Permit Number: D07-0011
Parcel: 11449027A

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D07-0011
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/23/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/07/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
11/15/2007 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: D07-0011
Tucson Community Church East
Development Plans

TRANSMITTAL: 11/15/07

DUE DATE: 04/24/07

COMMENTS:

1. Zoning acknowledges your response. The SCZ review and approval is required before approval of the development plan can be granted. See comments from SCZ submittal T07SA00225 and include any changes required to the development plan.

2. This comment has not been addressed. DS 2-05.2.4.F Clearly indicate the location of the future curb along the street frontage of Tanque Verde.

3. This comment has not been addressed. DS 2-05.2.4..I Remove the indicated 96' and 49' side setback lines and provide dimensions from the structures to the perimeter property lines and from the future curb.

4. DS 2-05.2.4.P Clarify the parking calculations provided. The parking calculations in note #11 indicates required parking per 4950 sq. ft., the detail of the assembly area indicates 1200 sq. ft., clarify. The required parking is based only on the GFA of the assembly area.

Revise the total number of required parking spaces in note #11.

5. DS 2-05.2.4.Q This comment has not been addressed. Provide a detail of the one (1) required class one type locker clearly indicting the height of the locker.

6. Provide in note #11 the allowed and proposed lot coverage calculations.

7. Depending on changes to the plan and responses to the above comments further comments may be forth coming.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

TLS C:\planning\cdrc\developmentplan\D07-0011-2dp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan
11/28/2007 PAUL MACHADO ENGINEERING REVIEW Approved
11/30/2007 ANDY VERA ENV SVCS REVIEW Approved
12/03/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 3, 2007

Steve Wollerman
Southwestern Consulting Engineers
435 East 9th Street
Tucson, Arizona 85705

Subject: D07-0011 Tucson Community Church Development Plan

Dear Steve:

Your submittal of October 23, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Development Plan (Zoning, DSD)

2 Copies Revised Landscape Plan (Zoning, DSD)




Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 628-1063
dp-resubmittal