Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D06-0053
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/29/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 01/30/2007 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 02/07/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D06-0053 Tucson Old Pueblo Credit Union Development Plan Resubmittal TRANSMITTAL DATE: February 6, 2007 DUE DATE: February 26, 2007 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Please correct the number of provided parking spaces in general note 7. The provided amount is currently shown as twenty-six (26) yet twenty-eight (28) spaces are shown in plan view and in calculations on sheet 1 of 2. 2. Please revise the bicycle parking detail to provide a minimum of thirty (30) inches between spaces of racks and thirty (30) inches from adjacent walls of buildings. Please refer to figure 9 of DS 2-09.8.0. 3. Please assure that truncated domes are provided at all access ramps, sidewalk area leading into access aisles, and any other pedestrian areas that are flush to the vehicle use area. ANSI 406.12, ANSI 705 4. All changes, modifications, and/or corrections must be made on all applicable plans including the development plan, landscape plan, and NPPO. Once changes, modifications, and/or corrections are made and reviewed further comments may result. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D06-0053dpr.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents. |
| 02/09/2007 | AVERA1 | ENV SVCS | REVIEW | Approved | * Service access and approach to enclosure works. * Enclosure detail provides for the required 10 ft clear as shown. |
| 02/13/2007 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: D06-0053 TUCSON OLD PUEBLO CREDIT UNION/REVISED DEVELOPMENT PLAN DATE: February 13, 2007 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. jg |
| 02/15/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | The site is required to include screening per LUC Table 3.7.2-I. Revise the development plan as necessary to include the required screen along Stoner Avenue ( as shown on the landscape plan). |
| 03/05/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Approv-Cond | To: Patricia Gehlen DATE: March 5, 2007 CDRC/Zoning Manager SUBJECT: Tucson Old Pueblo Credit Union, 9725 E. Broadway Blvd. Development Plan D06-0053 (Second Review) T14S, R15E, Section 11 RESUBMITTAL REQUIRED: None. Development Plan: 1. The DP is approved conditionally providing the following comments are addressed. 2. Label the existing and future sight visibility triangles per D.S. 2-02.2.1.10. Show the SVT's at the intersection of Broadway Blvd. and Stoner Ave (NW corner). 3. Add a standard wheel chair ramp at the same corner mentioned in comment no. 2. Drainage Report: 1. The DR has been accepted for DP purposes only. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@ci.tucsonaz.govs Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/9725 E. Broadway Blvd. CDRC Credit Union 2 |
| 03/09/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES March 9, 2007 Antony C. Tsang A.C. Tsang Engineering Group, Inc. 4626 East Fort Lowell, suite S Tucson, Arizona 85712 Subject: D06-0053 Tucson Old Pueblo Credit Union Development Plan Dear Tony: Your submittal of January 29, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Development Plan (Zoning, Engineering, DSD) 3 Copies Revised Landscape Plan (Zoning, Engineering, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 325-0979 dp-resubmittal |