Permit Review Detail
Review Status: Completed
Review Details: CORE REVIEW
Permit Number - D07-0023
Review Name: CORE REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/08/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 02/11/2008 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 02/28/2008 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | February 27, 2008 To: Matthew Hamilton, The Built Environment Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ____________________________________ From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: Cutting Edge Fabrication Brown/Rita Ranch - Lots 1 & 2 Development Plan – Rev 1st Submittal D07-0023 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Add a General Note that states: THE ON-SITE SANITARY SEWERS WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS, AND IN ACCORDANCE WITH AN APPROVED OPERATION AND MAINTENANCE PLAN, IF REQUIRED. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me . |
| 03/03/2008 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 03/06/2008 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Revise the landscape plans to provide a 6' high screen for the storage yard. Lleucophyllum candidum usually only grows to 4 feet, Lleucophyllum frutescens is recommended. Revise the vegetative screening note on sheet L1. 2) Revise the plans to provide a barrier at the perimeter of the paved vehicular use area. DS 3-05.2.3.C If vehicular traffic is proposed for the storage area, the paved vehicular use area should be extended. 3) I notice that Cassia artemisioides is proposed sight visibility triangles in several locations. Revise the plans to locate these plants outside of the SVT's. LUC 3.7.2.8 RESUBMITTAL OF ALL PLANS IS REQUIRED |
| 03/10/2008 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: D07-0023 CUTTING EDGE FABRICATION/CORE REVIEW DATE: 3/06/08 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. ES |
| 03/10/2008 | ROGER HOWLETT | COT NON-DSD | URBAN PLANNING & DESIGN | Approved | REVISED DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D07-0023 Cutting Edge Fabrication (XXXX) Tentative Plat () Development Plan (XXXX) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-84-84 NEIGHBORHOOD PLAN: Esmond Station GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 03/10/2008 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment (XXXX) Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: drcorral 791-4505 DATE: 03/04/08 |
| 03/12/2008 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#182672 March 12, 2008 The Built Environment Attn: Matthew Hamilton 232 W 4th St. Tucson, AZ 85705 Dear Mr. Hamilton : SUBJECT: Cutting Edge Fabrication D07-0023 Tucson Electric Power Company has reviewed and approved the development plan submitted March 3, 2008. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Ms. Mary Boice New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8732 Please call the area Designer Steve Garcia at (520) 917-8739, should you have any questions. Sincerely, Henrietta Noriega Office Specialist Design/Build hn Enclosures cc: City of Tucson (email letter only) S. Garcia, Tucson Electric Power |
| 03/12/2008 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 03/13/2008 | ANDY VERA | ENV SVCS | REVIEW | Approved | ES approves revision as shown. No effect to originally approved plan reagrding onsite refuse/recycle collection and storage. |
| 03/17/2008 | DAVID RIVERA | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: D07-0023 Cutting Edge Fabrication - Lots 1, 2, and 3 Development Plan TRANSMITTAL DATE: March 12, 2008 DUE DATE: March 10, 2008 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is February, 07, 2009. Add the site address of the development on teh cover sheet. 2. The General Manufacturing use falls under the "Industrial Use Group Section 6.3.6" category not Commercial. Please revise the note accordingly. DS 2-05.2.2.B.2 3. Per DS 2-05.2.2.B.7, If the property is subject to annexation requirements, provide the Planning Department's applicable C9-__-__ annexation file number, preferably in the lower right corner of the plan. Also list the conditions of development as a note. The case number has been listed as required. List the conditions of development preferably on the cover sheet. DS 2-05.2.2.B.7 4. Delineate the AEZ - ADC-2 and ADC-3 line on the plan. The line appears to affect a small portion of lot 3. General note 18 should include information that states that lot 3 is affected by the AEZ overlay specifically ADC-2 and ADC-3. Add the requested information to general note 3 and add the ADC-2 and ADC-3 line on the plan. DS 2-05.2.2.B.10 5. Provide copies of the recorded lot combo covenant and the Pima County assessor's parcel combo with the next submittal. DS 2-05.2.4.A 6. Per DS 2-05.2.4.N - On the drawing, show the locations and footprints of all structures. Label the heights and dimensions. The main building and the both covered loading areas must be labeled with the building footprint dimensions. DS 2-05.2.4.N 7. The parking calculation must be revised to include the new storage area. Based on the 38,818 square feet as noted on the plan, and additional 78 parking spaces will be required of which three of the required 78 spaces must be disabled parking spaces. Revise the parking calculation to reflect the additional spaces and disabled parking. The drawing must be revised to depict the location of the additional parking spaces required. DS 2-05.2.4.P 8. As a result of the additional vehicle parking spaces required the number of class one and class two bicycle parking spaces or facilities will increase. Revise the bicycle parking calculation to reflect the number of class one and class two spaces needed. Per DS 2-05.2.4.Q Show, on the drawing, off-street bicycle parking locations, including materials for lighting and paving, type of security, dimensions, specific type of rack and the number of bicycles it supports, and the location and type of directional signage, and distance (50 feet max allowed) from the main entrance to the class two facilities. When adjacent to pedestrian paths, indicate the width of clearance available for the pedestrian area. For specifics, refer to Development Standard 2-09.0. Provide, as a note, calculations on the number of bicycle spaces required and the number provided. 9. Indicate the location, size, height, and type of all existing or proposed freestanding signs, including existing billboards. DS 2-05.2.4.W 10. See landscape reviewer comments related to landscaping and screening requirements. DS 2-05.2.4.X 11. Per an interpretation made by the Zoning Administrator, the surface areas for proposed storage areas may be treated with a minimum of two inches of compacted gravel. If this is the case for this development a note is to be added to the plan stating that the storage areas as defined on the plan will only be accessed by forklift vehicles. Add an additional keynote for the surface treatment. If materials other than gravel are proposed indicate the material type. Approval for materials not listed in the LUC may or will require approval by the Zoning Administrator. If vehicles other than forklifts will be accessing the storage area the vehicular use must be paved per LUC section 3.3.73 surfacing requirements. Additional comments may be forthcoming on this issue based on revised plans. If the storage is not to be accessed by vehicles other than forklifts provide barriers to keep vehicles off the storage area. Draw and label the type of barrier proposed i.e., extruded curbing, fence etc. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. DGR C:\planning\cdrc\developmentplan\D070023dp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, and additional requested documents. |
| 03/19/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES March 19, 2008 Matthew Hamilton The Built Environment 232 West 4th Street Tucson, Arizona 85705 Subject: D07-0023 Cutting Edge Fabrication Revised Development Plan Dear Matthew: Your submittal of February 8, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Development Plan (Landscape, Zoning, DSD) 3 Copies Revised Landscape Plan (Landscape, Zoning, DSD) 2 Copies Lot Combo Covenant (Zoning, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 624-3867 |