Permit Number: D07-0047
Parcel: 14118530A

Review Status: Completed

Review Details: DEVELOPMENT PLAN

Permit Number - D07-0047
Review Name: DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/14/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/21/2007 TIM ROWE PIMA COUNTY WASTEWATER Denied December 4, 2007

To: Victor Bolduc
Paragon Architects

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

___________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: Accuduct Rita Ranch Commerce Center
Dev. Plan - 1st Submittal
D07-047


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

This project will be tributary to the Roger Road Wastewater Treatment Facility via the Southeast Interceptor. Obtain a letter from the PCWMD's Development Services Section, written within the past 90 days, stating that treatment and conveyance system capacity for the project is available in the downstream public sewerage system and provide a copy of that letter to this office. The required form to request such a letter may be found at:

http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf.

The development plan for this project cannot be approved until a copy of this letter has been received by this office.

All Sheets: Show the jurisdiction’s case number, D07-0047, in or near the title block of each sheet. This case number should be shown larger and bolder than any associated cross-reference numbers.

Sheet 1: Revise General Note #33 to read as follows:

THE ON-SITE SANITARY SEWERS, EXCEPT PUBLIC SEWERS WITHIN PUBLIC SEWER EASEMENTS OR RIGHTS-OF-WAY, WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS, AND IN ACCORDANCE WITH AN APPROVED OPERATION AND MAINTENANCE PLAN, IF REQUIRED. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

Sheet 1: Add a General Note that states:

THE LANDSCAPING WITHIN ALL PUBLIC SEWER EASEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4.

Sheet 1: Add a Permitting Note that states:

NO PERMITS FOR PERMANENT STRUCTURES (I.E., MASONRY WALLS, FENCES, ETC.) ON OR THROUGH THE PUBLIC SEWER EASEMENT WILL BE ISSUED WITHOUT SEPARATE WRITTEN CONSENT OF PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

Sheet 2: If you are proposing to fence off the property including the public sewer easement, a gate will be required in order to maintain access to the public sewer line. Contact Ilene Deckard of the PCWMD Development Services Section (520)740-6544.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $100.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above-mentioned comments, please contact me.
11/26/2007 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved ADOT has NO COMMENT on this project
D07-0047
PARAGON ARCHITECTS, LLC
ACCUDUCT MANUFACTURING

--------------------------------------------------------


Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
11/27/2007 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)
FROM: Gary Ault, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: November 20, 2007


RE: Assessor’s Review and Comments Regarding DEVELOPMENT PLAN
D07-0047 ACCUDUCT MANUFACTURING

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS:
THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL ROSANNA WERNER AT 740-4390



ROSANNA WERNER
11/27/2007 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: November 27, 2007

TO: DSD_CDRC@ tucsonaz.gov

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov


SUBJECT: D07-0047 Accuduct Manufacturing: Development Plan 11-15-07

Parks and Recreation has no comments on this project.
11/28/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
11/29/2007 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D07-0047 ACCUDUCT MANUFACTURING/DEVELOPMENT PLAN
DATE: 11/29/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Delete 9568 from Address. This project will use only one address: 9538 E. Old Vail Rd. (Title Block and Location Map).




es
11/30/2007 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. Add the CDRC Development Plan case number (D07-0047), the annexation case number (C9-84-84) and any other relevant case numbers to all sheets of the Development Plan, Landscape Plan and Native Plant Preservation Plan.

2. Within vehicular use areas every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a. One of the disabled parking spaces near the center of the site is not located within 40 feet of a canopy tree. Revise as required.
11/30/2007 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
12/03/2007 ANDY VERA ENV SVCS REVIEW Denied 1. Seet 1, DP1- Trash enclosure detail
Show spacing dimensions for bollards/wall protectors. Require minimum, (2) front side bollards 2 ft from front gates; (2) rear side bollards 4 ft to center of front side bollards; (3) rear bollards 4 ft to center on each side of center bollard.

2. Access and maneuverability to single refuse/recycle enclosure okay. However, one single enclosure for this type of development not adequate. Recommend adding a double sized enclosure type to the south or west corner of building rear to ensure adequate service volume and access for development.

Please provide corrections on resubmittal.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
12/03/2007 JIM EGAN COT NON-DSD FIRE Denied An automatic sprinkler system is required. Put the correct key notes on for fire riser.
12/04/2007 FRODRIG2 OTHER AGENCIES PIMA ASSN OF GOVTS Approved Recall last email with this case number. It is wrong one!



The following is correct!!



CASE: D07-0047, ACCUDUCT MANUFACTURING: DEVELOPMENT PLAN

COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS




Vehicle Trip Generation: Daily: 226 PM Peak: 44



Please call if you have questions,



Aichong Sun

Pima Association of Governments

177 N. Church Ave, #405

Tucson, AZ 85701

Tel: (520) 792-1093, Fax: (520) 620-6981

Web: www.PAGnet.org and www.RTAmobility.com
12/04/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D07-0047 Accuduct Manufacturing 12/03/07

() Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-84-84, C12-95-33

NEIGHBORHOOD PLAN: Esmond Station

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY: 12/13/07

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
(X) Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: drcorra 791-4505 DATE: 11/25/07
12/04/2007 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#190641 December 4, 2007




Dear Mr. Bolduc:

SUBJECT: Accuduct Manufacturing
D07-0047


Tucson Electric Power Company has reviewed and approved the development plan submitted November 27, 2007 It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. All relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Ms. Mary Boice
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8732

Please call the area Designer Steve Garcia at (520) 917-8739, should you have any questions.


Sincerely,



Henrietta Noriega
Office Specialist
Design/Build
hn
Enclosures
cc:S. Garcia
12/07/2007 MATT FLICK ENGINEERING REVIEW Denied D07-0047 - Accuduct Manufacturing - Rita Ranch Commerce Center

DSD Engineering has reviewed the development plan, landscape plan and drainage report and found them unacceptable for approval. The following comments are offered:

DRAINAGE REPORT:

1. The use of the 0.7 Contributing Area Factor has not been justified. The factor is typical of moderately urban conditions and is generally not reflective of industrial development. Please use a coefficient for industrial development.

2. Encroachment is shown in the platted floodplain shown on the plat for Rita Commerce Center (C12-95-33). General Note #12 B on said plat prohibits development in this area unless an analysis shows no increase in post-development flows. This includes any increases in flows, particularly at the UPRR culvert, that may be caused by loss of storage volume caused by encroachment. Provide an analysis showing no increase in flow or remove the encroachment from the platted floodplain.

3. Please revise the location map to reflect the location of this development, not the Direct TV site.

4. The Development Plan and Landscape Plans indicate that this development is to be phased. Please indicate that all development phases can be accommodated drainage-wise.

LANDSCAPE PLANS:

1. Sheet L3 - There is a proposed concrete channel along the eastern property line. Please indicate channel location and locate vegetation to avoid adverse effects upon the channel.

2. Sheet L4 - The development plan indicates 2 spillways into the detention basin that are not indicated on this sheet.

3. Sheet L4 -- The drainage report and development plan call out the basin bottom elevation as 52, not 53.

4. Sheet L4 - There is a proposed concrete channel along the eastern property line. Please indicate channel location and locate vegetation to avoid adverse effects upon the channel.

5. Sheet L7 - Please fill in the right-of-way width.

DEVELOPMENT PLAN:

1. General Note #5 - Please indicate the specific monumentation used. Most monumentation for the Rita Ranch Commerce Center plat was set, not found, and may not reflect the bearings shown on the plat.

2. General Note #6 - Please add that this location is found on the north side of Old Vail Road.

3. Sheet 2 - Please indicate the weir location and provide a detail for the weir (similar to that contained in the drainage report).

4. Sheet 2 - Please indicate the location of the concrete channel to be locate near the eastern property line and indicate its presence in Section 3B.

5. Sheet 2 - Please indicate the location of the slotted drain and indicate its location in Section 3A (or otherwise indicate what it'll look like).

6. Sheet 2 - Please indicate the existing scupper to be removed.

7. Sheet 2 - Please indicate the scupper to be installed and call out a description or show a detail.

RESUBMITTAL REQUIRED:

Drainage Report
Landscape Plan
Development Plan

Matt Flick, P.E.
Engineering Manager
Development Services Department
City of Tucson

Phone: (520) 837-4931
Fax: (520) 879-8010

Please visit our web site: www.ci.tucson.az.us/dsd
12/07/2007 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: D07-0047
Accuduct Manufacturing
Development Plan

TRANSMITTAL: 12/07/07

DUE DATE: 12/13/07

COMMENTS:

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 12/12/08.

2. DS 2-05.2.2.A.1 Provide the name, address, and telephone number of the developer of this project.

3. DS 2-05.2.2.B.2 Case number D07-0047 has been assigned to this development plan (DP). Please place this number in the right corner of all sheets of the development plan, landscape plan, NPPO, and any other associated sheets.

4. DS 2-05.2.4.A A tax parcel combination will be required in order combine the two lots into one lot. Provide documentation indicating that the tax parcel combination has been completed.

A covenant regarding the development and use of real property is required to be completed and recorded. Provide on the plan the recording docket and page information and provide a copy of the covenant with the next submittal. A copy of the required covenant can be obtained at the front counter at DSD.

5. DS 2-05.2.4.Q The required number of class one bicycle parking spaces is incorrect. Per LUC Sec. 3.3.4 the required number of class one spaces is 90 percent of the total required spaces. Plan indicates 8 spaces provided, 9 are required. Revise.

A 5' access aisle is required at the class two bicycle parking spaces. The plan indicates only a 4' area available for the access aisle. Turning the bicycle parking spaces 90 degrees would provide the required access aisle.

6. DS 2-05.2.4.W Indicate the locations and types of proposed signs (wall, freestanding, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Also indicate if there are existing billboards on site. Billboards will be required to meet all LUC requirements as stated in LUC Sec. 3.5.4.26. If none exists please state so.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

TLS C:\planning\cdrc\developmentplan\D07-0047dp.doc
12/11/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 11, 2007

Victor Bolduc/Alisha Hardin
Paragon Architects, LLC
2210 East Fort Lowell Road, Suite 100
Tucson, Arizona 85719

Subject: Accuduct Manufacturing Development Plan

Dear Victor/Alisha:

Your submittal of November 15, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

9 Copies Revised Development Plan (Wastewater, Addressing, Landscape, Fire, ESD, Engineering, Zoning, Real Estate, DSD)

4 Copies Revised Landscape Plan (Landscape, Engineering, Zoning, DSD)

2 Copies Revised Drainage Report (Engineering, DSD)

2 Copies Lot Combination Form (Zoning, DSD)




Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 382-0075
12/11/2007 CDRC1 COT NON-DSD REAL ESTATE Denied Remove the blank Docket and Page for the combo request on page two of the development plan (center of the future development site). The lot combo request is simply a Pima County Assessors note on the tax information sheet combining parcels 141-18-5300 and 141-18-5310 and not a recorded document.

The new 6" public water line (Key note 52) should have already been submitted to Tucson Water for review as a water plan with the water line easement request being forwarded to the Real Estate Division as a Work Order.