Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D08-0001
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/15/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/19/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 19, 2008 Nathan Menard Mulvanny G2 Architecture 18200 Von Karman Ave., Suite 910 Irvine, California 92612 Subject: D08-0001 Costco Addition Development Plan Dear Nathan: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line comments, please submit the following documents for sign-off. 1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). AND 1 Double Matte right-reading Océ or Photo Mylar of the Development Plan. AND 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (949) 705-0727 dpapproved |
| 09/19/2008 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Costco Addition D08-0001 Development Plan (4th Review) Revised TRANSMITTAL DATE: September 19, 2008 DUE DATE: October 13, 2008 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section conditionally approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 1) Zoning acknowledges that a Development Standards Modification Request (DSMR) 08-38 was approved to allow the use of the pedestrian circulation location within the right-of-way (ROW) for the required pedestrian circulation to connect to the pedestrian circulation on site. This DSMR did not eliminate the requirement for the sidewalk between the proposed parking and the proposed receiving area. Also as zoning looks at loading spaces as a parking space, per D.S. 2-08.4.1.F Sidewalks or pedestrian refuge areas may not be located between any motor vehicle parking space and the PAAL providing access to that space. The proposed striped area that runs between the PAAL and the proposed "12 x 35 BREAD RAMP LOADING SPACE" cannot be located as shown on the plan. D.S. 2-05.2.4.K To clarify the comment in regards to the required sidewalk along the west side of the proposed receiving area expansion between the building and the vehicle parking spaces. The ramp, as it does not provide access from the vehicle parking spaces, does not count as the required pedestrian circulation. There for this plan does not provide the required pedestrian circulation. A DSMR typically does not allow for elimination of a Development Standard. If the DSMR is approved provide the DSMR number, date of approval and any conditions of approval on the development plan. The development plan cannot be approved until the DSMR is approved. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. I:\planning\cdrc\developmentplan\2008\D08-0001-4th.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents. |