Permit Number: D07-0016
Parcel: 12417229A

Address: Unknown

Review Status: Completed

Review Details: DEVELOPMENT PLAN

Permit Number - D07-0016
Review Name: DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/17/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/20/2007 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
D07-0016
SOUTHWESTERN CONSULTING ENGINEERS
M&B MECHANICAL

--------------------------------------------------------


Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
04/24/2007 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: April 24, 2007

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov

CC: Patricia Gehlen


SUBJECT: D07-0016 M&B Mechanical: Development Plan Review(4-17-07)

Parks and Recreation has no comments.
04/25/2007 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#180493 April 25, 2007

Southwestern Consulting Engineers
Attn: Steve Wollerman
435 E 9th Street
Tucson, Arizona 85705

Dear Mr. Wollerman :

SUBJECT: M & B Mechanical
D07-0016

Tucson Electric Power Company has reviewed and approved the development plan submitted April 17, 2007. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. TEP will need a full set of approved site, electrical load, paving off-site improvements and irrigation plans.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Ms. Mary Boice
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8732

Please call the area Designer Mike Kaiser at (520) 918-8244, should you have any questions.

Sincerely,


Elizabeth Miranda
Office Support Specialist
Design/Build
lm
Enclosures
cc: P. Gehlen and F. Rodriguez, City of Tucson (email)
M. Kaiser, Tucson Electric Power
05/01/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
05/02/2007 TIM ROWE PIMA COUNTY WASTEWATER Denied April 30, 2007

To: Steve Wollerman, Southwestern Consulting Engineers

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

____________________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: M & B Mechanical
Development Plan – 1st Submittal
D07-0016

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

Obtain a letter from the PCWMD's Development Services Section, written within the past 90 days, stating that treatment and conveyance system capacity for the project is available in the downstream public sewerage system and provide a copy of that letter to this office. The required form to request such a letter may be found at:

http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf.

The development plan for this project cannot be approved until a copy of this letter has been received by this office.


All Sheets: Add the case number, D07-0016, to the title block of each sheet. This number should be shown larger or bolder than any cross reference numbers. No wastewater review fees will be charged for sheets where this is the only required revision.

Sheet 1& 2: Show the public and private sewer lines using different line-types, so that they can readily be distinguished from each other. Also show and describe examples of these different line types in the legend on Sheet 1. Also the line types between existing and proposed should be readily distinguishable.

Sheet 1: Add a General Note that states:

THIS PROJECT WILL HAVE ______ EXISTING AND______ PROPOSED WASTEWATER FIXTURE UNIT EQUIVALENTS PER TABLE 13.20.045(E)(1) IN PIMA COUNTY CODE 13.20.045(E).

And fill in the blanks with the appropriate values.


Sheet 2: The IMS #’s for all existing manholes need to be shown on plan. Also the rim and invert elevations need to be shown and the existing sewer line/manholes need to be marked as public. Some of the information for the existing sewer G-137 appears to be inaccurate. For instance the sewer line west of the project on Santa Rita is an 8” pipe w/ slope of 0.5%. Revise the existing public sewer information as required.

Sheet 2: In some cases the sewer segment length/slope are not clear as to what sewer segment is being referred to, please revise.

Sheet 2: When calling out the existing sewer state PER PLAN G-137.

Sheet 2: Show the rim and invert elevations for proposed cleanout and it is unclear per the plan if the HCS exists or is proposed, please clarify. Also the BCS from cleanout to building should be a minimum of 2% slope and show the directional flow arrows.

Sheet 2: A Joint Use and Maintenance Agreement, between the proposed (5)new buildings will need to be recorded for the shared private sewer line, before this office will be able to approve this development plan. Prior to signature or recordation, this agreement must be reviewed and approved by Ms. Ilene Deckard of the PCWMD Development Services Section. Also, this property may need to grant a private sewer easement over the shared sewer line. Please contact Ms. Deckard about this matter as soon as possible. She can be reached at 740-6544.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $200(made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.

If you have any questions regarding the above mentioned comments, please contact me .
05/02/2007 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: D07-0016
M&B Mechanical
Development Plan

TRANSMITTAL DATE: May 2, 2007

DUE DATE: May 15, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

Per rezoning case C9-05-09 the applicant proposed to locate a single building housing a heating and cooling warehouse with proposed zoning designation C-3. The development plan submitted indicates the proposed principal use as General Manufacturing showing five (5) individual suites occupying the site.

Warehouse or "Commercial Storage" requires parking as follows:
One (1) space per five thousand (5,000) sq. ft. GFA plus one (1) space per five thousand (5,000) sq. ft. of outdoor storage area for the first twenty thousand (20,000) sq. ft. of outdoor storage area plus one (1) space per ten thousand (10,000) sq. ft. of outdoor storage area over twenty thousand (20,000) sq. ft. of outdoor storage area.

General Manufacturing requires parking as follows:
One (1) space per five hundred (500) sq. ft. GFA.

For this site Commercial Storage would require two (2) motor vehicle parking spaces while General Manufacturing would require seventeen (17) motor vehicle parking spaces

This constitutes a change of use and requires the applicant to go back to the Mayor and Council to request such a change.

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960.

KAA S:\zoning review\karol\planning\cdrc\developmentplan\D07-0016dp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents.
05/07/2007 FRODRIG2 OTHER AGENCIES PIMA ASSN OF GOVTS Approved CASE: D07-0016 M&B MECHANICAL: DEVEL PLAN

COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS



Please call if you have questions or need additional information.





Tom Cooney, Travel Forecasting Manager

Pima Association of Governments

177 N. Church Ave, #405

Tucson, AZ 85701

Tel: (520) 792-1093, Fax: (520) 620-6981

Web: www.PAGnet.org and www.RTAmobility.com
05/07/2007 JIM EGAN COT NON-DSD FIRE Approved
05/10/2007 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Add the CDRC case number to the landscape and native plant preservation plans. DS 2-07.2.1.B

2) Dimension the length and width of landscape borders on the landscape plan per DS 2-07.2.2.A.2.f.
The dumpster storage and loading & parking areas along Mountain Ave. may not be located in the 10' wide border.

3) Revise the plans to provide a 6' high screen wall for the loading area. LUC Table 3.7.2-I

4) Grading, hydrology, and landscape structural plans are to be integrated to make maximum use of site
storm water runoff for supplemental on-site irrigation purposes. The landscape plan shall indicate use of
all runoff, from individual catch basins around single trees to basins accepting flow from an entire vehicular use area or roof area. Identify water harvesting areas on the landscape plan. LUC 3.7.4.3.B

5) A vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from extending beyond the property lines; damaging adjacent landscaping, walls, or buildings and to prevent vehicles from driving onto unimproved portions of the site.
per DS 3-05.2.3.C. Revise the plans as necessary to specify curbs for all planting areas.

6) The screening along Twenty-first is required to be continuous. Revise as necessary. LUC Table 3.7.2-I.

7) Any required storm water detention/retention basins shall be landscaped to enhance the natural configuration of the basin. Design criteria are set forth in Development Standard 10-01.0. LUC 3.7.4.3.A

8) The area between the right-of-way line and sidewalk and the area between the sidewalk and the curb, if not covered with vegetation, shall be covered with an appropriate inorganic ground cover, such as decomposed granite. Revise the plans to clarify compliance. LUC 3.7.2.4.A.4

9) Revise the plans to clarify compliance with rezoning conditions 11 and 13. C9-05-09

10) Submit photos as required in rezoning condition 5 and revise the plans as necessary to comply with condition 2.

11) The Native Plant Preservation application is under review. Plants on the site have been removed and the submitted photos are not sufficient to document site vegetation. The inspection from Arapahoe Tree Service does not adequately describe site vegetation or the appropriate preservation standard. Protected Native Plants designated in Sec. 3.8.5 shall not be destroyed, damaged, salvaged, transplanted, or removed from the site except in accordance with the approved Plan. LUC 3.8.4.2

12) Revise the landscape plan to identify the mesquite species proposed. DS 2-07.2.2.A


RESUBMITTAL OF ALL PLANS IS REQUIRED. THE NATIVE PLANT APPLICATION IS UNDER INVESTIGATION.
05/16/2007 ED ABRIGO PIMA COUNTY ASSESSOR Passed
05/16/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D07-0016 M&B Mechanical

() Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-89-05-09

NEIGHBORHOOD PLAN: Greater South Park

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 05/15/07

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies with Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(XXXX) Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
(XXXX) Other – Sign Details

REVIEWER: drcorral 791-4505 DATE: 05/15/07

Rezoning condition #8 states “free standing signs to be integrated into the overall landscape plan. Details of signs are to be submitted as part of the development plan. Please submit details of signs integrated into the landscape plan to satisfy this requirement.

2. Add case number D07-0016 to development plan, elevation and landscape sheets.
05/16/2007 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed
05/17/2007 ANDY VERA ENV SVCS REVIEW Denied 1. DP shheet 2 - The 14ft x 40ft clear approach nor the 3ft buffer is not provided. DS 6-01.4.1.C and figure 1, turning radii.
Recommend postioning enclosure further back to allow for required clear approach or angle at 30 degrees and ensure parking spaces do not encroach.

2. Trash enclosure detail on sheet 3:
A. Require a 10ft inside clear between the side wall protector and between the rear wall protectors and the front gates. DS 6-01.4.1.B. Measurement needs to be from the face of the wall protectors not center to center.

B. Recommend constructing gates so they open a minimum of 180 degrees. This will allow for the 14ft x 40ft clear approach to be measured from the face and/or entrance of the enclosure and ensure clearance for backing.

Make all necessary changes for resubmittal.
05/17/2007 FRODRIG2 COT NON-DSD REAL ESTATE Approv-Cond >>> Jim Stoyanoff 05/16/2007 3:18 PM >>>
No comments from Real Estate, but it appears that the pavement on Mountain Avenue is substandard (about 20' of pavement) and allowing two way traffic from the parking lot on to Mountain may cause safety concerns.
06/04/2007 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D07-0016 M & B MECHANICAL/DEVELOPMENT PLAN
DATE: 5/10/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE: Approved with the following conditions:

Correct Twenty-First Street to 21st Street on mylar.

2.) Spell out “Avenue” for Santa Rita and Mountain on mylar.

Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.



es
06/12/2007 JASON GREEN ENGINEERING REVIEW Denied DATE: June 12, 2006
SUBJECT: M&B Mechanical Development Plan- Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 1101 S Santa Rita Ave, T14S R14E Sec18, Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: D07-0016


SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed development plan and Drainage Statement (Southwestern Consulting Engineers, LLC, 04APR07). Engineering does not recommend approval of the development plan at this time. The drainage report was reviewed for development plan purposes only. The following items need to be addressed:

DEVELOPMENT PLAN: Any changes to the development plan due to Zoning Comments may cause additional engineering comments to be generated at the next resubmittal.

1) DS Sec.2-05.2.1.C: Verify that 12-point font is used throughout the development plan. Specifically within the Vicinity Map located on Sheet 1.

2) DS Sec.2-05.2.1.K: The correct development plan number (D07-0006) may be added to the lower right hand corner of the plan on all sheets.

3) DS Sec.2-05.2.2.A.1: Provide the telephone number for the Owner/Developer that is shown on Sheet 1.

4) DS Sec.2-05.2.3.B: Verify that all easements are shown on the development plan.

5) DS Sec.2-05.2.3.C: Provide the right-of-way (r-o-w) recordation information for Santa Rita Ave, Mountain Ave, and 21st Street. Label and dimension the r-o-w width for both Mountain Ave and 21st Street on the development plan.

6) DS Sec.2-05.2.4.D.3: Label and dimension all points of egress and ingress for the subject parcel. Refer to the Transportation Access Management Guidelines for the minimum driveway width requirements.

7) DS Sec.2-05.2.4.H.2: Review and approval from TDOT Permits and Codes for all proposed improvements within the public right-of-way will be required. A right-of-way use permit application will be required prior to construction. Contact Steve Tineo at 741-3115 for all right-of-way requirements and permit applications.

8) DS Sec.2-05.2.4.H.3: The scuppers proposed under the sidewalk must be designed and constructed to convey the 10-year flood flow. Provide a revised drainage statement showing scupper calculations and design that demonstrate that the 10-year flood flow is contained under the sidewalk.

9) DS Sec.11-01.9: Revise the grading plan to provide cross sections at all property boundaries to verify that the required 2-feet setback from property lines to the proposed limits of grading and proposed water harvesting area fill slopes have been met. Provide sufficient room to allow for the 2-feet setback from property lines to top of and toe of fill slopes.

10) DS Sec.11-01.2.1: Provide estimated cut and fill quantities on the development plan for grading plan purposes.

DRAINAGE REPORT:

11) Provide a discussion within the revised drainage statement that addresses localized street flooding. Due to previous drainage complaints and past site inspections of the area it has been noted that the roads act as collector channels for all storm events. Verify that this localized drainage does not effect the subject property and that all flows are contained within the adjacent streets or proposed water harvesting areas.

12) DS Sec. 3-01.4.4.F: Provide a revised drainage report showing scupper calculations that demonstrate that the 10-year flood flow is contained under the sidewalk at all scupper concentration points. Provide details and dimensions in plan view for the scuppers on the proposed development plan.

GRADING PLAN:

13) DS Sec.11-01.2.1: A grading permit may be required for this project depending on the cut and fill quantities provided at resubmittal. If fill quantities exceed 50 cubic yards a grading plan and a grading permit application will be required after development plan approval and prior to any construction activity. A grading permit may not be issued prior to development plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the development plans

14) Please ensure that any future grading plan will be consistent with the development plan and drainage statement. Grading standards may be accessed at: http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf

15) Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans (SWPPP) and text addressing stormwater controls for all areas affected by construction activities related to this development will be required with a grading plan submittal. For further information, visit www.adeq.state.az.us/environ/water/permits/stormwater.html.

16) If fill quantities exceed 50 cubic yards provide a general note on the development plan that references the City of Tucson Development Standard 11-01.0 (excavation and grading requirements).

GENERAL COMMENTS:

Please provide a revised development plan and a revised drainage statement that address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the development plan and drainage statement reviews.

For any questions, or to schedule a meeting call me at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
06/12/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 12, 2007

Steve Wollerman
Southwestern Consulting Engineers
435 East 9th Street
Tucson, Arizona 85705

Subject: D07-0016 M&B Mechanical Development Plan

Dear Steve:

Your submittal of April 17, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

7 Copies Revised Development Plan (Wastewater, Zoning, Landscape, DUPD, ESD, Engineering, DSD)

5 Copies Revised Landscape Plan (Zoning, Landscape, DUPD, Engineering, DSD)

2 Copies Revised NPPO Plan (Landscape, DSD)

2 Copies Revised Drainage Report (Engineering, DSD)

2 Copies Photographs (Landscape, DSD)


Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 628-1063