Permit Number: D07-0008
Parcel: 14122004G

Address:
8500 S RITA RD

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D07-0008
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/10/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/14/2008 JIM EGAN COT NON-DSD FIRE Denied The minimum pavement section for a fire lane is 2 inches of AC on 4 inches of ABC. See the Transportation Development Standards.
07/17/2008 PAUL MACHADO ENGINEERING REVIEW Approv-Cond To: Patricia Gehlen DATE: July 17, 2008
CDRC/Zoning Manager

SUBJECT: Global Solar Energy, 8500 S. Rita Ranch Road
Development Plan D07-0008 Revision (Second Review)
T15S, R15E, Section 28

RESUBMITTAL REQUIRED: None.

Development Plan:

1. The Development plan has been conditionally approved. Revise the plan to reflect the following changes on the Mylar submittal.
2. Ensure both the ingress/egress a min. 20' in width using median.
3. Show the future sight visibility triangles at Rita Rd.

Drainage Statement:
1. The DS is accepted by engineering.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@ci.tucsonaz.govs
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax,
C:/8500 S. Rita Ranch Rd CDRC_REV_3
07/17/2008 TERRY STEVENS ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: D07-0008
Global Solar Energy
Development Plan --Revision

TRANSMITTAL: 07/17/2008

DUE DATE: 08/07/09

COMMENTS:


1. The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961


C:\planning\cdrc\developmentplan\D07-0008dpa.doc
07/22/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 22, 2008

Richard Corodova
DOWL Engineers
166 W Alameda
Tucson, Arizona 85701

Subject: D07-0008 Global Solar Energy Facility Revised Development Plan

Dear Richard:

Your submittal of July 10, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

3 Copies Revised Development Plan (Fire, Landscape DSD)

2 Copies Revised Landscape Plan (Landscape, DSD)

2 Copies Revised NPPO (Landscape, DSD)




Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 624-0384
dp-resubmittal
07/25/2008 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond The following comments apply to this submittal:

1) Submit a revised Native Plant Preservation Plan.

2) Revise the Landscape Plan to match the revisions made to the Development Plan.

3) Revise the Landscape and Native Plant Preservation plans to include a limit of disturbance/grading. Show protective fence locations for PIP plants and undisturbed or natural areas.

THESE COMMENTS HAVE BEEN ADDRESSED BY THE LA ON PLANS DATED 07/24/08. SUBMIT MYLARS OF THE CORRECTED PLANS WITH THE DEVELOPMENT PLANS.