Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D07-0032
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/24/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/28/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | September 26, 2007 To: Victor Bolduc Paragon Architects Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ___________________________ From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County Departments of Wastewater Management and Environment Quality Subject: ANEWCO Dev. Plan – 2nd Submittal D07-032 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Obtain a letter from the PCWMD's Development Services Section, written within the past 90 days, stating that treatment and conveyance system capacity for the project is available in the downstream public sewerage system and provide a copy of that letter to this office. The required form to request such a letter may be found at: http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf. The development plan for this project cannot be approved until a copy of this letter has been received by this office. This is the 2nd request. Sheet 2: Change the callout for connection to read as follows: 75 LF 6” PRIVATE BCS CONNECT TO EXISTING 6” STUBOUT (1% SLOPE) AT PROPERTY LINE. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the third(3rd) submittal. A check for the review fee of this submittal in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of blue lines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above-mentioned comments, please contact me. |
| 10/08/2007 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Denied | DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D07-0032 Anewco (X) Tentative Plat () Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: Annexation C9-8595 NEIGHBORHOOD PLAN: General Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: 10/22/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies (X) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (X) Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan (X) Other - Memorandum dated July 6, 1987 REVIEWER: drcorral 791-4505 DATE: 10/05/07 Department of Urban Planning and Design Annexation #C9-85-95, Ordinance established annexation conditions for this case, specifically as follows: A. Ordinance No. 6330 Section 5, zoning classification I-1® conditions: 2. Construction of a wall along the south and west corner of the property extended to Palm Street to be painted earth tones. Please provide a copy of the memorandum dated July 6, 1987 addressing the above condition, confirming this requirement is not applicable to this site. DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D07-0032 Anewco 08/15/07 (X) Tentative Plat () Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: Annexation C9-8595 NEIGHBORHOOD PLAN: General Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: 8/17/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies (X) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (X) Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan (X) Other - Memorandum dated July 6, 1987 REVIEWER: drcorral 791-4505 DATE: 8/15/07 Department of Urban Planning and Design Annexation #C9-85-95, Ordinance established annexation conditions for this case, specifically as follows: B. Ordinance No. 6330 Section 5, zoning classification I-1® conditions: 3. Construction of a wall along the south and west corner of the property extended to Palm Street to be painted earth tones. Item #3, under City of Tucson Annexation Conditions, General Notes section of the development plan, states "Additional memorandums were generated by Mayor and Council that specifically address condition 2 of Section 5 under Ordinance No. 6503. 1. Memorandum dated July 6, 1987; A. After field surveying the subject site (eastside Research/Commerce Center), City staff considers the wall unnecessary along the south property line to the distance between the existing mobile home park (Tucson Meadows) and the building of the Cienega property (Eastside Research/Commerce Center." Please provide a copy of the memorandum dated July 6, 1987 for review. |
| 10/09/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D07-0032 ANEWCO Development Plan Resubmittal TRANSMITTAL DATE: October 8, 2007 DUE DATE: October 22, 2007 COMMENTS: The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 1. Please add the contour interval with the north arrow on sheet 2. DS 2-05.2.1.H 2. Please revise detail DP1/7 placing truncated domes in the direction of travel into the access aisle as warning that an individual is leaving the pedestrian path and entering the vehicle use area. Revise detail DP1/8 by removing truncated domes from in front of motor vehicle parking spaces to prevent sight impaired individuals from being directed into wheel-stop curbing. If you have any questions about this transmittal, please call Karol Aragonez, (520) 837-4960. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D07-0032dpr.doc |
| 10/10/2007 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Approved | |
| 10/12/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 10/25/2007 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | October 25, 2007 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: ANEWCO Development Plan D07-0032 (Second Review) T14S, R15E, Section 21 RESUBMITTAL REQUIRED: None The development plan has been reviewed by the Engineering Division and we recommend approval at this time. The drainage report from Greg Carlson Engineering dated September 20, 2007 is accepted for Development Plan purposes. If you have any questions, I can be reached at 520.837.4927 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |
| 10/26/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES October 26, 2007 Paragon Architects, LLC 2210 East Fort Lowell Road, Suite 100 Tucson, Arizona 85719-2461 Subject: D07-0032 ANEWCO Development Plan Dear Consultant: Your submittal of September 24, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 4 Copies Revised Development Plan (Wastewater, Zoning, DUPD, DSD) 3 Copies Revised Landscape Plan (Zoning, Landscape, DSD) 2 Copies City Memorandum dated July 6, 1987 (DUPD, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 382-0075 dp-resubmittal |