Permit Number: D08-0019
Parcel: 14044009J

Address:
7648 S WILMOT RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D08-0019
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/14/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/15/2008 JIM EGAN COT NON-DSD FIRE Approved
08/19/2008 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: Holiday Inn Express - Wilmot & I-10
D08-0019
Development Plan (2nd Review)

TRANSMITTAL DATE: August 19, 2008

DUE DATE: September 12, 2008

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section conditionally approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements

2. Provide a copy of the signed approved tentative plat for this subdivision, S07-0025, with your next submittal. The provided tentative plat has not been signed by CDRC.

3. This comment has not been addressed. Per the development plan submitted for "EXCLUDED 1" there is PAAL access across the parcels lines. D.S. 2-05.2.4.D.3 Provide an overall plan showing how the proposed parking area access lanes (PAALs) that cross over property lines will work. Provide a copy of the cross access agreements required by the rezoning.

4. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\cdrc\developmentplan\D08-0019dp-2nd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents.
08/20/2008 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Denied August 19, 2008

To: TONY TSANG
A.C. TSANG ENGINEERING GROUP, INC.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

____________________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: HOLIDAY INN EXPRESS
Development Plan – 2nd Submittal
D08-019

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The improvement plan(G2007-085 ) does not show the BCS in the same location as shown on this plan. Either change this on the improvement plan or change it here on the development plan so that the two plans match. Also the lot lines and lot numbers shown on the improvement plan will need to be revised to match the Final Plat. Currently they do not match.

We have sent to your office via e-mail, a .pdf file containing a Sewer Service Agreement for the proposed number of wastewater fixture unit equivalents. Three originals will need to be printed out from this file for notarized signatures by the Owner of Record. The three signed originals of the Agreement must be returned to this office in order to satisfy the necessary requirements needed to approve the Mylars of thedevelopment plan .

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.


The next submittal of this project will be the third(3rd ) submittal. A check for the review fee of this submittal in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me .
08/28/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Approved
09/04/2008 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved
09/12/2008 ELIZABETH EBERBACH ENGINEERING REVIEW Denied DATE: September 12, 2008
TO: Patricia Gehlen; CDRC Coordinator
FOR: A. C. Tsang Engineering
SUBJECT: Wilmot/I-10 Holiday Inn Express 2nd submittal Engineering Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: D08-0019

SUMMARY: The revised Development Plan was reviewed by Engineering as part of the development for the Wilmot I-10 Commercial Center. The package included the Development Plan for the Holiday Inn Express, copies of the Tentative & Final Plat, the revised drainage report with response letter, and landscape plans. Development Services Department Engineering Division does not recommend approval of the Development Plan at this time. The drainage report was reviewed for Development Plan purposes only.

DEVELOPMENT PLAN COMMENTS:
1) City of Tucson Development Standards (DS) Section No. 2-05.2.3.I.1, 2-05.2.3.E.1, 2-05.2.4.H, & 10-02.2.3.1.5, 10-02.1.5: Address the remaining drainage comments for the development plan and drainage report:
a) Clarify pedestrian access area across basin showing grades/slopes. Revise elevations to reflect scupper crossing at pedestrian crossing for basin. Scuppers are required for sidewalks.
b) Clarify basin outlets for offsite discharge areas. Revise Basin A details on sheet 3.
c) Clarify types of off-site runoff acceptance points and/or on-site runoff discharge points on planview. It is unclear where the basin outlet flow is to be directed.
d) Show basin maintenance access on planview. Access ramp is in conflict with proposed outlet structure slopes. Revise basin design to match drainage report.
e) For the proposed roof drainage from north and south sides, show where sidewalk scuppers will be needed at north and south sides of sidewalks, and provide calculations in report.
f) Provide information on planview showing provision for water harvest areas. Show curb inlet and spot elevations or flow arrows where landscape areas receive water harvest stormwater flows.
g) Planview sheets for the development plan shall match drainage exhibits.
2) DS Sec.2-05.3.2.D, 2-05.1.1: In response letter, explain how Rezoning condition 26 is addressed for this project. Clarify access improvements to be completed prior to Holiday Inn Express C of O. Also address any revised TIA requirements and explain in response letter how the access will be provided for this use.
3) DS Sec.2-05.2.4.D.4: Access is indicated with pavements areas through this project, and only the north access easements is delineated and dedicated for such use. For this and other private easements, protective covenants establishing the right of access and incorporation of future phases into this project are required.
4) DS Sec.2-05.2.4.G: Further clarify the following easements:
a) Delineate clearly the easements on the plan view sheet to differentiate the private stormdrain, flowage, basin access & Maintenance Easement from other entities on the sheet.
b) Include the 24-ft Private Stormdrain, Flowage, Basin Access & Maintenance Easement.
5) DS Sec.2-05.2.4.L: Further clarify the following elements:
a) Clarify truncated domes for the proposed southside of the pedestrian accessible walkway at the south pavement area.
b) Clarify widths of all pedestrian walkways and sidewalks. Not all are labeled with widths.
c) Clarify locations of all curb (with type of curb) on planview.
d) Clarify elevations for each element, distinguishing between top of curb and pavement elevations. This may be clarified with legend or planview.
6) DS Sec.2-05.2.4.R: Show and dimension SVT's for all access points on planview.


Submit the revised Development Plan addressing all of the comments. Include the revised development plan, the revised drainage report, the revised Final Plat block plat, copy of rezoning conditions, copy of cross access agreement, and response letter thoroughly explaining each comment. If you have questions or would like to set up a meeting, call me at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
09/15/2008 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207


JENNIFER STEPHENS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL
SUBJECT: D08-0019 HOLIDAY INN EXPRESS/REVISED DEVELOPMENT PLAN
DATE: 9/12/08



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.




ES
09/15/2008 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#195232 September 12, 2008


A.C.Tsang Engineering Group
Attn: Antony C.Tsang
4626 E. Fort Lowell Ste S
Tucson, AZ 85712

To Antony Tsang:

SUBJECT: Holiday Inn Express - Resubmittal
D08-0019


Tucson Electric Power Company has reviewed and approved the development plan submitted September 3, 2008. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. The customer is responsible for the new trenching to relocate them as well as the relocation cost.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Ms. Mary Boice
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8732

Please call the area Designer Warren McElyea at (520) 918-8268, should you have any questions.


Sincerely,



Henrietta Noriega
Office Specialist
Design/Build
hn
Enclosures
cc: City of Tucson, (Email only)
W. McElyea, Tucson Electric Power
09/16/2008 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved DSD_CDRC.DSPO2.CHDOM2@tucsonaz.gov
09/17/2008 ANDY VERA ENV SVCS REVIEW Approv-Cond 1. Solid waste enclosure on the north side does not provide the minimum required 14 ft x 40 ft approach nor allow the collection vehicle to position itself perpendicular to the enclosure. Enclosure needs to be positioned at a 30 degree angle and demonstrate adequate maneuverability into approach.

2. Recommend moving the north enclosure and positioning it directly west of the south enclosure so face each other in a mirror image perspective. This will allow a more adequate central location for collection and user.

Please provide corrections as noted above.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
09/17/2008 JOSE ORTIZ COT NON-DSD TRAFFIC Denied September 17, 2008
ACTIVITY NUMBER: D08-0019
PROJECT NAME: Holiday Inn
PROJECT ADDRESS: 7648 S Wilmot Rd
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the Development Plan; therefore a revised Development Plan is required for re-submittal. The following items must be revised or added to the development plan.

1. Include a response letter with the next submittal that states how all comments have been addressed.

2. The development plan needs to schematically illustrate the required off-site improvements that will be designed for in the private improvement agreement (PIA). DSD requires that any off-site improvements associated with a development be illustrated on the development plan. Again, a schematic layout of the off-site improvements are acceptable at this time, but need to be illustrated to ensure that there are no adverse impacts to the adjacent properties.


If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov
09/18/2008 PGEHLEN1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed
09/24/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 24, 2008

Antony C. Tsang
A.C. Tsang Engineering Group, Inc.
4626 East Fort Lowell Road, Suite S
Tucson, Arizona 85712

Subject: D08-0019 Holiday Inn Express Development Plan

Dear Tony:

Your submittal of August 14, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Development Plan (Wastewater, Zoning, Traffic, ESD, Engineering, DSD)

3 Copies Revised Landscape Plan (Zoning, Engineering, DSD)

2 Copies Revised Drainage Report (Engineering, DSD)

2 Copies Cross Access Agreement (Engineering, DSD)





Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 325-0979