Permit Number: D07-0007
Parcel: 133170630

Address:
350 N WILMOT RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D07-0007
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/05/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/12/2007 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Engineering and Floodplain Review, 04/23/2007,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: St. Joseph's Hospital Neurosurgery Expansion
D07-0007, T14S, R15E, SECTION 07

RECEIVED: Development Plan and Drainage Statement on April 05, 2007

The subject project has been reviewed. The drainage statement was found acceptable for Development Plan purposes on the first submittal. The Development Plan is acceptable and it is hereby. Additional information may be required on the Grading Plan.
04/25/2007 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: D07-0007
St. Joseph's Hospital Neuro Expansion
Development Plan Resubmittal

TRANSMITTAL DATE: April 19, 2007

DUE DATE: May 3, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

Previous plans for this PAD and the existing hospital have not provided the correct number of required handicap accessible spaces per IBC Section 1106.3 and 1106.4

1106.3 - Hospital outpatient facilities. Ten (10) percent of patient and visitor parking spaces provided to serve hospital outpatient facilities shall be accessible.

1106.4 - Rehabilitation facilities and outpatient physical therapy facilities. Twenty (20) percent, but not less than one, of the portion of patient and visitor parking spaces serving rehabilitation facilities and outpatient physical therapy facilities shall be accessible.

The most current plan in review D07-0007 Neurosurgery Expansion identifies 2039 motor vehicle parking spaces provided, total accessible parking required as 31 spaces of which 8 are shown as van accessible.

An inventory of parking identifying those specific uses and the GFA dedicated to those uses as described in IBC Section 1106.3 and 1106.4 is required as part of the "Existing/Proposed Uses and Parking Calculations Table". The Table will call out the required amount of accessible spaces for each of these identified areas within existing structures within the PAD and provide a further break-down providing the number spaces that will be van accessible. This will then be continued for future development plans submitted for review.

Current existing parking and parking of recently approved plans for St. Joseph's Hospital medical complex to date, are to be brought up to ADA Federal requirements.

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960.

KAA S:\zoning review\karol\planning\cdrc\developmentplan\D07-0007dpr.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents.
05/02/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D07-0007 St. Joe's HOSPITAL Neuro. Expan. 04/27/07

() Tentative Plat
( X ) Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
( ) Other

CROSS REFERENCE: D06-0008 and D06-0016

NEIGHBORHOOD PLAN: PAD-13

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: May 3, 2007

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies with Plan Policies
( X ) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
( X ) Resubmittal Required:
( ) Tentative Plat
( X ) Development Plan
() Landscape Plan
( ) Architectural Review Board Approval Letter

REVIEWER: JBeall 791-4505 DATE: 4/27/07

Comments


It appears that previous plans for this PAD and the existing hospital have not provided the correct number of required handicap accessible spaces per IBC section 1106.3 and 1106.4. Current existing parking and parking of recently approved plans for St. Joseph’s Hospital medical complex to date, are to be brought up to ADA Federal requirements.

Please provide a revised/updated inventory of parking table that calls out the correct required amount of handicap accessible spaces for those identified areas within existing structures within the PAD and provide a further break-down providing the number of spaces that will be van accessible. This Table is to be updated and included on all future development plans submitted for review.
05/04/2007 ANDY VERA ENV SVCS REVIEW Approved
05/08/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 8, 2007

Steve Gregor
Gregor Engineering, Inc.
5232 East Pima Street, Suite A
Tucson, Arizona 85712

Subject: D07-0007 St. Joseph's Hospital Neuro Expansion Development Plan

Dear Steve:

Your submittal of April 5, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

3 Copies Revised Development Plan (Zoning, DUPD, DSD)

3 Copies Parking Inventory (Zoning, DUPD, DSD)









Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 319-1181