Permit Number: D06-0055
Parcel: 141185710

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D06-0055
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/20/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/20/2007 ANY ENGINEERING REVIEW Approv-Cond To: Patricia Gehlen DATE: February 20, 2007
CDRC/Zoning Manager FROM: Paul Machado
Engineering Division

SUBJECT: Springs Gymnastics, 9694 E. Rita Commerce Dr.
Development Plan D06-0055 (Second Review)
T15S, R15E, Section 28

RESUBMITTAL REQUIRED: None.

The Development Plan (DP) has been approved conditionally. Revise per the following comments.

Development Plan:

1. Please include a response letter to the comments along with the corrected copies of the DP.
2. Add the recording information and/or the separate grading plan number for the temporary cul-de-sac on the DP.
3. Include sheet C-2, the grading plan, with the set of the Development plan. The Development plan and the Grading plan are separate reviews and each is its own entity. Also the Grading plan may have to be re-numbered.
4. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. Key note number 15 on sheet C-1 refers to the grading plan for more information, yet the grading plan does not contain any more info. on the truncated domes. Revise as necessary.
5. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. This comment pertains to the temp. cul-de-sac.
6. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Include the datum in the description, i.e.: NAVD 88 or NVGD 1929. Correct the title for the Basis of Elevation. Per previous comment.
7. Replace General note no. 12 on sheet C-2 with "…..City of Tucson Development Standard 11-01.0 Excavation and Grading.
8. Correct the Book and Page in the "Basis of Bearing" description. It should read Bk. 49 instead of Bk. 46.
9. Explain note number 22 of the "General Grading - Paving - Drainage notes on sheet C-2. This project does not contain any new public roads.



Drainage Report:
1. The DR has been accepted for Tentative Plat purposes only. Final review and acceptance of the DR will be done at the grading plan stage.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@ci.tucsonaz.govs
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/9694 E. Rita Commerce Dr. CDRC 2
02/20/2007 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D06-0055 SPRINGS GYMNASTICS/REVISED DEVELOPMENT PLAN
DATE: 2/20/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1.) Per comment letter dated 1/19/07 correct docket 10506, page 1339 to Book 49, Page 34 in Legal Description.





es
02/20/2007 TERRY STEVENS ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: D06-0055
Springs Gymnastics
Development Plan

TRANSMITTAL: 02/20/07

DUE DATE: 02/27/07

COMMENTS:

1. The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements.

If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.

C:\planning\cdrc\developmentplan\D06-0055dpa.doc
02/20/2007 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D06-0055 SPRINGS GYMNASTICS/REVISDDEVELOPMENT PLAN
DATE: 2/21/07



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE: APPROVED ON CONDITION THAT:

1.) Correct docket 10506, page 1339 to Book 49, Page 34 in Legal Description of Title Block on mylar.

Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.


ES
02/21/2007 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond 1) Revise the landscape plan to relocate plants from the sight visibility triangle at the Rita Commerce Drive ingress/egress location that exceed thirty inches in height.
The Desert spoon should be moved.

2) Screening is required for the Rita Commerce Drive frontage per LUC Table 3.7.2-I. Revise the plans to screen the parking areas within 100 feet of the street.

3) If the hammerhead turnaround is to be temporarilly located along Rita Commerce Drive in lieu of the required street landscape border a bond is required to assure completion of the proposed landscape improvements. The bond will be required prior to landscape inspection approval and the amount should cover for the actual costs of pavement removal, landscape/irrigation installation, and curb replacement. LUC 2.4.8.2.G

4) An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree in the vehicular use area. Revise the development plan, landscape plan, and grading plan to comply. LUC 3.7.2.3
02/21/2007 AVERA1 ENV SVCS REVIEW Approved * Per Paul Machado detail of enclosure met development standards and provided for the 10 ft clear.
02/27/2007 PGEHLEN1 PIMA COUNTY WASTEWATER Approv-Cond February 27, 2007

TO: Joaquin Rincon
Civil Works Engineering

THRU: Patricia Gehlen, CDRC Manager
City of Tucson, Development Services Department

FROM: Chandubhai C. Patel, P.E., Civil Engineering Manager
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Springs Gymnastics School
Development Plan – 3rd Submittal
D06-055


The proposed sewer collection lines to serve the above-referenced development have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ), and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


This development is proposing to connect its new 4-inch BCS to the 8-inch public sewer G-2006-152. However, this public sewer is not existing, but currently going through the design review. Therefore, please be aware that the sewer service for Spring Gymnastics will not be available until this sewer G-2006-152 is constructed, inspected and accepted by the PCWMD in the county sewerage system.

SUBJECT TO THE ABOVE, the Pima County Department of Environmental Quality and the Wastewater Management Department hereby CONDITIONALLY approve the above referenced submittal of the development plan as received by us on February 20, 2007. THERE IS NO NEED TO RESUBMIT THE DEVELOPMENT PLAN.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in any activity which may cause or contribute to air pollution.

If you have any questions regarding the above comments, please do not hesitate to contact me.






Sincerely,



Chandubhai C. Patel, P.E.
Telephone: (520) 740-6563

Copy: Project file
02/27/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

February 27, 2007

Wayne Scheibe
Wayne Scheibe Architect
40 North Swan Road, #219
Tucson, Arizona 85711

Subject: D06-0055 Spring Gymnastics Development Plan

Dear Wayne:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line comments, please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 290-1370 Also Fax to 320-0191
dpapproved