Permit Review Detail
Review Status: Completed
Review Details: REVISION - DEV PLAN
Permit Number - D06-0047
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/01/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 02/02/2011 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 02/02/2011 | DAVID MANN | COT NON-DSD | FIRE | Approved | |
| 02/04/2011 | RONALD BROWN | ZONING HC | REVIEW | Denied | SHEET C-1.2 1. Delete all the detectable warnings around the accessible parking space and aisle. 2. A2.8% cross slope at the marked crossing is non-compliant with ICC (ANSI 117.1), Section 403.3. 3. The sloped area in the accessible route shown with a 7.58% slope must meet the ramp requirements of ICC (ANSI 117.1), Section 405 complete with handrails. SHEET C-1.3 4. Detail B: Please add a "Van Accessible" sign. 5. Detail C: a. Please delete the detectable warnings at the accessible parking space and aisle. b. Maximum slope in all directions for the accessible parking space and the aisle is to be no more than 2% not 1:12 as shown. Reference ICC (ANSI 117.1), Section 502.5. 6. Detail "O": Ditto comment 1 above. END OF REVIEW |
| 02/10/2011 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Lot 29 Camino Abril, Industrial/Commercial Services Site Development Plan - Revision D06-0047 TRANSMITTAL DATE: February 10, 2011 DUE DATE: February 15, 2011 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. D.S. 2-05.2.4.K Per D.S. 3-05.2.2.B.1 provide a striped pedestrian refuge along the west side of the building from the end of the sidewalk to the south end of the building. 2. D.S. 2-05.2.4.P Provide a floor plan for the proposed use showing the number of proposed repair bays. Based on the most current arial photo's there are at least two repair bays (over head doors) on the existing building. That said per LUC Section 3.3.4, COMMERCIAL SERVICES USE GROUP, Automotive - Minor Service and Repair, bays provided. Five (5) spaces per bay for each additional bay provided up to and including four (4) bays. Two (2) spaces per bay for each additional bay provided over four (4) bays. That said the minimum number of vehicle parking spaces required would be 18. A Board of Adjustment for Variance would be required. 3. D.S. 2-05.2.4.Q Provide directional signage to the bicycle parking. This signage should be located on the front of the building clearly visible from the street. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and a copy of the proposed floor plan for the building.. |
| 02/15/2011 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Revise the plans to provide minimum width required for the tree planters in the west portion of the site per LUC 3.7.2.3.A.1.c. |
| 02/16/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES February 16, 2011 Jeff Stanley Stanley Engineering & Drainage P.O. Box 1888 Tucson, Arizona 85702 Subject: D06-0047 EAST CAMINO ABRIL LOT 29 Development Plan REVISION Dear Jeff: Your submittal of February 15, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 4 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 4 Copies Revised Development Plan (Zoning HC, Zoning, Landscape, PDSD) 3 Copies Revised Landscape Plan (Zoning, Landscape, PDSD) 2 Copies Proposed Floor Plan of Building (Zoning, PDSD) Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 624-0993 |