Permit Number: D07-0001
Parcel: 12416103A

Review Status: Completed

Review Details: DEVELOPMENT PLAN

Permit Number - D07-0001
Review Name: DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/30/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/31/2007 JIM EGAN COT NON-DSD FIRE Approved
02/02/2007 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: February 01, 2007

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov

CC: Patricia Gehlen


SUBJECT: D07-0001 Elliot Electronics Supply: Development Plan(1/30/07)


Staff has no comments.
02/05/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Denied February 5, 2007
ACTIVITY NUMBER: D07-0001
PROJECT NAME: Elliot Electronics Supply
PROJECT ADDRESS: Tyndall Ave/23rd St
PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer

Resubmittal Required: Traffic Engineering does not recommend approval of the Development Plan; therefore a revised Development Plan is required for re-submittal.

The following items must be revised or added to the development plan.

1. Include a response letter with the next submittal that states how all comments have been addressed.

2. Tucson City Code Chapter 25 Section 38 requires a minimum driveway separation of 12'. The location of the proposed driveway along Tyndall Ave may create future access constraints to the adjacent lot on the south due to the minimum frontage to Tyndall Ave from that southern lot. Please provide a cross access agreement so that the southern adjacent lot has future access, and to prevent future access constraints for the adjacent lot. If the adjacent lot is to be combined with this lot then provide documentation confirming the combo.

3. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.


If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov
02/08/2007 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#176951 February 7, 2007

Arquitecto E. J. Ornelas
Attn: Eduardo Ornelas
100 N Stone, Suite 1002
Tucson, Arizona 85701

Dear Mr. Ornelas :

SUBJECT: Elliot Electronics Supply
D07-0001

Tucson Electric Power Company has reviewed and approved the development plan submitted January 30, 2007. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. TEP will need a full set of approved site, electrical load, paving off-site improvements and irrigation plans.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Ms. Mary Boice
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8732

Please call the area Designer Mike Kaiser at (520) 918-8244, should you have any questions.

Sincerely,


Elizabeth Miranda
Office Support Specialist
Design/Build
lm
Enclosures
cc: P. Gehlen and F. Rodriguez, City of Tucson (email)
M. Kaiser, Tucson Electric Power
02/08/2007 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
D07-0001
ARQUITECTO E. J. ORNELAS
ELLIOT ELECTRONICS SUPPLY

--------------------------------------------------------


Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
02/12/2007 FRODRIG2 OTHER AGENCIES PIMA ASSN OF GOVTS Approved Transportation Information
Rezoning, Plat, and Development Plan Reviews Provided by:
Pima Association of Governments
Data Services Department
Kristen Zimmerman
kzimmerman@pagnet.org
www.pagnet.org
This information is provided to assess the impact of the proposed development on surrounding traffic and roads.
X City of Tucson, Development Services Department, Community Design Review Committee
City of Tucson, Development Services Department, Rezoning
Town of Marana Planning Department
Case Number
Date
The transportation impact of this plan cannot be determined at this time; more detailed information regarding the
nature of the development is required.
This project has no associated transportation impacts.
399 Average number of daily trips (ADT) forecasted as a result of the proposed development
42,560 2-way capacity on nearest existing major street
36,693 Most recent (less than 3 years old) 2-way PAG traffic count on nearest existing major street
If the forecasted ADT is greater than 500 ADT, additional traffic and road considerations are noted below.
STREET IDENTIFICATION
Nearest existing major street
Is a road improvement planned as part of PAG's 5-Year Transportation Improvement Program? Yes No
(See http://www.pagnet.org/tip/ for more information on the PAG TIP program.)
VOLUME, CAPACITY, TRAFFIC GENERATION CONSIDERATIONS
(See http://www.pagnet.org/TPD/DataTrends/ for more information on local traffic volumes.)
2005 2030 2005 2030 2005 2030
TRANSIT AND BIKEWAYS CONSIDERATIONS
Existing bus service
(Route, frequency, distance from proposed development)
Existing bikeway
Number of Road Capacity Daily Traffic Volume (ADT)
D07-0001
2/2/2007
Estimated by PAG Traffic Model (ADT) Lanes
42,560
d07-0001.xls 2/2/2007
02/15/2007 AVERA1 ENV SVCS REVIEW Denied * No known landfills within 1000 ft of development.
* No provisions shown for on site refuse/recycling collection as required per development standards section 6-01.4.1A
02/16/2007 TIM ROWE PIMA COUNTY WASTEWATER Denied February 14, 2007

To: Eduardo Ornelas
E.J. Ornelas & Associates

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C. Patel, P.E., Civil Engineering Manager
Pima County Development Services Department
Development Review Division (Wastewater)

Subject: Elliot Electronic Supply
Development Plan – 1st Submittal
D07-001

The drawings for the proposed Development Plan for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



ALL SHEETS. Add the project number, D07-001 to the title block of each sheet. This number should be shown larger and bolder than any cross-reference numbers.

Provide a letter from PCWMD Development Services Section, written within the past 90 days, stating that the treatment and conveyance system capacity for this project is available. A capacity request form may be found at http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf

3. SHEET 1. The notes shown on the left top side of the drawing need to be grouped under GENERAL NOTES and PERMITTING NOTES.

4. SHEET 1. In the Legend, show symbols for existing public sewer with manhole. Label the cleanout and sewer line as proposed cleanout and proposed sewer line.

5. SHEET 1. Add a Permitting Note that reads:

A PROJECT CONSTRUCTION PERMIT MUST BE SECURED FROM THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT BEFORE BEGINNING ANY WORK ON THIS PROJECT.

6. SHEET 1. Show the slope and length of the proposed BCS.

7. SHEET 1. Show the rim and invert elevations of the proposed COs.

8. SHEET 1. Add a General Note that reads:

ON-SITE SANITARY SEWERS WILL BE PRIVATEAND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON APRIVATE BASIS.

9. SHEET 1. Show the information pertaining to the point of connection of the new 6-inch sewer line to an existing sewer line. If the existing sewer is a public sewer, label it as such, and show the Pima County plan number for this sewer with its size and slope, and show the necessary information about the existing manholes ( IMS number& rim and invert elevations) located immediately upstream and downstream of the planned connection point of the new sewer line.

10. SHEET 1. Label the 6-inch sewer line as PROPOSED BCS.

11. SHEET 1. Use different line types for existing and proposed sewers.

12. We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $50.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and the response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above comments, please do not hesitate to contact me.

Sincerely,



Chandubhai C. Patel, P.E.
Telephone: (520) 740-6563


Copy: Project File
02/16/2007 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D07-0001 ELLIOT ELECTRONICS SUPPLY/DEVELOPMENT PLAN
DATE: 2/16/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Correct 23th Street to 24th Street in Location Map.

Correct Legal Description to include Lots 1 and 2 and delete from Location Map.

Completely spell out suffixes for 23rd and Tyndall on sheets 1 and 2.

Provide “blank” Address Block on Sheet 1 (minimum size to be 3” X 5”).


es
02/27/2007 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Add the CDRC case number and any related case numbers (rezoning) to the landscape and native plant preservation plans. DS 2-07.2.1.B

2) Submit a copy of the Preliminary Development Plan and revise the plans to include a correct copy (per ordinance) of the conditions of rezoning. The included communication from the City Manager to the Mayor and Council is only a recommendation and is inappropriate for inclusion in the plan set. C9-89-30

3) The vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent vehicles from extending beyond the property lines; damaging adjacent landscaping, walls, or buildings and to prevent vehicles from accessing the alley. DS 3-05.2.3.C., C9-89-30
Revise the plans to provide a barrier to protect the proposed wall along the south property boundary, to protect the interior landscape border, to protect all other unpaved or landscape areas and to prevent alley access.

4) Revise the landscape plan to show the ultimate size of plants indicated by the spread of canopy, circumference of shrubs, or spread of ground cover. Revise the landscape plan symbols for canopy trees to reflect the mature size of the species used. DS 2-07.2.2.A.1.c

5) Revise the landscape plan to indicate the minimum width and square footage of tree planters in vehicular use areas. Planters are to be measured from the inside edge of tree planters. DS 2-07.2.2.A.2.e, LUC 3.7.2.3.A.1.c

6) Dimension the width of landscape borders on the landscape plan per DS 2-07.2.2.A.2.f.

7) Submit an irrigation plan. LUC 3.7.4.5.C

8) Submit a native plant preservation plan prepared by a plant professional per DS 2-15.0 or an application for exception. LUC 3.8.4.2

9) Landscape plans shall include a summary of Native Plant Preservation requirements identify existing plants to remain in place on the landscape plan. DS 2-07.2.2.A.1.e

10) A Native Plant Preservation is required for plants in the adjacent right of way. Show any existing plants to remain in the right of way.

11) Revise the development and landscape plans to provide a thirty-inch high screen along the Tyndall Avenue frontage. LUC Table 3.7.2-I

12) Revise all plans to show the location of on-site refuse storage and provide appropriate landscaping and screening per LUC Table 3.7.2-I. DS 6-01.4.1

13) Revise the landscape plan to show the extent of supplementary irrigation in each planting area provided by water harvesting methods. Show the amount and disposition of flow and indicate drainage points from buildings and paved areas. DS 2-07.2.2.C


RESUBMITTAL OF ALL PLANS IS REQUIRED
02/28/2007 FRODRIG2 COT NON-DSD REAL ESTATE Approved No comment
03/02/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D07-0001 Elliot Electronics Supply 03/02/07

() Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-89-30

NEIGHBORHOOD PLAN: Greater South Park

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 02/28/07

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
(XXXX) Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies with Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: drcorral 791-4505 DATE: 02/27/07
03/05/2007 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed
03/05/2007 ED ABRIGO PIMA COUNTY ASSESSOR Passed
03/14/2007 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: D07-0001
Elliot Electronics Supply
Development Plan

TRANSMITTAL: 03/14/07

DUE DATE: 2-28-07

COMMENTS:

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 02/27/08.

2. DS 2-05.2.2.A.1 List the names, addresses, and telephone numbers of the primary property owner of the site and developer of the project.

3. DS 2-05.2.2.B.1 List as a general note: "Existing zoning is ____." Number the general notes in order for easier reading.

4. DS 2-05.2.2.B.2 Case number D07-0001 has been assigned to this development plan (DP). Please place this number in the right corner of all sheets of the development plan, landscape plan, NPPO, and any other associated sheets.

5. DS2-05.2.2.B.3 The proposed use of this project is "General Merchandise Sales "34" subject to: 3.5.9.2.A." Remove all references to "Wholesale Use", including in the parking calculations. FYI: There is no such use group as "Retail/Wholesale Use Group."

6. DS 2-05.2.3.B If applicable, all easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated.

7. DS 2-05.2.4.A A lot combination has been recorded creating one lot. A Covenant Regarding Development and Use of Real Property will be required to be completed and recorded. This form is available on line at the City of Tucson web site. Provide docket and page recording information on the site plan.

8. DS 2-05.2.4.D.3 Provide a barrier along the east property line to prevent vehicular access.

9. DS 2-05.2.4..I Revise the notes for the required and proposed setbacks to the requirements as per LUC Sec. 3.2.6.4. with a development designator of "DD". North-required 10', East ---required 0', South ---required 11/2 times the height of the structure, West----required 20' or 11/2 times the height of the structure. Provide the proposed setback in the notes and on the site plan.

The indicated height of the structure is indicate on the site plan as 14'. In the notes the height is indicated as 15'. Clarify.

Based on the structure height of 15' the required setback from the south property line is 22'-6". Revise plans and notes.

Per rezoning case #C9-89-30 the maximum building height shall be twenty five (25) feet. Revise notes to indicate the correct maximum building height.

Per rezoning case #C9-89-30 Storage shall be enclosed in the proposed building. Add a note to the site/development plan clearly indicating compliance with this rezoning condition.

Provide a separate document clearly indicating how each of the rezoning conditions has been complied with.

10. DS 2-05.2.4.K Provide a pedestrian circulation path connecting to the sidewalk located along Tyndall Ave. Including sidewalk, crosswalk, handicap ramps, etc. See DS 2-08.3.1

Access ramps at crosswalks connecting to sidewalks must be provided. In addition Truncated Dome (early warning systems) must be added to all access ramps where transitioning from the pedestrian area to the vehicular use area or at HC access aisles transitioning to the sidewalk area.

Provide a detail of the handicap ramp clearly indicating slopes and location of truncated domes.

The truncated domes indicated in note #5 are to be located where the access aisle for the handicap parking space meets the landing and must be a minimum of 24" in width.

11. DS 2-05.2.4.N Provide dimensions on the footprint of the structure.

12. DS2-05.2.4.O Per LUC Sec. 3.4.5 for a Retail Trade Use Group (General Merchandise Sales) a loading zone per Sec. 3.4.5.3 is required. FYI: one 12 x 35 loading zone is all that is required. Revise note and plan if this smaller loading zone is to be used.

13. DS 2-05.2.4.P The parking calculations provided are for the incorrect use. General Merchandise Sales per LUC Sec.3.3.4 under the Retail Use Group requires parking spaces being provided at the rate of 1:200 sq. ft. of GFA. This project will require 45 parking spaces. A redesign of the project will be required or you may apply for parking space reduction through a Board of Adjustment Variance ( the variance may or may not be approved).

Revise notes to correct the required and proposed parking space requirements.

Provide on detail 1 of 3 the maximum slope of the handicap parking space and access aisle as per ANSI Standards. (maximum allowed 1:48)
Provide a detail of the required handicap parking signage. FYI: The minimum distance from grade to the bottom of the handicap sign per City of Tucson standards is seven (7) feet. The handicap sign indicated on detail 1 of 3 cannot be located in the vehicle overhang area. Relocate.

14. DS 2-05.2.4.Q The required class 2 bicycle parking spaces cannot be located inside of the building.

Two class 2 bicycle parking spaces are all that is required when less than 50 vehicle parking spaces are provided.

Please provide a dimensioned detail class 2 bicycle parking spaces. Be aware that that development standard 2-09 has been revised. Once provided and reviewed further comments may result. The revised standards can be found at the DSD web site: http://www.tucsonaz.gov/dsd/Codes___Ordinances/DevStd209.pdf

Please provide a plan view detail of the proposed class 2 bicycle parking spaces. Single rack spaces placed in a row will allow a minimum of seventy -two (72) inch length per bicycle parking space and a minimum of thirty (30) inches between outer spaces of racks. A five (5) foot wide access aisle measured from the front or rear of the seventy-two (72) inch long parking space will be provided beside each row. Lighting will be provided such that all facilities are thoroughly illuminated and visible from adjacent sidewalks, parking lots, or buildings, during working hours. The surface of the facility can be surfaced the same as for motor vehicle parking or with a minimum of one (1) inch thickness of one-fourth (1/4) inch aggregate material.
DS 2-09.5.1, DS2-09.5.2, DS 2-09.5.4, & DS 2-09.6.2

Per DS 2-09.4.1 Class 2 bicycle parking facilities will be located no more than fifty (50) feet from the main building entrance(s) and will be along the front side of the building as well as along other sides of the building that has an entrance. Bicycle access through the development will be separate from the pedestrian ways. Vehicular access may be used as bicycle access. Bicycle access to a parking facility may cross a pedestrian way at a right angle (DS2-09.3.2). Multiple rack bicycle parking require a minimum thirty (30) inches between outer spaces of posts or racks (DS 2-09.5.1.A). Please review the revised DS 2-09 and provide the necessary corrections to the bicycle parking as required. Once changes are provided and reviewed further comments may result.

The type of rack required must provide two-point support for bicycles. Please review DS 2-09.8.0 Figure 2 - 7 for acceptable and unacceptable rack designs, Figure 8 for rack location, and Figure 9 for dimensional requirements.

Please review the revised DS 2-09 and provide the necessary corrections to the bicycle parking as required. Once changes are provided and reviewed further comments may result.

15. DS 2-05.2.4.V Please indicate the location and type of postal service to assure there are no conflicts with other requirements. If mail is to be delivered to an area within a building please state so on the plan.

16. DS 2-05.2.4.W Indicate the locations and types of proposed signs (wall, freestanding, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Also indicate if there are existing billboards on site. Billboards will be required to meet all LUC requirements as stated in LUC Sec. 3.5.4.26. If none exists please state so.

17. Depending on changes to the plan and responses to the above comments further comments may be forth coming.


If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.

TLS C:\planning\cdrc\developmentplan\D07-0001dp.doc
03/26/2007 LOREN MAKUS ENGINEERING REVIEW Denied DATE: March 26, 2007

To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Loren Makus, EIT
Engineering Division


SUBJECT: Elliot Electronics Supply
Development Plan D07-0001 (First Review)
T14S, R14E, Section 19

RESUBMITTAL REQUIRED: Revised Development Plan, Revised Drainage Statement
The development plan has been reviewed by the Engineering Division and we do not recommend approval at this time. The following comments must be addressed:

1. Revise the drainage statement to allow offsite drainage to enter the site in the manner and location it has historically.
2. Revise the drainage statement and development plan to show the existing and proposed floodplain boundary. The floodplain is the area that is subject to inundation by a 1- percent chance storm where the discharge is at least 100 cubic feet per second. Add a note indicating that a floodplain use permit will be required for the development. (See Development Standard 2-05.2.2.C.2)
3. Show water surface contours at a minimum of two locatons.
4. DS 2-05.2.1 B. All mapped data on the development plan shall be drawn at an engineering scale having no more than forty (40) feet to the inch. This scale is the minimum accepted due to the detailed information required to show compliance. It also affords greater clarity after photographic reduction (microfilming) for record keeping purposes.
5. DS 2-05.2.1 H. List the contour interval near the north arrow.
6. Keynote 2 indicates that a driveway apron per standard detail 206 will be used. The plan view indicates curb returns. Revise the plans so the plan view matches the notes.
7. Show more existing and proposed spot elevations on the parcel. Show that drainage patterns will be achieved and positive drainage from the building will be provided. A grading permit will be required for this project.
8. Clearly indicate with section details, how the grades will be made from the street grade through the property. Show how the new street pavement and curbs will be accommodated.
9. Clearly show the water harvesting areas in the section details. Show sufficient grade information to show that the water harvesting areas will be level to collect water. Show how water will be directed to these areas.
10. Key note 4 doesn't appear to be used on the plan. Show the location on the plan where cans will be placed. Aerial photos inicate that there is vegetation within the alley. Show how alley access will be achieved.
11. Include the required drainage notes from the Development Standards. (DS 2-05.2.2.C)
12. Provide legend entries for all of the diagonal line drawing elements in the plan view.
13. Add the required streets notes from the Development Standard (DS 2-05.2.2.D)
14. Provide the correct bearings for the lot lines. The bearings shown appear to be shifted by about 90 degrees.

If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
03/27/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 27, 2007

Eduardo J. Ornelas
Arquitecto E. J. Ornelas
100 North Stone Avenue, #1002
Tucson, Arizona 85701

Subject: D07-0001 Elliot Electronics Supply Development Plan

Dear Eduardo:

Your submittal of January 30, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

8 Copies Revised Development Plan (Traffic, ESD, Wastewater, Addressing, Landscape, Zoning, Engineering, DSD)

4 Copies Revised Landscape Plan (Landscape, Zoning, Engineering, DSD)

2 Copies Revised NPPO Plan (Landscape, DSD)

2 Copies Revised Drainage Statement (Engineering, DSD)

2 Copies Recorded Lot Combo Covenant (Zoning, DSD)

Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 624-0747
dp-resubmittal