Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D07-0024
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/08/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/09/2008 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 07/18/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Almond Plaza D07-0024 Development Plan (3rd Review) TRANSMITTAL DATE: July 18, 2008 DUE DATE: August 5, 2008 COMMENTS: Please resubmit revised drawings along a separate response letter for zoning, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is June 05, 2009. 2. D.S. 2-05.2.4.P The Handicapped sign mounting height is not correct. The bottom of the main sign should be at 7'-0" above finish grade. 3. If the floating façade, items that appear to be columns, intersect with the sidewalk where shown, it appears to encroach into the required landing at the top of the handicapped access ramp, see ICC/ANSI A117.1-2003 Section 406.7. 4. If the floating façade, items that appear to be columns, intersect with the sidewalk where shown, it appears that they reduce the sidewalk width to below the minimum four (4) foot width near the southeast corner of lease area 3. 5. Ensure that all changes to the site plan are reflected on the landscape & grading plan. 6. Additional comments may be forth coming depending on how each comment has been addressed. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\cdrc\developmentplan\D07-0024dp-3rd.doc |
| 07/18/2008 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | July 16, 2008 To: Kevin Hall Design Construction Consultants Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department _____________________________ From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County Departments of Wastewater Management and Environment Quality Subject: Almond Plaza at the Northeast Corner of Country Club and Aviation Hwy Dev. Plan – 3rd Submittal D07-024 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan as submitted. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above-mentioned comments, please contact me. |
| 08/04/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 4 August 2008 D07-0024/Almond Plaza Reviewed by: Ron Brown ACCESSIBLE REVIEW As per 2006 IBC/ICC 117.1 REVIEW OF PREVIOUS COMMENTS BY STEVE SHIELDS, ZONING LEAD PLANNER: Item 3: At the new accessible parking sign detail 4/C1.2, bottom of larger sign to be at 7'-0" as per DOT standards and provide a "VAN ACCESSIBLE" sign just below the main sign. Item 8: Detectable Warnings (Truncated domes) are still shown on Development Plan and detail 10/C1.2. They are not required by ANSI but may be retained as per Owner option. ADDITIONAL COMMENTS: 1. At Detail 10/C1.2: Relocate parking signs just behind 6" curb in the planter. Current location shown could be covered up by landscaping. |
| 08/05/2008 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approv-Cond | DATE: August 5, 2008 TO: Patricia Gehlen; CDRC Manager SUBJECT: Almond Plaza Development Plan Engineering Resubmittal Review REVIEWER: Elizabeth Eberbach LOCATION: COUNTRY CLUB PARK PTN SLY 451.93' LOT 1 BLK 1 ACTIVITY NUMBER: D07-0024 SUMMARY: The revised Development Plan package including the revised Development Plan, Drainage Report, Landscape documents, and response letter were received by Development Services Department Engineering. Development Services Department Engineering has reviewed the received items and recommends conditional approval of the Development Plan. The Drainage Report was reviewed and accepted for development plan purposes only. DEVELOPMENT PLAN COMMENTS: 1) City of Tucson Development Standards (DS) Section No.10-02.2.3.1.6.A.4.a: Label the following items on the Development Plan sheet C1.1: a) Label bleed pipe, outlet, and pump. b) Label existing Q100 with the developed condition Q100 entering and exiting the project boundary. c) Label the maintenance access to basin. 2) DS Sec.10-02.2.3.1.6.A.4.b: On landscape planview, label the maintenance access to basin. If you have questions, call me at 837-4934. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services Department |
| 08/06/2008 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 JENNIFER STEPHENS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: JENNIFER STEPHENS, ADDRESSING OFFICIAL SUBJECT: D07-0024 ALMOND PLAZA/REVISED DEVELOPMENT PLAN DATE: 8/5/08 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Per comment letter dated 3/27/08: Delete Suites 1-4 on sheet 1. Suite numbers will be assigned per PC policy upon request for Tenant Improvements. |
| 08/08/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 8, 2008 Danny X Quihuis Architectural Design Group 2510 East Grant Road, Suite 140 Tucson, Arizona 85716 Subject: D07-0024 Almond Plaza Development Plan Dear Danny: Your submittal of July 8, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 4 Copies Revised Development Plan (ADA, Addressing, Zoning, DSD) 2 Copies Revised Landscape Plan (Zoning, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 323-3337 dp-resubmittal |