Permit Number: D07-0013
Parcel: 14111002B

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D07-0013
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/05/2012 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/05/2012 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Passed LETTER IN FILE FROM PIMA COUNTY
03/08/2012 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning & Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: A-Atlas Discount Storage - Revision
D07-0013
Development plan (Revision #2)

TRANSMITTAL DATE: March 8, 2012

DUE DATE: March 20, 2012

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, shown between buildings 8 & 9 presents a safety hazard. Crosswalks should run perpendicular to the parking area access lane (PAAL). As there is an additional pedestrian access/accessible route that connects these buildings to the other buildings on site this crosswalk is not required.

2. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, that runs east from building 7 presents a safety hazard. Crosswalks should run perpendicular to the parking area access lane (PAAL). As there is an additional pedestrian access/accessible route that connects these buildings to the other buildings on site this crosswalk is not required.

3. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, that runs west from building 10 presents a safety hazard. Crosswalks should run perpendicular to the parking area access lane (PAAL). As there is an additional pedestrian access/accessible route that connects these buildings to the other buildings on site this crosswalk is not required.

4. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, that runs south from near the southwest corner of building 10 presents a safety hazard as it is a stripped area within the PAAL. The area of the crosswalk the runs parallel to the PAAL needs to be a sidewalk physically separated from the PAAL.

5. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, that runs south from near the southwest corner of building 6 presents a safety hazard as it is a stripped area within the PAAL. The area of the crosswalk the runs parallel to the PAAL needs to be a sidewalk physically separated from the PAAL.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\cdrc\developmentplan\D07-0013Rdp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan.
03/13/2012 JWILLIA4 PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 2ND FL
TUCSON, AZ 85701-1207


AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: D07-0013 A-ATLAS DISCOUNT STORAGE/REVISED DEVELOPMENT PLAN
DATE: March 13, 2012



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

On the Final Development Plan delete SW ΒΌ on all title blocks.


1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.
03/14/2012 JWILLIA4 ENV SVCS REVIEW Denied Due Date Case Number Project Address
March 14, 2012 D07-0013 A-ATLAS DISCOUNT STORAGE
Revision Development Plan
Comments: Dined
The proposed Development Plan for the A-ATLAS DISCOUNT STORAGE
Case No. 07-0013, dose not meet the minimum requirements for Environmental
Services, Standers 6.01.

1. Some of the turning radius shown on the development plan are less then required for service truck vehicles. The minimum turning radius required for solid waste
service vehicles are 50ft to the outside and 36ft to the inside, required for
maneuvering and servicing of solid waste containers.

2. All solid waste and recycle enclosure shown on the Development plan must be labeled for their intended use, if for Solid Waste or Recycle Disposal.


Environmental Services Department
Development Plan Review
Reviewer: Tony Teran
Office Phone (520) 837-3706
E-mail: Tony.Teran @tucsonaz.gov
03/15/2012 RONALD BROWN ZONING HC REVIEW Denied SHEET 8
1. Please provide detectable warnings at the westerly ends of both marked crossings located on the east side of buildings 4 and 5.
DETAIL N/C-1.4
2. Please provide retrurn curbs to the top of the landing.
END OF REVIEW
03/19/2012 PAUL MACHADO ENGINEERING REVIEW Denied The project is in denied status until a field visit after the recent rain is done to determine positive flow/ponding at the basin outlet. Results from the field visit will be posted as comments in permits plus on 03-20-12. PM. 03-19-12. Eng. Div.
03/19/2012 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: March 20, 2012
CDRC/Zoning Manager
SUBJECT: A-Atlas Storage - Revision, 8300 E. Valencia Rd.
Dev Plan D07-0013 (First Review - Rev. 2)
T15S, R15E, Section 21

RESUBMITTAL REQUIRED: Development Plan and Drainage Report.

The Development Plan (DP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Development Plan:

1. Please include a detailed response letter to the comments along with the corrected copies of the DP.
2. Provide recording information on the plans for the acquired off-site drainage easement for the basins discharge.
3. Upon a recent field visit to the site it appears that the channel for the outlet for the ret./det. basin appears to be graded to low to drain and will not "daylight". Provide spot elevations on the plans demonstrating positive drainage.
4. It appears that there is drainage flow exiting the property west of and adjacent to the off-site turnaround that should be entering the basin. This shall be corrected by redirecting the water into the ret./det. basin.
5. The off-site turnaround was not built to plan. Show the correct as-built on the new sheets.
6. The sidewalk adjacent to and SE of Bldg. no. 9 requires a scupper to allow the 10-yr. event to flow under the sidewalk.
7. A sidewalk scupper is also needed adjacent to and N. of Bldg. 11.
8. The min. surface material for a paved storage area is double-shot chip seal per Sec. 3.3.7.3 of the LUC.
9. Show a detail of the "Additional rock rip-rap" adjacent to bldg. no. 1
10. The Grading Plan must also be revised to reflect the changes made in the field and shown on the revised DP.

Drainage Report:
1. Please include a response letter to the comments along with the corrected copies of the DR.
2. Upon a recent field visit to the site it appears that the channel for the outlet for the ret./det. basin appears to be graded to low to drain and will not "daylight". Provide spot elevations on the plans demonstrating positive drainage.
3. Addendums to any Drainage Reports and Hydrology Reports etc. are not accecpted. The new layout or revisions must be incorporated into the original approved Drainage Report.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson - Planning and Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/8300 E. Valencia Rd. CDRC Rev. 2
03/20/2012 JOE LINVILLE LANDSCAPE REVIEW Approved
03/20/2012 KBROUIL1 COT NON-DSD FIRE Approved
03/21/2012 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

March 21, 2012

Steve Wollerman
Southwestern Consulting Engineers, LLC
2342 W. Monet Way
Tucson, Arizona 85741

Subject: D07-0013 A-ATLAS DISCOUNT STORAGE Development Plan

Dear Steve:

Your submittal of March 26, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 5 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

5 Copies Revised Development Plan (Zoning, Env Svcs, Zoning HC, Engineering, PDSD)

2 Copies Revised Drainage Report (Engineering, PDSD)


Should you have any questions, please call me at 837-4893.


Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (520) 300-7300