Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D07-0027
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/10/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/17/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | October 16, 2007 To: Jeff Stanley Stanley Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ___________________________ From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County Departments of Wastewater Management and Environment Quality Subject: Lot 25 Brown/Rita Ranch Dev. Plan - 2nd Submittal D07-027 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. 1. Obtain a letter from the PCWMD's Development Services Section, written within the past 90 days, stating that treatment and conveyance system capacity for the project is available in the downstream public sewerage system and provide a copy of that letter to this office. The required form to request such a letter may be found at: http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf. The development plan for this project cannot be approved until a copy of this letter has been received by this office. This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the third(3rd) submittal. A check for the review fee of this submittal in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above-mentioned comments, please contact me. |
| 10/22/2007 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 10/25/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | Submit any revised plans for an additional review. |
| 11/01/2007 | TERRY STEVENS | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: D07-0027 Lot 25 Brown/Rita Ranch Development Plan TRANSMITTAL: 11/01/07 DUE DATE: 11/07/07 COMMENTS: 1. The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 C:\planning\cdrc\developmentplan\D07-0027dpa.doc |
| 11/02/2007 | FRODRIG2 | UTILITIES | TUCSON ELECTRIC POWER | Denied | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR# 184035 November 1, 2007 Stanley Engineering & Drainage, Inc. Attn: Jeff Stanley P.O. Box 1888 Tucson, Arizona 85702 Dear Jeff Stanley: SUBJECT: LOT 25 BROWN/ RITA RANCH - Resubmittal D07-0027 Tucson Electric Power Company (TEP) has reviewed the plan submitted October 25, 2007. TEP is unable to approve the plan at this time. There are existing electrical facilities within the boundaries of this project. In order for TEP to approve the plan the facilities and easements must be depicted on the plans and you must identify all existing UGE routes on the plan. Enclosed is a copy of a TEP facility map showing the approximate location of the existing facilities. All costs associated with the relocation of the facilities in conflict will be billable to the developer. Please resubmit two revised bluelines to City of Tucson or TEP’s review. You may contact the area Designer, Steve Garcia at 917-8739 should you have any technical questions. Sincerely, Henrietta Noriega Office Specialist hn Enclosure cc: P. Gehlen and F. Rodriguez, City of Tucson (by e-mail) S. Garcia, Tucson Electric Power |
| 11/13/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 11/14/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 14, 2007 Jeff Stanley Stanley Engineering & Drainage, Inc. P.O. Box 1888 Tucson, Arizona 85702 Subject: D07-0027 Lot 25 Brown/Rita Ranch Development Plan Dear Jeff: Your submittal of October 10, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Development Plan (Wastewater, TEP, DSD) Should you have any questions, please call me at 837-4919 Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 792-0318 dp-resubmittal |
| 11/14/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | ES approves as submitted. |