Permit Review Detail
Review Status: Completed
Review Details: REVISION - DEV PLAN
Permit Number - D07-0027
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/04/2010 | RONALD BROWN | ADA | REVIEW | Passed | Not a COT owned/operated property |
| 01/05/2010 | RONALD BROWN | ZONING HC | REVIEW | Denied | 1. As per IBC SECTION 1104 - ACCESSIBLE ROUTE 1104.1 Site arrival points. Accessible routes within the site shall be provided from public transportation stops; accessible parking; accessible passenger loading zones; and public streets or sidewalks to the accessible building entrance served. Exception: Other than in buildings or facilities containing or serving Type B units, an accessible route shall not be required between site arrival points and the building or facility entrance if the only means of access between them is a vehicular way not providing for pedestrian access. 1104.2 Within a site. At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements and accessible spaces that are on the same site. Exception: An accessible route is not required between accessible buildings, accessible facilities, accessible elements and accessible spaces that have, as the only means of access between them, a vehicular way not providing for pedestrian access. a. Please provide an accessible route connecting the East side to the West side. 2. As per IBC Section 106.5 - DEFINED TERM, MARKED CROSSING: A crosswalk or other "identified path" intended for pedestrian use in crossing a vehicular way. a. Please identify the two vehicle crossings on the East side of the building between the detectable warning stips. 3. OK 4. OK 5. OK 6. OK END OF REVIEW |
| 01/07/2010 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approv-Cond | To: Patricia Gehlen DATE: January 7, 2010 CDRC/Zoning Manager SUBJECT: Lot 25, 8272 S. Camino De Café, Parking lot addition. Development Plan D07-0027 (Revision) T15S, R15E, Section 27 RESUBMITTAL REQUIRED: None (Conditional Approval). Development Plan: 1. The STR description in the title block shall read "Section 27, Township 15 South, Range 15 East, G&SRB&M, Pima County, Arizona", not Tucson, Arizona. 2. Verify the vertical datum is in NGVD29 in general note no. 11. Most City of Tucson projects, the vertical datum is in NAVD88. If the NGVD29 datum cannot be verified, than replace the datum with "(Per COT FB)". Drainage Statement: 1. The DS has been accepted by engineering. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Thank You, Paul P. Machado Senior Engineering Associate City of Tucson/Planning and Development Services Department 201 N. Stone Avenue Ave. P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/8272 S. Camino De Cafe CDRC 2 |
| 01/07/2010 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | The loading area screen wall should terminate at least 2' from the edge of the driveway. DS 3-05.2.2.B.3 |
| 01/08/2010 | TERRY STEVENS | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: D07-0027 Lot 25 Brown/Rita Ranch Development Plan - Revision TRANSMITTAL: 01/08/2010 DUE DATE: 01/08/10 COMMENTS: 1. The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\developmentplan\D07-0027dp-rev-a.doc |
| 01/11/2010 | PGEHLEN1 | ENV SVCS | REVIEW | Approved | Declined; Based on Environmental Services, New Solid Waste Disposal Development Standard No.6-01.0. All Developments must show a detail plan of the refuse and recycle container enclosure. The location of the enclosure must be clearly show and labeled at there proposed location on all effected plans to verify collection vehicle accessibility. |
| 01/11/2010 | PGEHLEN1 | ENV SVCS | REVIEW | Approved | Dates Case Number Project Address Issued by DSD 12/24/2009 D07-0027 Lot 25, Brown / Rita Ranch (BK 54 PG 84) Due Date January 8, 2010 Date Received at Pioneer February 2, 2010 Date Reviewed and Comments submitted to DSD: February 3, 2010 Comments: Approved By Environmental Services Department, February 3, 2010 |
| 02/05/2010 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES January 11, 2010 Jeffrey A. Stanley Stanley Engineering & Drainage PO Box 1888 Tucson, Arizona 85702 Subject: D07-0027 Lot 25 Brown/Rita Ranch Development Plan Dear Jeff: Your submittal of November 5, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 5 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 5 Copies Revised Development Plan (HC Site, Engineering, Landscape, Env Svcs, PDSD) 3 Copies Revised Landscape Plan (Engineering, Landscape, PDSD) Should you have any questions, please call me at 837-4919. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 792-0318 |
| 02/05/2010 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES ***REVISED*** February 5, 2010 Jeffrey A. Stanley Stanley Engineering & Drainage PO Box 1888 Tucson, Arizona 85702 Subject: D07-0027 Lot 25 Brown/Rita Ranch Revised Development Plan Dear Jeff: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line, please submit the following documents for sign-off. 1 Rolled blue line COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. The extra rolled blue line set that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. The printing company will deliver the original rolled blue line to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 792-0318 dpapproved |
| 12/23/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/24/2009 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved |