| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/29/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/07/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D06-0043 Camino Café Lot 18 Development Plan Resubmittal TRANSMITTAL DATE: June 7, 2007 DUE DATE: June 26, 2007 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The off-street loading spaces appear to be difficult to maneuver in and out of. Staff suggests shifting the spaces to be side-by side against the back fence. This would allow trucks to make the radius to park and allow the vehicles to back-up and exit. If the main entry into the building is not on the east side the remainder of the required five (5) foot pedestrian refuge can be striped along the remainder of the building since area is intended for employees only. 2. Please place truncated domes on both sides of the crosswalk in the direction of travel. Domes allow sight impaired individuals to be alerted when they are entering a vehicle use area and provides a means direction. The current domes would direct individuals into the wrought iron fence and out onto the PAAL. ANSI 406.12, ANSI 705 3. Please strip the space in front of the proposed planter to discourage motor vehicles from utilizing this area as a parking space. 4. The landscape plan does not match the proposed development plan. Please revise to reflect current configuration. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D06-0043dpr1.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents. |
| 06/18/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 07/03/2007 | ANDY VERA | ENV SVCS | REVIEW | Denied | 1. Backing into parking lot not advisable with the number of parking spaces identified. DS 6-01.4.1.I Recommend positioning enclosure by flipping the current design so that the enclosure is centered at the eastend of the parking lot (where the plan currently shows service vehicle backing into). The service vehicle can then use the current placement of the enclosure as a lane for backing into and pull forward to exit. Please correct with resubmittal. |
| 07/06/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES July 6, 2007 Steve Wollerman Southwestern Consulting Engineers, LLC 435 East 9th Street Tucson, Arizona 85705 Subject: D06-0043 Camino De Café Lot 18 Development Plan Dear Steve: Your submittal of May 30, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Development Plan (ESD, Zoning, DSD) 2 Copies Revised Landscape Plan (Zoning, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 628-1063 |