Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D06-0052
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/06/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/14/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D06-0052 Washington Federal Savings Development Plan Resubmittal TRANSMITTAL DATE: March 14, 2007 DUE DATE: April 3, 2007 COMMENTS: The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 1. Please revise width of the drive through lane to eleven feet for stacking spaces 3-6 and revise the pass thru PAAL width to twelve (12) feet adjacent to stacking spaces 3-6. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D06-0052dpr1.doc |
| 03/15/2007 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | Right of way dedication is complete, no further comments. |
| 03/16/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | TO: Patricia Gehlen; CDRC Coordinator DATE: March 16, 2007 SUBJECT: Engineering review of the Development Plan. The activity number is D06-0052. SUMMARY: The Washington Federal Savings Development Plan and Drainage Report were received by Engineering on March 6th, 2006. Engineering has reviewed the received items and recommends approval of the Development Plan and the Drainage Report. DEVELOPMENT PLAN IS APPROVED GENERAL COMMENTS 1. A site application card (yellow card) with the CDRC approved development plan must be stamped with signatures for DSD site approval by the following reviewing sections; Fire, Zoning, Handi-cap, Engineering, and Landscape/NPPO. The development plan may be walked through for stamps and site card sign off. No fees are involved in re-stamping the development/tentative plat plans as an approved site plan. 2. Once the process above is complete submit a copy of the approved development plan stamped for site plan approval with two copies of the grading plan, the (green) grading application and a (blue) floodplain use permit application for the grading plan submittal. |
| 03/19/2007 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: D06-0052 WASHINGTON FEDERAL SAVINGS/REVISED DEVELOPMENT PLAN DATE: March 19, 2007 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. jg |
| 03/21/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES March 21, 2007 Antony C. Tsang A.C. Tsang Engineering Group, Inc. 4626 East Fort Lowell, Suite S Tucson, Arizona 85712 Subject: D06-0052 Washington Federal Savings Development Plan Dear Tony: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per on-line comments, please submit the following documents for sign-off. 1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). AND 1 Double Matte right-reading Océ or Photo Mylar of the Development Plan. The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. In order to ensure a rapid review and approval of the mylars please have the City of Tucson approval stamp placed on each sheet of the mylar set near the title block. The approval stamp can be located at: http://www.ci.tucson.az.us/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 325-0979 |