Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D06-0045
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/12/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/12/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D06-0045 East Camino Abril Lot 23 Development Plan Resubmittal TRANSMITTAL DATE: June 9, 2007 DUE DATE: June 26, 2007 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Please dimension the five (5) feet for a pedestrian refuge area between the building and PAAL along the northeast side of the building south of the loading space. 2. Please add truncated domes at the entrance to the cross walk on the east side. The domes are to provide a warning and direction to visually impaired individuals of a vehicle use area. The current placement would direct that person into fencing or directly into traffic. The area covered by the truncated domes shall be twenty-four (24) inches deep and extend the width of the crosswalk. ANSI 406.12, ANSI 705 3. Previous Comment - Please add the off-street loading requirements per Table 3 (LUC 3.4.5.3), one (1) space required for GFA between 1,500-10,000 sq. ft. to show that this requirement is being met. Also provide the required length and wide of both spaces and indicate that the most restrictive is being used. LUC 3.4.5.1 & LUC 3.4.5.3 This comment was made to have the off-street loading calculation show both tables indicating that providing one space meets both requirements depending on the actual principal use that will occupy the site. It was not intended to make the applicant supply two off-street loading spaces. The total square footage did not exceed 10,000 sq. ft. (both building and work area). A single off-street loading space 12'x55' is required and will meet the requirements of both tables. What must be demonstrated is the vehicles ability to maneuver into and out of the space without crossing into or reducing a parking space. Per LUC Sec. 3.4.4.2.A: A street may be used for maneuvering of a delivery vehicle into, or out of, a loading space, provided it is for a use with only one (1) space, and if: 1. The street is not shown on the Major Streets and Routes (MS&R) Plan; or 2. The street is not a local residential street; or 3. The street does not abut a residential zone within the same block or within three hundred (300) feet of the nearest point of access to the loading zone. The three hundred (300) foot distance does not apply to the opposite side of a major street. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D06-0045dpr1.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan. |
| 06/15/2007 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 06/18/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 07/03/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 07/06/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES July 6, 2007 Steve Wollerman Southwestern Consulting Engineers, LLC 435 East 9th Street Tucson, Arizona 85705 Subject: D06-0045 East Camino Abril Lot 23 Development Plan Dear Steve: Your submittal of May 30, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 2 Copies Revised Development Plan (Zoning, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 628-1063 |