Permit Number: D07-0006
Parcel: 14029212B

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D07-0006
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/23/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/29/2008 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond 1) Canopy trees (defined in LUC 6.2.3) must be evenly distributed throughout the vehicular use area. Every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk).
Revise the landscape plan as necessary. Palm trees do not qualify as canopy trees. LUC 3.7.2.3.A, LUC 6.2.

The parking spaces along the south side of the building are not within 40 feet of canopy trees.

2) An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree . DS 2-07.2.2.A.2.e, LUC 3.7.2.3.A.1.c
Revise the landscape plan to indicate the minimum width and square footage of tree planters in (and adjacent to) vehicular use areas. Planters are to be measured from the inside edge of tree planters

3) Add the CDRC case number and any related case numbers to the landscape and native plant preservation plans (in the lower right corner). DS 2-07.2.1.B

4) Revise the notes on the right side of the plan for clarity.

RESUBMITTAL OF ALL PLANS IS REQUIRED
02/13/2008 JASON GREEN ENGINEERING REVIEW Approv-Cond DATE: February 13, 2008
SUBJECT: Tutor Time Daycare Development Plan- 4th Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: Parcel ID: 140-29-212B; T15S R14E Sec09 Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: D07-0006

SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised development plan, landscape plan, Drainage Statement (LEADS, Inc., 25JAN07, revised 13JUL07, revised 18OCT07, revised 17JAN08) and Geotechnical Engineering Report (Ricker-Atkinson-McBee-Morman and Associates, Inc, 10OCT06 with addendum 12OCT07 and 17OCT07). The Drainage Statement was reviewed for development plan purposes only. Engineering Division recommends conditional approval of the development plan at this time. The following comment must be addressed and reviewed for at Mylar submittal.

DEVELOPMENT PLAN COMMENT:
· DS Sec.10-02.10.9.1.8: Label and dimension the required clean out or manhole at the intersections of all H.D.P.E. pipes. 5 locations are missing clean out labels; the 3 junctions of the roof pipes along the west and east side of the building, the junction of the perforated pipe to the drain off pipe into the channel and a manhole is required for the junction of the pipe to the east side of the under ground retention system. Details for these junctions can be shown on the grading plan, however the Development Plan must at a minimum label the locations.

GRADING PLAN:
· DS Sec.11-01.2.1: A grading permit application (T08BU00093) has been submitted for this project and comments will be posted under a separate letter. A grading permit may not be issued prior to development plan approval.
· Please ensure the grading plan is consistent with the development plan, Drainage Statement and Geotechnical Report. Grading standards may be accessed at: http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf
· Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans (SWPPP) and text addressing stormwater controls for all areas affected by construction activities related to this development will be required with a grading plan submittal. For further information, visit www.adeq.state.az.us/environ/water/permits/stormwater.html.

GENERAL COMMENTS:

Engineering can review the revision required at Mylar submittal. If any department requires additional changes that significantly change the design of the plan Engineering will require an additional review.

For any questions or to schedule a meeting, call me at 520-837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
02/22/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES


February 22, 2008

Hank Hulbert
Leads, Inc.
2400 North Central Avenue, Suite 203
Phoenix, Arizona 85004

Subject: D07-0006 Tutor Time Daycare Development Plan

Dear Hank:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line comments, please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan.
AND
1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html.

Should you have any questions, please call me at 837-4919.


Sincerely,



Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (602) 254-1700
dpapproved
02/22/2008 PGEHLEN1 PIMA COUNTY WASTEWATER Approved Hi Patricia,

I just finished the review. It is now approved. We had conditionally
approved this on 10/31/07 for two simple corrections.

C.C. Patel, P.E.
Civil Eng. Manager
Pima County Development Review Division ( Wsatewater )