Permit Number: D07-0013
Parcel: 14111002B

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D07-0013
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/30/2010 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
10/01/2010 DAVID MANN COT NON-DSD FIRE Approved
10/07/2010 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
10/12/2010 RONALD BROWN ZONING HC REVIEW Denied The drawing quality submitted for this revision is not suitable for an accessible review. It is confusing, the information appears overlapped and in most cases they are illegible. Please revise all drawings and resubmit in a format that provides the originally approved development plan separate from the revisions. Provide a separate set of drawings showing nothing but the revisions. Delete all "X"s and the design element meant to be deleted.
10/13/2010 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Submit a revised landscape/NPPO plan.

2) Revise the landscape and native plant preservation plans to show the phases represented on the development plan and to indicate that each phase complies with all requirements as a separate entity. Show and label any temporary improvements that may be needed for code compliance or those needed to make the site function for each phase as one entity. DS 2-05.2.4.C
10/14/2010 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: October 14, 2010
CDRC/Zoning Manager

SUBJECT: A-Atlas Storage - Revision, 8300 E. Valencia Rd.
Development Plan D07-0013 (First Review - Rev.)
T15S, R15E, Section 21

RESUBMITTAL REQUIRED: Development Plan - Revision and Drainage Report.

The Development Plan (DP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Development Plan:

1. Please include a detailed response letter to the comments along with the corrected copies of the DP.
2. It appears that the revisions to the DP shown are not drawn on the originally approved DP but are instead shown on a different copy of the DP with the registrants seal and the City of Tucson CDRC office approval stamp photocopied and affixed to the plan. All revisions must be shown on the originally approved stamped DP with the original stamps not copied and affixed.
3. FYI - Per AzTBR Statute 32-125.D: "It is unlawful for any nonregistrant to cause or permit the illegal use of a registrant's seal, signature or stamp on any document prepared by the nonregistrant." Also, per the Page 4 of the Arizona State Board of Technical Registration seal information, March 8, 2008, section F. "Methods of transferring a seal other than an original seal imprint or a computer-generated seal are not acceptable." The url for the referenced statute above is: http://www.btr.state.az.us/UserFiles/File/word%20documents/seal%20web%20page.doc
4. Per a recent field visit to the site an array of grading and construction issues were observed. Some of the issues are but not limited to: The area beyond the outlet for the ret./det. basin appears to be located outside the ret./det. esmt. and graded to low to drain; the off site turnaround is not built per plan; the parking lot for the RV's is not graded per plan , sidewalk scuppers located in high spots instead of low spots, the reconfigured storage areas must have soil protection, not just dirt etc.
5. The plan is difficult to read; perhaps an addition sheet is warranted for the grading information. Address as required.
6. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20.
7. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DP.
8. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Because of the multitude of grading issues, there may be a difference of datum elevations. It is suggested that the bench mark elevation and the contour elevation be rechecked.
9. Per the City of Tucson engineering inspector, Dave Roberts - 837-7643, he has posted his comment on the City of Tucson web page and has also given a copy of the comments to the owner of the project. All field revisions shall be shown on the revised DP.
10. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
11. The previous Stormwater Pollution Prevention Plan (SWPPP's) and the grading plan must be revised also.

Drainage Report:
1. Please include a response letter to the comments along with the corrected copies of the DR.
2. Because of the grading and construction issues mentioned above, the DR will have to be revised also.
3. Address the drainage solution to the ret./det. basin in the DR.
4. If applicable, add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DR.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson - Planning and Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/8300 E. Valencia Rd. CDRC Rev.
10/14/2010 FRODRIG2 ENV SVCS REVIEW Approv-Cond Date October 14, 2010

Due Date Case Number Project Address
October 14, 2010 D07-0013 A-ATLAS DISCOUNT STORAGE
DEVELOPMENT PLAN

Comments: The proposed Development Plan for the A-ATLAS DISCOUNT STORAGE,
Case No. D10-0013, Located at Valencia and Old Vail Road, meets the
minimum requirements for the Environmental Services, Solid Waste Disposal
Standard 6-01.0 and is Approved, with the flowing exceptions.

1. The proposed container enclosures shown on the development plan must be labeled
for their intended use, if for Solid Waste or Recycle materials.

2. In order to establish a route to provide Environmental Services the physical
address must be clearly shown on the Title Block on all sheets of the development
plan.


Environmental Services Department
Development Plan Review
Reviewer: Tony Teran
Office Phone (520) 837-3706
E-mail: Tony.Teran @tucsonaz.gov
10/14/2010 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: A-Atlas Discount Storage - Revision
D07-0013
Development plan (Revision)

TRANSMITTAL DATE: October 14, 2010

DUE DATE: October 14, 2010

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. As there have been numerous changes to this development plan provide a clean plan that clearly shows all changes. Remove any items shown that now are not being used, i.e. "X"ed out. Once a cleaned up development plan has been provided additional comments maybe forth coming.

2. Remove the signed and dated City of Tucson DSD/CDRC Approval stamp from the drawings.

3. D.S. 2-05.2.3.B There is a "NEW 15' PUBLIC WATER EASEMENT" called out under keynote 17 on sheets 2 & 3, provide the recordation information, docket and page, on the plan.

4. D.S. 2-05.2.4.C If the project is to be phased, provide calculations, setbacks, etc., to indicate that each phase complies with all requirements as a separate entity. Show and label any temporary improvements that may be needed to make the site function for
5. each phase as one entity. That said the calculations do not show phasing and it is not clear on the plan if any temporary improvements are proposed or required.

6. D.S. 2-05.2.4.D.3 Provide a PAAL width dimension for the secondary access shown southwest of building #11. If this is a two-way PAAL the minimum width is 24'.

7. D.S. 2-05.2.4.D.4 The area labeled as "PHASE 2", it is not clear what is to be constructed and what isn't, i.e. if areas of pavement are not going to be constructed some type of barrier will be required to prevent vehicles from accessing area that are not developed.

8. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, shown at the northeast corner of building #5 appears to encroach into the 24' PAAL width. Clearly show on the plan how the 24' PAAL width is maintained.

9. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, shown directly east of building #7 is a safety hazard. This crosswalk should run perpendicular to the PAAL.

10. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, shown directly east of building #8 is a safety hazard. This crosswalk should run perpendicular to the PAAL.

11. D.S. 2-05.2.4.K Building #9, southern most corner, there is what appears to be an overhead door shown. Demonstrate on the plan how access to this door is provided across the sidewalk. Vehicle parking spaces may not be used for access to this door.

12. D.S. 2-05.2.4.K Building #10, northwest side of the building, there are two (2) overhead doors shown. Demonstrate on the plan how access to these doors is provided across the sidewalk.

13. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, shown running west from building #10 to the parking area is a safety hazard. This crosswalk should run perpendicular to the PAAL.

14. D.S. 2-05.2.4.K The pedestrian access/accessible route, crosswalk, shown running south from building #10 across the main drive encroaches into the PAAL area going into to storage facility. The crosswalk area running parallel to the PAAL must be sidewalk physically separated from the PAAL.

15. D.S. 2-05.2.4.P The wheel stops shown on Detail AP sheet 6 are not shown correctly. These wheel stops should be shown perpendicular to the long dimension of the parking space.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\cdrc\developmentplan\D07-0013Rdp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan.
10/18/2010 FERNE RODRIGUEZ PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 2ND FL
TUCSON, AZ 85701-1207


JENNIFER STEPHENS
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: JENNIFER STEPHENS, ADDRESSING REVIEW
SUBJECT: D07-0013 A-ATLAS SELF STORAGE REVISION 1/DEVELOPMENT PLAN
DATE: October 18, 2010



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.
10/19/2010 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

October 19, 2010

Steve Wollerman
Southwestern Consulting Engineers, LLC
2342 W. Monet Way
Tucson, Arizona 85741

Subject: D07-0013 A-ATLAS DISCOUNT STORAGE Development Plan

Dear Steve:

Your submittal of March 26, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 6 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Development Plan (Zoning HC, Landscape, Env Svcs, Zoning, Engineering, PDSD)

4 Copies Revised Landscape Plan (Landscape, Zoning, Engineering, PDSD)

2 Copies Revised NPPO Plan (Landscape, PDSD)

2 Copies Revised Drainage Report (Engineering, PDSD)


Should you have any questions, please call me at 837-4917.


Sincerely,




John Williams
Planning Technician