Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D06-0042
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/28/2007 | CDRC1 | PIMA COUNTY | WASTEWATER | Approved | June 28, 2007 To: Wayne Royce, Urban Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ____________________________________ From: Tom Porter (520-740-6579), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: Rita Ranch Commerce Centre Lot #34 Development Plan - 3rd Submittal D06-0042 The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan as submitted. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 07/03/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Approv-Cond | 2. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. The future SVT's must also be shown. The FOC is 10' from the future right-of-way. 3. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. Per previous comment. 4. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. The future face of curb is 10' in from the future right-of-way line. Dimension the future sidewalk area. 5. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. There seems to be a discrepancy between the basis of bearing in the "Survey Notes" and the "Horizontal and Vertical control……Points". Revise as necessary. |
| 07/17/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D06-0042 Rita Ranch Commerce Centre Development Plan Resubmittal TRANSMITTAL DATE: July 13, 2007 DUE DATE: July 24, 2007 COMMENTS: The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 1. Correct the number of required van accessible spaces from "every 8" to "every 6" under Development Criteria 7 If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D06-042dpr1.doc |
| 07/18/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | 1) A vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from extending beyond the property lines; damaging adjacent landscaping, walls, or buildings and to prevent vehicles from driving onto unimproved portions of the site. DS 3-05.2.3.C. Revise the plans as necessary to include a sufficient barrier at the edge of the paved area at the northeast portion of the site at the perimeter of the repair stalls or whever the pavement terminates. The response letter indicates that a wall is proposed. Show any proposed walls on the development and landscape plans. |
| 07/31/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 08/22/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 22, 2007 Wayne A. Royce Urban Engineering 877 South Alvernon Way Suite 200 Tucson, Arizona 85705 Subject: S06-0042 Rita Ranch Commerce Center Development Plan Dear Wayne: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line comments, please submit the following documents for sign-off. 1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). AND 1 Double Matte right-reading Océ or Photo Mylar of the Development Plan. AND 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 318-3808 dpapproved |