Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: D08-0011
Parcel: 140410220

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D08-0011
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/25/2008 ANDY DINAUER START PLANS SUBMITTED Completed
08/19/2008 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: Airport Distribution Center-Resubmittal
D08-0011


Tucson Electric Power Company has reviewed and approved the development
plan submitted July 25, 2008.


Alberta Adrian
Office Specialist
918-8347 Ofc.
793-7504 Pgr.
08/21/2008 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond ACTIVITY: D08-0011
SUBJECT: Airport Distribution Center 3rd submittal Engineering Review
ADDRESS: 6750 S Palo Verde Rd
FEMA: 2243K, Zone X-Unshaded
WATERSHED: Rodeo Wash Watershed
BASIN AREA: Critical basin management area
REVIEWER: Elizabeth Eberbach, PE

SUMMARY: The resubmittal Development Plan package, including the revised Development Plan, Landscape documents, a copy of the DOWL Drainage Report, and response letter was reviewed by Development Services Department Engineering. Development Services Department Engineering recommends conditional approval of the Development Plan. The utility easement comment may be addressed at mylar submittal stage. The Drainage Report was reviewed for development plan purposes only.

DEVELOPMENT PLAN CONDITION OF APPROVAL:
1) DS Sec.2-05.2.3.B, 2-05.2.4.G: Clarify the perimeter easements by labeling type and width of easements on sheets 2 and 3.

Resubmittal is required to address the above item, but may be addressed at mylar submittal stage. Submit a revised Development Plan, any other supporting documentation, and a response letter. If you have questions, you may call me at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department
08/22/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES


August 22, 2008

Chuck Schuiteman, AIA
GDA
250 South Craycroft Road, Suite 200
Tucson, Arizona 85711

Subject: D08-0011 Airport Distribution Center Development Plan

Dear Chuck:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line comments, please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan.
AND
1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html.

Should you have any questions, please call me at 837-4919.


Sincerely,



Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 881-4390
dpapproved