Permit Number: D06-0047
Parcel: 141113920

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D06-0047
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/29/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/12/2007 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: D06-0047
East Camino Abril Lot 29
Development Plan Resubmittal

TRANSMITTAL DATE: June 9, 2007

DUE DATE: June 26, 2007

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please add truncated domes at the entrance to the cross walk. The domes are to provide a warning and direction to visually impaired individuals of a vehicle use area. The current placement would direct that person into fencing or directly into traffic. The area covered by the truncated domes shall be twenty-four (24) inches deep and extend the width of the crosswalk.
ANSI 406.12, ANSI 705

2. Detail O-3 is for trash pick-up. Please denote how large semi-trucks can maneuver into the proposed off-street loading spaces. To further clarify this site does not require that an additional space be provided. The off-street loading calculation is to show both tables indicating that providing one space meets both requirements depending on the actual principal use that will occupy the site. Adding the second table was not intended to make the applicant supply two off-street loading spaces. The total square footage did not exceed 10,000 sq. ft. (both building and work area). A single off-street loading space 12'x55' is required and will meet the requirements of both tables. What must be demonstrated is the vehicles ability to maneuver into and out of the space without crossing into or reducing parking spaces.

Per LUC Sec. 3.4.4.2.A: A street may be used for maneuvering of a delivery vehicle into, or out of, a loading space, provided it is for a use with only one (1) space, and if:
1. The street is not shown on the Major Streets and Routes (MS&R) Plan; or
2. The street is not a local residential street; or
3. The street does not abut a residential zone within the same block or within three hundred (300) feet of the nearest point of access to the loading zone. The three hundred (300) foot distance does not apply to the opposite side of a major street.

3. Please dimension the distance between the building and the southwest property line.
DS 2-05.2.4.I

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960.

KAA S:\zoning review\karol\planning\cdrc\developmentplan\D06-0047dpr1.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan.
06/15/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
06/18/2007 PAUL MACHADO ENGINEERING REVIEW Approved
07/03/2007 ANDY VERA ENV SVCS REVIEW Approved
07/09/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 9, 2007

Steve Wollerman
Southwestern Consulting Engineers, LLC
435 East 9th Street
Tucson, Arizona 85705

Subject: D06-0047 East Camino Abril Lot 29 Development Plan

Dear Steve:

Your submittal of May 30, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Development Plan (Zoning, DSD)











Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,

Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 628-1063