Permit Number: D07-0002
Parcel: 11451203C

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D07-0002
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/11/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/02/2007 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Add both the CDRC case number and any related case numbers to the landscape and native plant preservation plans. DS 2-07.2.1.B

2) Revise the landscape plans to use only native, indigenous plants for revegetation of the 30' scenic route buffer area.
LUC 3.7.5.2.D.1

3) If any disturbance occurs during construction or prior to permit application, the buffer area is to be revegetated with native plants indigenous to the site and the area
reconstructed to look as natural as possible. DS 2-06.7.1.B
Revise the plans to present a reconstructed buffer that looks as natural as possible.

3) Revise the plans to screen the proposed commercial land use and associated vehicular use areas from Bear Canyon Road in accordance with LUC 3.7.3 & LUC 3.7.2-I.

4) Revise the NPP mitigation calculations on the landscape plans to correspond with the NPP plan and include the required number of each species in the quantity column of the legend. DS 2-15.3.4.B

5) Revise the plans to clarify the requirements for dust control along the scenic route. Decomposed granite is not an acceptable treatment in the 30' buffer or the adjacent right-of-way area. Add notes as necessary.

Within the Scenic Route buffer area and the MS&R right-of-way, all areas between the MS&R right-of-way line and the existing street right-of-way that are disturbed by development shall be revegetated with native vegetation.

RESUBMITTAL OF ALL PLANS IS REQUIRED.
08/09/2007 ANDY VERA ENV SVCS REVIEW Approved
08/10/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

August 10, 2007

Kevin Hall
DCC Company
2828 North Country Club, Suite 100
Tucson, Arizona 85716

Subject: D07-0002 Ace Hardware - Bear Canyon Development Plan

Dear Kevin:

Your submittal of July 11, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Development Plan (Landscape, DSD)

2 Copies Revised Landscape Plan (Landscape, DSD)

2 Copies Revised NPPO Plan (Landscape, DSD)





Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 829-7856
dp-resubmittal