Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D07-0002
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/11/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/02/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Add both the CDRC case number and any related case numbers to the landscape and native plant preservation plans. DS 2-07.2.1.B 2) Revise the landscape plans to use only native, indigenous plants for revegetation of the 30' scenic route buffer area. LUC 3.7.5.2.D.1 3) If any disturbance occurs during construction or prior to permit application, the buffer area is to be revegetated with native plants indigenous to the site and the area reconstructed to look as natural as possible. DS 2-06.7.1.B Revise the plans to present a reconstructed buffer that looks as natural as possible. 3) Revise the plans to screen the proposed commercial land use and associated vehicular use areas from Bear Canyon Road in accordance with LUC 3.7.3 & LUC 3.7.2-I. 4) Revise the NPP mitigation calculations on the landscape plans to correspond with the NPP plan and include the required number of each species in the quantity column of the legend. DS 2-15.3.4.B 5) Revise the plans to clarify the requirements for dust control along the scenic route. Decomposed granite is not an acceptable treatment in the 30' buffer or the adjacent right-of-way area. Add notes as necessary. Within the Scenic Route buffer area and the MS&R right-of-way, all areas between the MS&R right-of-way line and the existing street right-of-way that are disturbed by development shall be revegetated with native vegetation. RESUBMITTAL OF ALL PLANS IS REQUIRED. |
| 08/09/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 08/10/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 10, 2007 Kevin Hall DCC Company 2828 North Country Club, Suite 100 Tucson, Arizona 85716 Subject: D07-0002 Ace Hardware - Bear Canyon Development Plan Dear Kevin: Your submittal of July 11, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 2 Copies Revised Development Plan (Landscape, DSD) 2 Copies Revised Landscape Plan (Landscape, DSD) 2 Copies Revised NPPO Plan (Landscape, DSD) Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 829-7856 dp-resubmittal |