Permit Number: D07-0008
Parcel: 14122004G

Address:
8500 S RITA RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D07-0008
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/26/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/04/2007 PAUL MACHADO ENGINEERING REVIEW Approved
05/10/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond May 10, 2007

To: Richard Cordova
DOWL Engineers

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

____________________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Global Solar Energy New Facility
Development Plan – 2nd Submittal
D07-008

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


All Sheets: Add the case number, D07-0015, to the title block of each sheet. This number should be shown larger or bolder than any cross reference numbers. No wastewater review fees will be charged for sheets where this is the only required revision. The case number was added but needs to be bigger and bolder.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above mentioned comments, please contact me .
05/14/2007 JIM EGAN COT NON-DSD FIRE Denied On the new igress easement, "NO PARKING FIRE LANE" signs shall be provided as needed to provide 20' clear unobstructed width along all fire apparatus access roadways in accordance with the fire code.
05/16/2007 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: D07-0008
Global Solar Energy
Development Plan Resubmittal

TRANSMITTAL DATE: May 3, 2007

DUE DATE: May 24, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please provide a copy of the lot split approved by City of Tucson. Add the lot split case number and date of approval in the lower right corner of the development plan.

2. Please provide a detail of Class 2 bicycle parking. Multiple rack bicycle parking require a minimum thirty (30 inches between outer spaces of posts or racks (DS 2-09.5.1.A). The rack must provide two-point support for bicycles. Please review DS 2-09.8.0 Figure 2 - 7 for acceptable and unacceptable rack designs, Figure 8 for rack location, and Figure 9 for dimensional requirements.

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960.

KAA S:\zoning review\karol\planning\cdrc\developmentplan\D07-0008dpr.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents.
05/17/2007 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the landscape plan to show preserved-in place plants indicated on the native plant preservation plan.
DS 2-07.2.2.A.1.e

2) Revise the development plan to show the location of the street landscape border proposed on the landscape plan.
DS 2-05.2.4.X

3) Trees and shrubs are to be selected and located so that, at maturity, they do not interfere with existing on-site or off-site utility service lines or utility easements. LUC 3.7.2.6.B
Evaluate the potential conflicts with the 20" gas line pipeline, and revise as necessary.

4) Revise the native plant preservation plan calulations.
A) Clarify the absence of any values for Mit. in the Inventory Totals, while the inventory list includes many plants categorized as "Mit".

If "Mit' represents trees that are being removed that require mitigation, but RFS means the same thing, the calculations become confusing.

All plants in the inventory list should be identified as PIP, TOS, or RFS and the calculation are to include total mitigation for RFS and TOS and then a reduction of those based on preservation credit. Refer to DS 2-15 Exhibit 1. If there is a need to distinguish mitigation requirements for individual plants rather than the total per species, then use Mit. in addition to three standard classifications.

B) Submit the native plant preservation with an aerial photo.

C) Complete the mitigation calculations. List PIP credits and net mitigation on the NPP and landscape plan calculations.

D) All lettering and dimensions shall be the equivalent of twelve (0.12") point or greater in size. DS 2-05.2.1.A
Revise the table on sheet 1 of the landscape plan.


5) Show the entire parcel on the development plan at an engineering scale having no more than forty (40) feet to the inch per DS 2-05.2.1.D.

6) Show required sight visibility triangles on the landscape plan. Plant materials located within SVT's should consist of ground cover or low-growing vegetation of a species that will not grow higher than (30) inches. However, trees may be planted within SVT's provided that: A) The trunk caliper, at maturity, will not exceed twelve (12) inches in diameter; B) The lowest branch of any tree is at least six (6) feet above the grade of the street, and C) Trees are not planted in a line that could result in a solid wall effect when viewed from an angle. LUC 3.7.2.8 & DS 2-06

7) A native plant preservation plan is also required for any vegetation removal associated with the proposed new ingress/egress easement at the southern parcel boundary to
Rita Road.

RESUBMITTAL OF ALL PLANS IS REQUIRED
05/21/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D07-0008 GLOBAL SOLAR ENERGY NEW FACILITY/REVISED DEVELOPMENT PLAN
DATE: 5/21/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.



ES
05/22/2007 ANDY VERA ENV SVCS REVIEW Denied 1. DP does not identify access point, approach, maneuverability, or deminsions to compactor area. No detail or annotation regarding construction and design (i.e supplied power source, concrete pad, etc.) of compactor area. DS 6-01.3.A , 6-01.4.1 , & 6-01.4.3.

Please include with resubmittal of DP.
05/24/2007 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Denied 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR# 177734 May 24, 2007



DOWL Engineers
Attn: Richard Cordova
166 W. Alabama
Tucson, Arizona 85701

Dear Richard Cordova :

SUBJECT: Global Solar Energy- New Facility (Resubmittal)
D07-0008

Tucson Electric Power Company (TEP) has reviewed the plan submitted May 10, 2007. TEP is unable to approve the plan at this time. There are existing electrical facilities within the boundaries of this project. In order for TEP to approve the plan the facilities and easements must be depicted on the plans.

Enclosed is a copy of a TEP facility map showing the approximate location of the existing facilities. The detail of the plan on page two (2) does not include the west side of the project. This is where our facilities are located. Please provide a map that inducates that portion of the project. All costs associated with the relocation of the facilities in conflict will be billable to the developer.

Please resubmit two revised bluelines to Pima County Development Services Department for TEP’s review. You may contact the area Designer, Todd Stocksdale at 917-8715 should you have any technical questions.

Sincerely,



Henrietta Noriega
Office Specialist

hn
Enclosure
cc: P. Gehlen and F. Rodriguez, City of Tucson (by e-mail)
T. Stocksdale, Tucson Electric Power
06/06/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 6, 2007

Richard Corodova
DOWL Engineers
166 W Alameda
Tucson, Arizona 85701

Subject: D07-0008 Global Solar Energy Facility Development Plan

Dear Richard:

Your submittal of April 26, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Development Plan (Zoning, TEP, ESD, Fire, Landscape, DSD)

3 Copies Revised Landscape Plan (Zoning, Landscape, DSD)

2 Copies Revised NPPO Plan (Landscape, DSD)

2 Copies Approved Lot Split Documents (Zoning, DSD)


Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 624-0384
dp-resubmittal