Permit Review Detail
Review Status: Completed
Review Details: REVISION - DEV PLAN
Permit Number - D08-0005
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/25/2010 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/01/2010 | MATT FLICK | ENGINEERING | REVIEW | Approved | PDSD Engineering has no objection or adverse comment to approval of the revised (Rev. #4) development plan. |
| 03/01/2010 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 03/03/2010 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
| 03/04/2010 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: La Curacao Department Store Site Plan - Revision #4 (1st Review) D08-0005 TRANSMITTAL DATE: March 4, 2010 DUE DATE: March 11, 2010 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along with a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. D.S. 2-05.3.9.G.5.a Sheet 2A The parking calculation appears to be opposite of the proposed phasing. The parking calculation shows a single building under PHASE 1 of 90,312 sq. ft. and PHASE 2 shows a total square footage of 107,095. Based on the drawings PHASE 1 should account for the 107,095 sq. ft. of building and PHASE 2 should account for the entire site. Please clarify the phasing and parking calculation. 2. D.S. 2-05.3.9.G.5.a Sheet 18 provide a vehicle parking space dimension from the handrail along the east side of the trash compactor. Per D.S. 3-05.2.1.3 When the side(s) of a parking space abuts any vertical barrier over six (6) inches in height, other than a vertical support for a carport, the required width for the space is ten (10) feet to provide extra width to allow passengers to enter and exit the vehicle on the side where the barrier exists. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ d08-0005-REV4.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package. |
| 03/09/2010 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#193349 March 5, 2010 Stantec Consulting Inc. Attn: Mathew Connors 201 N Bonita Ave, 101 Tucson, Arizona 85745 Dear Mr. Connors : SUBJECT: La Curacao Department Store D08-0005 Tucson Electric Power Company has reviewed and approved the development plan submitted March 1, 2010. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation and removal of Overhead facilities will be billable to the customer. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Mr. ricahrd Harrington New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8726 Should you have any technical questions, please call the area Designer Mike Kaiser at (520) 918-8244. Sincerely, Elizabeth Miranda Office Support Specialist Design/Build lm Enclosures cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email) M. Kaiser, Tucson Electric Power |
| 03/10/2010 | FRODRIG2 | ENV SVCS | REVIEW | Approved | Due Date Case Number Project Address March 11, 2010 D08-0005 La Curacao Department Store Comments: Approved Development Plan Environmental Services |
| 03/10/2010 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Phase 1, as proposed, does not allow for use of the Pima County Trail along the Tucson Diversion Channel. Revise the plans to ensure that this asphalt trail remains safe and functional until the Phase 2 improvements are completed. Provide information on any necessary temporary improvements or obtain approval to close the trail until Phase 2 construction is completed. |
| 03/15/2010 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 03/16/2010 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES March 16, 2010 Corey Thompson Stantec Consulting, Inc. 201 N. Bonita Avenue #101 Tucson, Arizona 85745 Subject: D08-0005 La Curacao Department Store Development Package Dear Corey: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Zoning, please submit the following documents for sign-off. 1 Rolled blue line COMPLETE SET of the Development Package, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your plans to the CDRC office for sign-off approval. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4917. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/ Via fax: (520) 750-7470 |