructed. Provide sidewalks along north, east and west side of building meeting the above and not impeded by sales area, pillars, building pop outs or tree wells. Provide width dimensions. B) sidewalks on all sides of buildings - along entire length of building -must be physically separated from adjacent PAAL, per DS 2-08.4.1. Provide curbing, bollards every 8 feet, or physically raise walk from asphalt with vertical curbing. The tree wells shown are not adequate safety features to prevent vehicles from crossing over sidewalks. 2. Per DS 2-05.2.4.P, regarding parking - A) provide wheel stop barriers in parking spaces abutting sidewalks - show on sheet DP3 and dimension on detail 4 of sheet 2. Appears on sheet 3 that 2.5 overhang noted now will impede the meandering sidewalk from being fully 8' wide. Revisit. 3. Per DS 2-05.2.4.Q, regarding bike parking - A) please clarify how the bike parking amounts for Home Depot were derived, as this site alone would have required 43 bike spaces. The amounts proposed - are they "left over" from the Houghton Town Center amount proposed? Clarify. B) per DS 2-08.3.1, provide pedestrian route - via a crosswalk that does not get impeded by a garden display area - to class 1 bike parking spaces 4. REGARDING SPECIAL EXCEPTION REQUIREMENTS OF CASE SE-06-23 A) provide a photometric plan with current Engineer stamp and signature, per condition 16 - spill over lighting must be checked. B) per condition 14, provide a copy of the staff accepted PDP to ensure outdoor sales areas shown on the plan match the areas on the PDP. 5. Note, further zoning review comments may be forthcoming, depending upon the responses provided. If you have questions on this review, I may be reached at Heather.Thrall@tucsonaz.gov or at 837-4951. ACCESSIBLE REVIEW FROM RON BROWN FOLLOWS: 28 AUGUST 2008 D08-022/HOME DEPOT AT HOUGHTON TOWN CENTER-RESUBMITTAL REVIEWED BY RON BROWN ACCESSIBLE REVIEW-RESUBMITTAL 2006 IBC/ICC 117.1 DENIED: SEE COMMENTS BELOW 1. Still need to show "Van Accessible" signage on pole. 2. Concerning the marked crossing at the front entry, provide a distinct marked crossing (color and texture) the same width (12') as the detectable warning at the parking spaces. Provide another detectable warning strip, 12' wide at the main entry concrete apron. 3. Need to fix the detectable warning strips of all marked crossings (5 in number) connecting to the concrete concourse of the building. A detectable warning strip must be added at the end of the marked crossing, the same width as the marked crossing. It can not be part of a continuous ribbon of detectable warning strips as designed. 4. No changes as per comment IIID. Separation from the accessible path way and the parking lot paving is a Development Standard and truncated domes are not acceptable as one of the methods of separation. Please refer to zoning comments. 5. The marked crossing detailed at the most Southerly corner of the building may not egress into a sidewalk sales area. Either relocate the marked crossing to the South West to miss the outdoor sales area or delete the outdoor sales area. END OF REVIEW C:\planning\cdrc\developmentplan\D08-0022 Home Depot HTC.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, and additional requested documents. |
| 08/28/2008 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#196028 August 28, 2008 Dear Mr. Sayler-Brown SUBJECT: HOME DEPOT D08-0022 Tucson Electric Power Company has reviewed and approved the development plan submitted August 18, 2008. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. All relocation costs will be billable to the customer. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Ms. Mary Boice New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8732 Please call the area Designer Steve Garcia at (520) 917-8739, should you have any questions. Sincerely, Henrietta Noriega Office Specialist Design/Build hn Enclosures cc:S. Garcia, Tucson Electric Power City of Tucson, (Email) |
| 08/28/2008 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | |
| 09/04/2008 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 09/08/2008 | CDRC1 | COT NON-DSD | REAL ESTATE | Denied | >>> Jim Stoyanoff 09/05/2008 8:07 AM >>> The deed is out for signature. I will send notification once the deed is recorded. |
| 09/15/2008 | PAUL MACHADO | ENGINEERING | REVIEW | Approv-Cond | To: Patricia Gehlen DATE: August 22, 2008 CDRC/Zoning Manager SUBJECT: 8880 S. Old Vail Rd., Home Depot Development Plan D08-0022 (Second Review) T15S, R15E, Section 35 RESUBMITTAL REQUIRED: None. Conditional approval granted. Development Plan: 1. Please include a response letter to the comments along with the corrected copies of the DP. 2. Include a copy of the approved "Houghton Town Center" DP (D06-0013) and the approved "Mass Grading Plan" (T08BU00493) for phase I with the re-submittal. If the Home Depot DP "stands alone" and/or is "not reliant" on the mass grading plan, then the DP becomes full code compliant including separate retention and detention basins. Include a copy of the approved "Mass Grading Plan". Per previous comment. 3. It is difficult to review this project without the benefit of the "Mass Grading Plan" (T08BU00493) for phase I to aid in reviewing the project. Hence, additional comments may be forth coming when the plans are re-submitted. Drainage Report: 1. The DR has been accepted be engineering. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/8880 S. Old Vail Rd_Home_Depot_CDRC 2 |
| 09/16/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 16, 2008 Thomas Sayler-Brown/Carolyn Lemmon SBBL Architecture & Planning 1001 North Alvernon Way #105 Tucson, Arizona 85711 Subject: D08-0022 Home Depot Houghton Development Plan Dear Thomas: Your submittal of August 4, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 4 Copies Revised Development Plan (Landscape, Real Estate, Zoning, DSD) 3 Copies Revised Landscape Plan (Landscape, Zoning, DSD) 2 Copies Revised NPPO Plan (Landscape, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 620-0535 |