Permit Number: D06-0033
Parcel: 13110034A

Address:
5500 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D06-0033
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2007 PAUL MACHADO ENGINEERING REVIEW Approved
01/05/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

January 5, 2007

Maolin Zheng
BSW International Inc.,
3420 East Shea Blvd., Suite 200
Tucson, Arizona 85023

Subject: D06-0033 Walmart Neighborhood Market Development Plan

Dear Maolin:

Your submittal of November 13, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Development Plan (Zoning, DSD )

2 Copies Revised Landscape Plan (Zoning, DSD)




Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (602)953-5106
dp-resubmittal
11/09/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
11/20/2006 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
11/28/2006 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond 1) Landscape borders proposed in right-of-way or MS&R areas must be approved by the City Engineer or designee and comply with the City Engineer's requirements on construction, irrigation, location, and plant type.

Provide verification, in writing, of any approvals obtained. Contact Gary Wittwer, DOT Landscape Architect for specific requirements.

RESUBMITTAL OF ANY REVISED PLANS IS REQUIRED.
SUBMIT APPROVAL FROM CITY ENGINEER FOR LANDSCAPING IN THE PUBLIC RIGHT-OF-WAY.
11/29/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D06-0033 WALMART NEIGHBORHOOD MARKET/REVISED DEVELOPMENT PLAN
DATE: 11/29/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.



ES
11/30/2006 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: D06-0033
Walmart Neighborhood Market
Development Plan Resubmittal

TRANSMITTAL DATE: November 30, 2006

DUE DATE: December 11, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please correct spelling in general note 19 : "This project is designed ti (change to "to") meet the overlay zone criteria of Sec. 2.8.1, Major Streets and Routes (MS&R) Setback Zone".

2. Please provide widths of curbs for Twenty-second Street, Craycroft Road, Jefferson Avenue, and Juarez Street on the development plan (DP).
DS 2-05.2.3.C

3. Multiple rack bicycle parking require a minimum thirty (30 inches between outer spaces of posts or racks (DS 2-09.5.1.A). Please review revised DS 2-09.8.0 Figure 9 and provide the necessary corrections to the bicycle parking on the plan view and detail as required.
DS 2-09.5.1.A & DS 2-09.8.0 Figure 9

4. Please delineate those parking spaces abutting cart corrals as being ten (10) feet wide on the plan, either by keynote or dimension. Please dimension the space between the parking space and the dumpster in southwest portion of the site behind vacant building 5504.
DS 3-05.2.1.B.3

5. Please dimension the drive-through lane. The minimum lane width leading to the drive through window is eleven (11) feet and must be clearly marked. The minimum drive-through lane width at the window is nine (9) feet. No more than two car lengths may be less than the minimum width of eleven (11) feet. A minimum distance of one (1) foot must be maintained between a structure and the drive-through lane
DS 3-05.2.1.C.2.a & DS 3-05.2.2.B.4

6. Key note 19 does not address truncated domes. Detectable warnings (truncated domes) are required at marked crossings (crosswalks). The area covered by the truncated domes shall be twenty-four (24) inch deep and extend the full width of the crosswalk, preceding the crosswalk, including the handicap access aisle.

The flush entrance into the grocery from the PAAL shall have truncated domes installed that shall be twenty-four (24) inches minimum in the direction of travel and extend the full width of the flush surface. The domes shall be located so the edge nearest the curb line is six (6) inches to eight (8) inches from the curb line. Please provide.
ANSI 406.12, ANSI 705


If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\developmentplan\D06-0033dpr.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan.
12/08/2006 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approved PIMA COUNTY WASTEWATER
December 7, 2006

TO: Maolin Zheng
BSW International, Inc.

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: R S Engineering (Contract Reviewer)
Chandubhai Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Wal-Mart Neighborhood Market #4603-00
Development Plan - 2nd Submittal
D06-0033

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

1. The comments of the letter of September 19, 2006 have been satisfied; therefore this project is approved as submitted.

Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval to Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality active permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Michael J. Harrington, Sr. CEA
Telephone: (520) 740-6579

Copy: RSE Job # 0432.05.4