Permit Number: D06-0060
Parcel: 99999999A

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D06-0060
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/10/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/14/2008 JOE LINVILLE LANDSCAPE REVIEW Approved
04/22/2008 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: Midvale Commercial Center
D06-0060
Development plan Revision

TRANSMITTAL DATE: April 22, 2008

DUE DATE: April 24, 2008

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. D.S. 2-05.2.4.D.3 There appears to be a parking area access lane (PAAL) adjacent to the new loading dock. It does not appear to meet the minimum width requirements for a two-way PAAL, twenty-four (24) feet. Provide a dimension for this PAAL. If it is to be one-way show how access will be controlled i.e. signage, pavement markings etc.

2. D.S. 2-05.2.4.K The revised handicapped access ramps shown on the south side of Area #4 do not appear to work. Detail 1 Sheet DP5 does not match what is shown on the plan. A minimum four (4) foot landing is required at the top of ramp.

3. D.S. 2-05.2.4.O It appears that the dimensions have for the proposed loading dock have moved, please re-align.

4. D.S. 2-05.2.4.O The loading space calculation is incorrect. There are only ten (10) loading spaces shown on the plan and the calculation shows thirteen are provided.

5. D.S. 2-05.2.4.O Show how the proposed loading docks will be accessed by large delivery vehicles.

6. Zoning has been informed that a possible use for Area #5 & 6 is a Good Will or similar use. For your information if this type of use is proposed no collection of use goods is allowed on site, retail sales only.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\cdrc\developmentplan\D06-0060dpR.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, and additional requested documents.
04/24/2008 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond DATE: April 24, 2007
TO: Patricia Gehlen; CDRC Manager
SUBJECT: Midvale Commercial Center Lot 2 Revised Development Plan Engineering 3rd resubmittal review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: D06-0060

SUMMARY: The revised Development Plan Revision sheets were submitted for review. Development Services Department Engineering recommends conditional approval of the Development Plan due to maneuverability issues pertaining to solid waste pick-up and loading zones.

DEVELOPMENT PLAN CONDITIONS:
1) DS Sec.2-05.2.3.B: Submit the revised Development Plan addressing the following comments:
a) Address the following comments for sheet DP 3:
i) Clarify and delineate access and maneuverability into the loading zones west of Area #7 and Building #10.
ii) Parking area east of Area #11 shows parking stalls that are too short due to raised medians at the north and south ends of these 12 parking spaces. Vehicles entering drive-thru must be considered as they maneuver around parked cars in these parking stalls. Assure sufficient parking stall width is provided and reflected in median design.
iii) It appears that sidewalk scuppers are indicated on planview, yet no keynote is provided. Clarify.
b) Address the following comments for sheet DP 4:
i) Submit and clarify cross access easement in Tract 1 lot 1 needed for proposed back-up maneuver for loading dock at north end of Area #3.
ii) At north west corner of Area #5/6, clarify maneuverability of loading zone.
iii) Clarify and delineate access and maneuverability into the solid waste areas and loading zones northwest of Area #4.
iv) It appears that sidewalk scuppers are indicated on planview and called out on keynote list, yet not labeled with keynotes on planview. Clarify.
2) On sheets DP2 - DP4, a dashed line is indicated that surrounds the Wal-Mart and Areas #2-6. Clarify what this line is in the legend.

A grading plan review will be required prior to issuance of a grading permit. If you have questions, call me at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
04/29/2008 ANDY VERA ENV SVCS REVIEW Denied 1. Although four refuse/recycle enclosures would not work for the area behind #5/6 it will still require to provide an additional single within the immediate area to support all potential business types.

2. The 12 ft PAAL to the west side of the dock area for #5/6 appears to be too narrow. The service vehicle conflicts with the vertical curb or the west side of the dock before it completes its maneuver.

Please provide corrections on resubmittal.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
04/30/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

April 30, 2008

Thomas Sayler-Brown
SBBL
1001 North Alvernon Way, Suite 105
Tucson, Arizona 85711-1019

Subject: D06-0060 Midvale Commercial Center Revised Development Plan

Dear Thomas:

Your submittal of April 11, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

4 Copies Revised Development Plan (ESD, Zoning, Engineering, DSD)

3 Copies Revised Landscape Plan (Zoning, Engineering, DSD)






Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 620-0535