Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D08-0007
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/18/2008 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 09/22/2008 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 09/26/2008 | CDRC1 | PIMA COUNTY | WASTEWATER | Approved | September 26, 2008 To: Grant Gete CDG Architects Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Chandubhai C Patel, P.E., Civil Eng. Manager Development Review Division ( Wasterwater) Subject: El Rio Health Center Southeast Clinic Dev. Plan -3rd Submittal D08-007 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The PDEQ the PCRWRD hereby approve the above referenced submittal of the development plan as received by us on September 16, 2008. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. |
| 09/29/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Approved | |
| 10/14/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/14/2008 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 10/14/2008 | PAUL MACHADO | ENGINEERING | REVIEW | Approv-Cond | To: Patricia Gehlen DATE: October 9, 2008 CDRC/Zoning Manager SUBJECT: El Rio Health Ctr., 6950 E. Golf Links Rd. Development Plan D08-0007 (Third Review) T14S, R15E, Section 30 RESUBMITTAL REQUIRED: None. Development Plan: 1. Conditional approval by engineering providing the following comments have been addressed. 2. (last/current review) The submittal differs from the Preliminary Development Plan (PDP) approved August 15, 2005. The use and building sizes changed, which may require Mayor & Council to revisit the rezoning case and conditions for C9-05-21. Send a letter to the Director of the Department of Urban Planning and Design (DUPD), asking if this project is a major change to the PDP and requires Mayor & Council attention. For staff to accept the resubmittal in for review, a letter of advisement from the DUPD Director is required. Zoning reviewed the plan in the event DUPD accepts the proposal. Should rezoning conditions change, note them on the resubmittal. Your response to the above stated a letter would be provided from DUPD. Drainage Report: 1. The DR has been accepted for DP review only. If you have any questions, I can be reached at 837-4932 or Paul.Machado@ci.tucsonaz.govs Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/6950 E. Golf Links Rd. CDRC_3 |
| 10/15/2008 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: D08-007 El Rio Health Center Southeast Clinic, 6950 E. Golf Links 3rd Review, Development Plan, rezoning case C9-05-21 TRANSMITTAL DATE: October 14, 2008 DUE DATE: October 15, 2008 COMMENTS: 1. Per the DUPD director the change of PDP is considered minor and no additional conditions have been added to the rezoning conditions authorized by the Mayor and Council. However this plan was previously reviewed based on the new use of Medical Service Outpatient. I have requested that Ronald Brown Commercial plans reviewer and HC/ADA expert been given an opportunity to review the plan based on the change of use. Please address Ron's comments in the same manner as all comments from all review agencies are addressed. Previous Comment: (last/current review) The submittal differs from the Preliminary Development Plan (PDP) approved August 15, 2005. The use and building sizes changed, which may require Mayor & Council to revisit the rezoning case and conditions for C9-05-21. Send a letter to the Director of the Department of Urban Planning and Design (DUPD), asking if this project is a major change to the PDP and requires Mayor & Council attention. For staff to accept the resubmittal in for review, a letter of advisement from the DUPD Director is required. Zoning reviewed the plan in the event DUPD accepts the proposal. Should rezoning conditions change, note them on the resubmittal. Your response to the above stated a letter would be provided from DUPD. Please include with resubmittal. 2. I have seen Ron Brown's comments relative to Accessibility and would encourage you to take the opportunity to discuss the comments he has placed in permits plus before re-submitting any plans through the CDRC process. Several comments have been made and can be of major concern and must be addressed by revising the plan. 3. Zoning conditionally approves the development plan barring any changes necessary due to other review agency comments that affect zoning requirements. |
| 10/15/2008 | FERNE RODRIGUEZ | COT NON-DSD | REAL ESTATE | Denied | Please provide title reports for the three new parcels. Also, new legal descriptions and sketch for the right of way dedication based on the new property lines. Sincerely, Jim Stoyanoff Property Agent Real Estate Division City of Tucson 201 N. Stone Ave. 6th Fl. Tucson, Arizona 85701 (O) 520.837.6719 (F) 520.791.5641 Jim.Stoyanoff@tucsonaz.gov |
| 10/15/2008 | RBROWN1 | ADA | REVIEW | Denied | 15 OCTOBER 2008 D08-0007/EL RIO HEALTH CENTER - SOUTHWEST CLINIC REVIEWED BY RON BROWN ACCESSIBLE REVIEW 2006 IBC/ICC 117.1 DENIED: SEE COMMENTS BELOW I. SHEET 1 of 4 A. NOTE 10: CHANGE GOVERNING ACCESSIBILITY CODE TO 2006 IBC, CHAPTER 11 AND ICC, ANSI 117.1 FOR PRIVATE PROPERTY. ADD THE FOLLOWING: "GOVERNING ACCESSIBILITY CODE FOR PUBLIC RIGHT OF WAY IS COT DOT". B. ALL ACCESSIBLE SIGNAGE TO BE AS PER "PARK WISE" REQUIREMENTS. II. SHEET 2 of 4: A. SHOW RAMPS, SIGNAGE AND LOCATE "VAN ACCESSIBLE" SPACES FOR ALL ACCESSIBLE PARKING. PROVIDE A SURFACE MOUNTED CURB AT ALL ACCESSIBLE ROUTE AREAS THAT ARE FLUSH WITH THE VEHICLE AREAS EXCEPT AT PARKING AISLE ACCESS. REFERENCE ZONING REQUIREMENTS FOR ACCESSIBLE ROUTE . B. THE NORTHERLY RAMPS FOR BOTH MARKED CROSSINGS DO NOT WORK, REDESIGN. PROVIDE A LARGE SCALE DETAIL SHOWING ALL DIMENSIONS, SLOPES, DETECTABLE WARNINGS AND ETC TO COMPLY WITH ANSI 117.1, SECTION 406. C. THE MOST EASTERLY MARKED CROSSING DOES NOT WORK. STRAIGHTEN OUT CROSSING AND PROVIDE NEW RAMP SYSTEM AS PER ANSI SECTION 405. D. PROVIDE A NEW REFERENCE FOR ALL INTERIOR SITE CURB AND SIDEWALK RAMPS ON PRIVATE PROPERTY TO REFERENCE COMPLIANCE WITH ANSI SECTION 405 AND/OR 406 AND NOT DOT 207. III. SHEET 3 of 4: A. DETAIL "A": SHOW 5' WIDE ACCESSIBLE ROUTE AND SIDEWALK RAMPS. PROVIDE A SURFACE MOUNTED CURB AT ALL ACCESSIBLE ROUTE AREAS THAT ARE FLUSH WITH THE VEHICLE AREAS EXCEPT AT PARKING AISLE ACCESS. REFERENCE ZONING REQUIREMENTS FOR ACCESSIBLE ROUTE. I SUGGEST A MEETING TO REVIEW MY COMMENTS PRIOR TO SUBMITTAL OF FINAL MYLARS. END OF REVIEW |
| 10/15/2008 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approv-Cond | DATE: October 10, 2008 TO: DSD_CDRC@ tucsonaz.gov FROM: Glenn Hicks Parks and Recreation 791-4873 ext. 215 Glenn.Hicks@tucsonaz.gov CC: Patricia Gehlen SUBJECT: D08-0007 El Rio Health Center SE Clinic: Resubmittal(9-17-08) Conditionally approved, provided trail easement note meeting Parks and Recreation and Real Estate approval is shown on the final plat. |
| 10/15/2008 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approv-Cond | PARKS AND RECREATION DEPARTMENT COMMENTS City of Tucson CDRC – Community Design Review Committee CASE NAME & NUMBER: D08-0007, El Rio Health Center SE Clinic: DP Submittal #: 3 COMMENTS SENT: 11/19/08 (based on a walk-through review) Items reviewed: Development Plan and trail easement language Related: rezoning - C9-05-21 CDRC – WASH Ordinance review land use plan(s) – South Pantano Area Plan Parks and Recreation Department Staff has reviewed this proposal and offers the following comments: Plans are APPROVED – No additional submittal is required. REVIEWER: Joanne Hershenhorn DATE: 11/18/08 S:\PARKS_AND_RECREATION_DEPT\REVIEW_COMMENTS\CDRC_Cases\2008_ReviewsD08-0007b_El_Rio_Health_Center_SE.doc |
| 10/31/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES October 31, 2008 Grant Gete CDG Architects 2102 North Country Club Road, #9 Tucson, Arizona 85719 Subject: D08-0007 El Rio Health Center Development Plan Dear Grant: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on line comments, please submit the following documents for sign-off. 1 Rolled blueline COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. AND 1 Rolled blueline set of the Development Plan. AND 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. The extra rolled blueline set that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the rolled blueline to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. PRIOR TO SUBMITTING THE FINAL PLANS TO THE CDRC OFFICE, THEY MUST BE REVIEWED AND APPROVED BY PARKS AND RECREATION. THE APPROVAL MUST BE IN WRITING (E-MAIL IS OKAY). PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 798-3341 |