Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D07-0040
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/04/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/13/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D07-0040 Valencia Dental Center Development Plan TRANSMITTAL DATE: December 11, 2007 DUE DATE: January 3, 2008 COMMENTS: The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 1. The truncated domes are to extend across the entire length of the access aisle per ADA Federal requirements. Please revise plan view and detail 6/2. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D07-0040dpr1.doc |
| 12/21/2007 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: December 21, 2007 SUBJECT: Valencia Dental Center Development Plan- 3rd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 295 W Valencia Road, T15S R13E Sec13 Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: D07-0040 SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised Development Plan, Drainage. Engineering Division recommends approval of the Development Plan at this time. Any changes required by other Development Services Departments will require a separate review through Engineering Section. For any questions or to schedule a meeting call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 12/21/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES December 21, 2007 Laura Lohner Stantec Consulting Inc. 201 North Bonita Avenue, Suite 101 Tucson, Arizona 85745 Subject: D07-0040 Valencia Dental Center Development Plan Dear Laura: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line comments, please submit the following documents for sign-off. 1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). AND 1 Double Matte right-reading Océ or Photo Mylar of the Development Plan. AND 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 750-7470 dpapproved |