Permit Number: D06-0053
Parcel: 13336014G

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D06-0053
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/30/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
02/07/2007 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: D06-0053
Tucson Old Pueblo Credit Union
Development Plan Resubmittal

TRANSMITTAL DATE: February 6, 2007

DUE DATE: February 26, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please correct the number of provided parking spaces in general note 7. The provided amount is currently shown as twenty-six (26) yet twenty-eight (28) spaces are shown in plan view and in calculations on sheet 1 of 2.

2. Please revise the bicycle parking detail to provide a minimum of thirty (30) inches between spaces of racks and thirty (30) inches from adjacent walls of buildings. Please refer to figure 9 of DS 2-09.8.0.

3. Please assure that truncated domes are provided at all access ramps, sidewalk area leading into access aisles, and any other pedestrian areas that are flush to the vehicle use area.
ANSI 406.12, ANSI 705

4. All changes, modifications, and/or corrections must be made on all applicable plans including the development plan, landscape plan, and NPPO. Once changes, modifications, and/or corrections are made and reviewed further comments may result.


If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\developmentplan\D06-0053dpr.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents.
02/09/2007 AVERA1 ENV SVCS REVIEW Approved * Service access and approach to enclosure works.
* Enclosure detail provides for the required 10 ft clear as shown.
02/13/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D06-0053 TUCSON OLD PUEBLO CREDIT UNION/REVISED DEVELOPMENT PLAN
DATE: February 13, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE:

Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.







jg
02/15/2007 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond The site is required to include screening per LUC Table 3.7.2-I. Revise the development plan as necessary to include the required screen along Stoner Avenue ( as shown on the landscape plan).
03/05/2007 PAUL MACHADO ENGINEERING REVIEW Approv-Cond To: Patricia Gehlen DATE: March 5, 2007
CDRC/Zoning Manager

SUBJECT: Tucson Old Pueblo Credit Union, 9725 E. Broadway Blvd.
Development Plan D06-0053 (Second Review)
T14S, R15E, Section 11

RESUBMITTAL REQUIRED: None.

Development Plan:

1. The DP is approved conditionally providing the following comments are addressed.
2. Label the existing and future sight visibility triangles per D.S. 2-02.2.1.10. Show the SVT's at the intersection of Broadway Blvd. and Stoner Ave (NW corner).
3. Add a standard wheel chair ramp at the same corner mentioned in comment no. 2.

Drainage Report:
1. The DR has been accepted for DP purposes only.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@ci.tucsonaz.govs
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/9725 E. Broadway Blvd. CDRC Credit Union 2
03/09/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 9, 2007

Antony C. Tsang
A.C. Tsang Engineering Group, Inc.
4626 East Fort Lowell, suite S
Tucson, Arizona 85712

Subject: D06-0053 Tucson Old Pueblo Credit Union Development Plan

Dear Tony:

Your submittal of January 29, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

3 Copies Revised Development Plan (Zoning, Engineering, DSD)

3 Copies Revised Landscape Plan (Zoning, Engineering, DSD)





Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 325-0979
dp-resubmittal